-
SIEMENS
-
ABB
-
EMERSON
-
SCHNEIDER
-
OMRON
-
PEPPERL+FUCHS
-
MTL
-
ROCKWELL AUTOMATION
-
HIRSCHMANN
-
GE
-
WEIDMULLER
-
WIKA
-
YOKOGAWA
- ▶ Pressure Transmitter EJA
- ▪ EJA110A
- ▪ EJA115
- ▪ EJA118W/EJA118N
- ▪ EJA120A
- ▪ EJA130A
- ▪ EJA210A/EJA220A
- ▪ EJA310A
- ▪ EJA430A
- ▪ EJA438W/EJA438N
- ▪ EJA440A
- ▪ EJA510A/EJA530A
- ▶ Pressue Transmitter EJX
- ▪ EJX110A
- ▪ EJX115A
- ▪ EJX118A
- ▪ EJX120A
- ▪ EJX130A
- ▪ EJX210A
- ▪ EJX310A
- ▪ EJX430A
- ▪ EJX438A
- ▪ EJX440A
- ▪ EJX510A
- ▪ EJX530A
- ▪ EJX610A
- ▪ EJX630A
- ▪ EJX910A
- ▪ EJX930A
- ▶ Magnetic Flowmeters
- ▪ ADMAG AXF Remote Flowtube
- ▪ AXFA14 Converter
- ▪ AXFA11 Converter
- ▪ ADMAG AXF Integral Flowmeter
- ▪ ADMAG AXW Magnetic Flowmeters
- ▪ ADMAG AXR Two-wire Magnetic Flowmeters
- ▪ ADMAG CA Series Capacitance Magnetic Flowmeters
- ▶ Vortex Flowmeter
- ▪ digitalYEWFLO Vortex Flowmeter (DY)
- ▪ digitalYEWFLO Reduced Bore Type Vortex Flowmeter (DY-RB)
- ▪ digitalYEWFLO Multivariable Type Vortex Flowmeter (DY-MV)
- ▪ digitalYEWFLO Vortex Flowmeter High process Temperature Version / Cryogenic Version (DY-HTLT)
- ▪ digitalYEWFLO Fieldbus Type Vortex Flowmeter (DY-FF)
- ▶ Ultrasonic Flowmeters
- ▪ US300PM Ultrasonic Flowmeter (Portable type)
- ▪ US300FM Ultrasonic Flowmeter (fixed type)
- ▶ Variable Area Flowmeters – Rotameters
- ▪ Variable Area Flowmeter-RAMC (Metal Short-stroke Rotameter)
- ▪ Variable Area Flowmeter-RAKD (Small Metal Rotameter)
- ▪ Model RAGN Rotameter
- ▪ Model RAGK/RAGL Rotameter
- ▶ PORTABLE AND HANDHELD INSTRUMENTS
- ▪ HANDY CALIBRATOR CA11E
- ▪ CA700 Pressure Calibrator
- ▪ HANDY TEMPERATURE CALIBRATOR CA12E
- ▪ HANDY MULTIFUNCTION CALIBRATOR CA71
- ▪ Yokogawa CA450 Process Multimeter
- ▪ HANDY CALIBRATOR CA150
-
WATSON SMITH
-
METRIX
-
ASCO
-
ENDRESS+HAUSER
-
BENTLY NEVADA
-
HACH
-
NORGREN
-
HONEYWELL
-
TESTO
-
PHOENIX CONTACT
-
SICK
-
DANFOSS
-
CISCO
-
IFM
-
KROHNE
-
ROSEMOUNT
-
FISHER
-
YOKOGAWA DIGITAL INSULATION TESTER MY40-01
INSULATION TESTER ACCESSORIES Model Description 98007 Earth and Line Probe for 2406 B9646CA Test Lead Storage Bag (3213) B9600HA Case for 3213 321803 Lead for Terminal Guard (2406E; 3213A) B9600NZ Probe Tip Pointed #5 B9600NX Probe Tip Extension #3 B9600GN General Purpose Probe #1 B9600NV Probe Tip Storage Bag 98050 Line Probe and Earth Probe (3213A) 98002 My-Earth Probe B9075MU Hard Case with Probe Case (2406D & E) 99005 My-Shoulder Strap 93013 My-Protection Cover 98001 My-Line Probe
Digital model with 4 voltage/resistance ratings Multifunction Insulation resistance, AC voltage and conductor resistance measurement Insulation test mode: Comparator, memory, auto-hold and discharge functions All test modes: Live-line alarm (excluding AC voltage measurement), battery check and automatic power-off ...
-
DIGITAL INSULATION TESTER MY40
INSULATION TESTER ACCESSORIES Model Description 98007 Earth and Line Probe for 2406 B9646CA Test Lead Storage Bag (3213) B9600HA Case for 3213 321803 Lead for Terminal Guard (2406E; 3213A) B9600NZ Probe Tip Pointed #5 B9600NX Probe Tip Extension #3 B9600GN General Purpose Probe #1 B9600NV Probe Tip Storage Bag 98050 Line Probe and Earth Probe (3213A) 98002 My-Earth Probe B9075MU Hard Case with Probe Case (2406D & E) 99005 My-Shoulder Strap 93013 My-Protection Cover 98001 My-Line Probe
Digital model with 4 voltage/resistance ratings Multifunction Insulation resistance, AC voltage and conductor resistance measurement Insulation test mode: Comparator, memory, auto-hold and discharge functions All test modes: Live-line alarm (excluding AC voltage measurement), battery check and automatic power-off ...
-
GE IC693ACC302 Auxiliary Battery Module
MANUFACTURER: GE-IP DESCRIPTION: HIGH CAPACITY BATTERY PACK WEIGHT: 1 LBS :: ≈ 1 KGS WARRANTY: 1 YEARS PRODUCT REVISIONS AVAILABLE: OTHER AVAILABLE REVISIONS OF THE IC693ACC302 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z
Auxiliary Battery Module IC693ACC302 GFK-2124A for Series 90 and PACSystems April 2005 The optional IC693ACC302 Auxiliary Battery Module provides an extended memory backup time compared to that of the standard memory backup batteries for Series 90-30, Series 90-70, and PACSystems CPUs. The Auxiliary Battery Module repl...
-
GE IC693ACC300 Input Simulator Module
The Input Simulator module does not require any field wiring - just set the mode switch on the back of the module to 8 or 16 and install the module in the selected I/O slot in a baseplate. An illustration of the module is shown in the following figure.
MANUFACTURER: GE-IP DESCRIPTION: 9030 16 PT SIMULATOR INPUT MODULE WEIGHT: 1 LBS :: ≈ 1 KGS WARRANTY: 1 YEARS PRODUCT REVISIONS AVAILABLE: OTHER AVAILABLE REVISIONS OF THE IC693ACC300 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z,
-
EJA110A-DMH5A-92NN Yokgoawa differential pressure transmitter
The high performance differential pressure transmitter model EJA110A can be used to measure liquid, gas, or steam flow as well as liquid level, density and pressure. It outputs a 4 to 20 mA DC signal corresponding to the measured differential pressure. Model EJA110A also features remote setup and monitoring thro...
-
EJA110A-DMH5A-92NN Yokgoawa differential pressure transmitter
The high performance differential pressure transmitter model EJA110A can be used to measure liquid, gas, or steam flow as well as liquid level, density and pressure. It outputs a 4 to 20 mA DC signal corresponding to the measured differential pressure. Model EJA110A also features remote setup and monitoring thro...
-
Yokogawa PH450G-D-A/UM
Unique touch screen operation with menu structure in 5 languages Dual High Impedance Capability, allowing for Differential pH/ORP measurements Enhanced diagnostics, process trending graphics andon-screen logbooks for data storage Two mA-outputs and four SPDT relay contacts with display indicators Hart® Communications FM Class 1, Div.2, Group ABCD, T6 for Ta-20 to 55°C IP66/NEMA4X 1/2 DIN enclosure for Field Mounting and Panel Mounting Three sets of preloaded pH buffer standards (NIST, US and DIN)
The new EXAxt 450 series builds on the superior functionality of the industry leading Yokogawa EXA series by enhancing the EXA's proven operation and application flexibility. The Model 450 series feature a uniquely simple touch screen menu structure that offers a choice of multiple languages. The Model PH450 provide...
-
Yokogawa PH450G-A-A/UM/SCT
Unique touch screen operation with menu structure in 5 languages Dual High Impedance Capability, allowing for Differential pH/ORP measurements Enhanced diagnostics, process trending graphics andon-screen logbooks for data storage Two mA-outputs and four SPDT relay contacts with display indicators Hart® Communications FM Class 1, Div.2, Group ABCD, T6 for Ta-20 to 55°C IP66/NEMA4X 1/2 DIN enclosure for Field Mounting and Panel Mounting Three sets of preloaded pH buffer standards (NIST, US and DIN)
The new EXAxt 450 series builds on the superior functionality of the industry leading Yokogawa EXA series by enhancing the EXA's proven operation and application flexibility. The Model 450 series feature a uniquely simple touch screen menu structure that offers a choice of multiple languages. The Model PH450 provide...
-
Yokogawa PH450G-A-A/PM/ANSI/SCT
Unique touch screen operation with menu structure in 5 languages Dual High Impedance Capability, allowing for Differential pH/ORP measurements Enhanced diagnostics, process trending graphics andon-screen logbooks for data storage Two mA-outputs and four SPDT relay contacts with display indicators Hart® Communications FM Class 1, Div.2, Group ABCD, T6 for Ta-20 to 55°C IP66/NEMA4X 1/2 DIN enclosure for Field Mounting and Panel Mounting Three sets of preloaded pH buffer standards (NIST, US and DIN)
The new EXAxt 450 series builds on the superior functionality of the industry leading Yokogawa EXA series by enhancing the EXA's proven operation and application flexibility. The Model 450 series feature a uniquely simple touch screen menu structure that offers a choice of multiple languages. The Model PH450 provide...
-
Yokogawa FLXA21-D-P-D-AA-P1-NN-A-N-LA-N-NN/U
One analyzer can accept any of 4 types of measurements; pH/ORP, Contacting Conductivity (SC), Inductive Conductivity (ISC) and Dissolved Oxygen (DO) Dual sensor measurement on a 2-wire type analyzer pH/ORP and pH/ORP, SC and SC, and DO and DO Modular design: replaceable sensor modules Redundant system on dual sensor measurement Variety of materials of construction: SS or Plastic Intuitive easy touch screen operation on 2-wire type analyzer Unique HMI menu structure in 12 languages Quick setup menu for fast and east measurement operation Online Sensor Wellness checking for predictive maintenance NEMA 4X / IP66 Enclosure
The model FLEXA® two-wire analyzer is used for continuous on-line measurements in industrial installations. It offers an option for single or dual sensor measurement, making it the most flexible 2-wire analyzer available. The model FLEXA® modular-designed series analyzer offers 4 parameter choices – pH/ORP (oxidation-r...