Liquid Density Analyzer-DM8C/VD6
2016-05-27 15:18:47
Description:
The DM8 liquid density analyzer measures liquid density of general process liquids with high sensitivity and excellent stability. It has a measuring density range of 0 to 2.0 g/cm3, and unaffected by flow rate and viscosity. Besides general-purpose sensor, sanitary and explosionproof sensor are also available. The DM8 is a vibration type liquid density analyzer and its converter incorporates a microprocessor to directly convert frequency signals from the sensor into density values and display them and is provided with a variety of functions such as one-touch calibration, self diagnosis, digital output.……
New Products
OMRON CS1W-CN133 CS1 I/O Connecting Cable
OMRON CS1W-CN133 CS1 I/O Connecting Cable. Connects CS1 Expansion I/O Backplanes to CPU Backplanes or other CS1 Expansion I/O Backplanes.
OMRON CS1W-AD041-V1 CS1W series Analog Input Unit
OMRON CS1W-AD041-V1 CS1W series Analog Input Unit. Contact us to learn more about the OMRON CS1G/CS1H/CS1W/CS1D SYSMAC CS1 Programmable Controller.
OMRON CS1H-CPU63H CS1H CPU Unit
OMRON CS1H-CPU63H CS1H CPU Unit. Omron CS1 Series is widely used in industrial automation applications such as production line control, process monitoring, packaging, material handling, and power plant systems.
OMRON CS1G-CPU42H CS1G CPU Unit
OMRON CS1G-CPU42H CS1G CPU Unit. Ideal for control of power generators, water supply utilities, 24/7 production.
Assortments
▶ Pressure Transmitter EJA
▶ Pressure Transmitters EJA-E
▶ Pressue Transmitter EJX
▶ Safety Instrumented System (SIS)
▶ Valve Positioners & Converters
▶ Field Mount Indicators
▶ Temperature Transmitters
▶ Magnetic Flowmeters
▶ Vortex Flowmeter
▶ Ultrasonic Flowmeters
▶ Coriolis Mass Flowmeters - ROTAMASS 3-Series
▶ Variable Area Flowmeters – Rotameters
▶ Device Smart Communicators
▶ PORTABLE AND HANDHELD INSTRUMENTS
▶ Distributed Control System (DCS)
▶ Process Analyzers
▶ Paperless Recorders
▶ Strip Chart Recorders
▶ Data Acquisition Equipment
▶ UT Series Temperature Controllers
▶ UP Series Program Controllers
▶ UM Series Digital Indicators with Alarms
▶ UT100 Series Temperature Controllers
▶ UD Series Manual Setters
▶ Limit Controllers
▶ YS Series Single-loop Controllers
Description
DM8C/VD6
In 1967, Yokogawa developed the model VD6 vibration type liquid density analyzer in response to user requests for an online density analyzer that could be used in process automation. This was an important development in the instrumentation field, because density is a fundamental physical quantity, and its accurate measurement is important to almost all processes. The VD6 density analyzer has gone on to develop an excellent reputation as a highly stable, high sensitivity meter.
The new DM8 vibration type liquid density analyzer is a highly reliable, multi-function meter that builds on the experience gained with the VD6. It takes advantage of the latest computer technology to integrate a wide range of sensor techniques. Its converter incorporates a microprocessor that directly converts sensor frequency signals into density values for display. It is provided with a variety of functions such as one-touch calibration, self diagnosis and digital output (RS-232C).
The DM8 is a vibration type liquid density analyzer and its converter incorporates a microprocessor to directly convert frequency signals from the sensor into density values and display them and is provided with a variety of functions such as one-touch calibration, self diagnosis, digital output.
The DM8 liquid density analyzer measures liquid density of general process liquids with high sensitivity and excellent stability. It has a measuring density range of 0 to 2.0 g/cm3, and unaffected by flow rate and viscosity. Besides general-purpose sensor, sanitary and explosionproof sensor are also available.
High sensitivity and stability.
One touch calibration with a standard calibrating solution.
Free setting of measuring range in the field.
Failure alarm display and output.
Outdoor installation of converter.
| Measurement object | Liquid density |
|---|---|
| Measurement principle | Vibration density measurement |
| Measurement range | Density :0.5 to 2.0 g/cm3 |
| Measuring liquid temperature | -10 to 100℃ |
| Measuring liquid pressure | 2 MPa G or less |
| Withstandable pressure | 4.9 MPa G |
| Output signal | Analog output:4 to 20 mA DC (load resistance 550 Ω or less), and 0 to 1 V DC (load resistance 250 kΩ or more), isolated output. Digital output: RS-232C |
| Output signal span | 0.05 to 0.5 g/cm3 settable |
| Reference temperature set range | 0 to 100℃ (in increments or decrements of 1℃) |
| Contact output on failure | One output |
| Settable range for temperature coefficient | 0 to 0.002 g/cm3/℃ |
| Calibration procedure | One-touch calibration by strong calibration liquid density (one-point calibration) |
| Ambient temperature | -10 to 55℃ |
| Case construction | Dust and rain proof construction |
| Power supply | 90 to 132 V AC or 180 to 264 V AC, 50/60 Hz |
| Weight | Approx. 7.5 kg (Converter), approx. 12.0 kg (Detector) |
| Linearity | ±0.5 % of span (when span is 0.2 g/cm3 or less) |
|---|---|
| Repeatability | 5 x 10-4 g/cm3 (for digital output) 1 % of span (for analog output) |