Profibus Conductivity Transmitter/Analyzers
2016-05-27 13:13:11
Description:
PROFIBUS is an open, digital communication system which covers factory and process automation. These analyzers are designed for 2-wire (loop powered) system configuration with PROFIBUS communication.……
New Products
FXT1-P37 Right Angle Milling Head
FXT1-P37 Right Angle Milling Head - HKXYTECH
FXT1-P24 Right Angle Milling Head
FXT1-P24 Right Angle Milling Head - HKXYTECH
FXT1-P18 Right Angle Milling Head
FXT1-P18 Right Angle Milling Head - HKXYTECH
FXT1-AC Fully Automatic Right Angle Milling Heads
FXT1-AC Fully Automatic Right Angle Milling Heads - HKXYTECH
Assortments
▶ Pressure Transmitter EJA
▶ Pressure Transmitters EJA-E
▶ Pressue Transmitter EJX
▶ Safety Instrumented System (SIS)
▶ Valve Positioners & Converters
▶ Field Mount Indicators
▶ Temperature Transmitters
▶ Magnetic Flowmeters
▶ Vortex Flowmeter
▶ Ultrasonic Flowmeters
▶ Coriolis Mass Flowmeters - ROTAMASS 3-Series
▶ Variable Area Flowmeters – Rotameters
▶ Device Smart Communicators
▶ PORTABLE AND HANDHELD INSTRUMENTS
▶ Distributed Control System (DCS)
▶ Process Analyzers
▶ Paperless Recorders
▶ Strip Chart Recorders
▶ Data Acquisition Equipment
▶ UT Series Temperature Controllers
▶ UP Series Program Controllers
▶ UM Series Digital Indicators with Alarms
▶ UT100 Series Temperature Controllers
▶ UD Series Manual Setters
▶ Limit Controllers
▶ YS Series Single-loop Controllers
Description
Profibus Conductivity Transmitter/Analyzers
PROFIBUS is an open, digital communication system which covers factory and process automation. These analyzers are designed for 2-wire (loop powered) system configuration with PROFIBUS communication.
Model Code | FLXA21-D-P-D-AA-C1-NN-P | Not available at this time | FLXA21-D-P-D-AA-C5-NN-P | Not available at this time |
---|---|---|---|---|
Area Classification | General Purpose |
| General Purpose |
|
Measurement Type | Contacting Conductivity, Resistivity | Inductive, Torodial, Non-Contacting Conductivity | ||
Enclosure Material | Plastic (Polycarbonate) |
Flexibility, reliability and low maintenance are among the benefits provided by the FLXA21 conductivity analyzer. Designed to meet the particular requirements of measuring conductivity and resistivity in the modern industrial environment, it contains many features to ensure the best precision whatever the application.
The transmitter is housed in a robust IP66 field mountable case and combined with the easy and clear LCD makes the FLXA21 a complete industrial transmitter. The logbook can be used to record events like calibrations and diagnostic messages. A wide variety of temperature compensation possibilities (NaCl according to IEC 746-3, manual TC, preprogrammed matrices and a free programmable 5x5 matrix), provide a high-accuracy measurement with a minimum effort. The addition of a USP23 pure water monitoring feature also makes the FLXA21 suitable for the pharmaceutical industry.
Yokogawa has implemented three leading process Fieldbus technologies in their FLXA21 series: HART, Foundation Fieldbus H1 and Profibus PA. All transmitters are provided with the important and widely used Device Description files that provide information on parameters and other data in each device, as well as the ability to include algorithmic relationships such as calibrations.
Universal conductivity/resistivity, software switchable
On-line sensor checking
Event logbook in software
Matrix temperature compensation for pure water applications
Password protection for all levels of software
Intrinsically safe version and non-incendive versions
Pharmaceutical pure water monitoring (USP23)
Autoranging from 0.01 µSxC.C to 200mSxC.C.
HART, Foundation Fieldbus, or Profibus Communications options
Extremely wide measuring range (> 6 decades) while maintaining a high resolution and accuracy using only one sensor type.
Free programmable setting of the output range, including a 21-step table output to linearize the output function e.g. to % by weight.
Programmable % by weight display indication.
Can be password protected
Input specifications | Two or four electrode measurement with square wave excitation. |
---|---|
Detection method | Frequency, read-pulse position and reference voltage are dynamically optimized. |
Input ranges | Conductivity: Minimum: 0 μS/cm Maximum: 200 mS x C (overrange 1999 mS/cm). Resistivity: Minimum: 0.005 kΩ/C Maximum: 999 MΩ x cm Temperature: Pt1000: -20 to 250°C (0 to 500°F) Pt100 and Ni100: -20 to 200°C (0 to 400°F) 8k55 NTC: -10 to 120°C (10 to 250°F) PB36 NTC: -20 to 120°C (0 to 250°F) |
Contacting Conductivity | Accuracy: ±0.5 % F.S. (1 μS x K cm-1 to 200 mS x K cm-1); Accuracy: ±1 % F.S. (1 μS x K cm-1 to 2 μS x K cm-1) |
Resistivity | Accuracy: ±0.5 % F.S. (0.005 kΩ/K cm-1 to 0.5 MΩ/K cm-1); Accuracy: ±7 % F.S. (0.5 MΩ/K cm-1 to 1 MΩ/K cm-1) |
Temperature | Accuracy: ±0.3°C (Pt1000, PB36NTC, Ni100); Accuracy: ±0.4°C (Pt100, NTC8k55) |
Inductive Conductivity | Output span is 0-100 μS or more Linearity±(0.4 % FS + 0.3 μS/cm) Repeatability±(0.4 % FS + 0.3 μS/cm) |
Step Response | ≤8 seconds for 90 % (for 2 decade step) |
Output Span | Conductivity: Min. 0.01 μS/cm, Max. 1999 mS/cm. (Max 90 % zero suppression) Resistivity: Min. 0.001 kΩ x cm, Max. 999 MΩ x cm. (Max 90 % zero suppression) |
Transmission Signals | Isolated output of 4 to 20 mA DC. Burn up (21 mA) or Burn down (3.6 mA when HART or distributor comm. is non-used, 3.9 mA when HART or distributor comm. is used) or pulse of 21 mA to signal failure. |
Temperature compensation | Automatic, for temperature ranges Reference temp.: programmable from 0 to 100°C or 30 to 210°F (default 25°C). |
Compensation algorithm | Automatic, for temperature ranges NaCl according to IEC 60746-3 tables. |
Communications | PROFIBUS-PA |
Ambient temperature | -20 to 50 °C |
Humidity | 10 to 90 % RH (Non-condensing) |
Display | Black/White 213 x 160 pixels LCD with touch screen |
Power supply | Nominal 24 volt DC loop powered system. |