Dual-Channel Conductivity Analyzer FLXA21, FLXA202, DC402G
2016-05-27 12:54:49
Description:
Dual-Channel Conductivity Analyzer FLXA21, FLXA202, DC402G……
New Products
FXT1-P37 Right Angle Milling Head
FXT1-P37 Right Angle Milling Head - HKXYTECH
FXT1-P24 Right Angle Milling Head
FXT1-P24 Right Angle Milling Head - HKXYTECH
FXT1-P18 Right Angle Milling Head
FXT1-P18 Right Angle Milling Head - HKXYTECH
FXT1-AC Fully Automatic Right Angle Milling Heads
FXT1-AC Fully Automatic Right Angle Milling Heads - HKXYTECH
Assortments
▶ Pressure Transmitter EJA
▶ Pressure Transmitters EJA-E
▶ Pressue Transmitter EJX
▶ Safety Instrumented System (SIS)
▶ Valve Positioners & Converters
▶ Field Mount Indicators
▶ Temperature Transmitters
▶ Magnetic Flowmeters
▶ Vortex Flowmeter
▶ Ultrasonic Flowmeters
▶ Coriolis Mass Flowmeters - ROTAMASS 3-Series
▶ Variable Area Flowmeters – Rotameters
▶ Device Smart Communicators
▶ PORTABLE AND HANDHELD INSTRUMENTS
▶ Distributed Control System (DCS)
▶ Process Analyzers
▶ Paperless Recorders
▶ Strip Chart Recorders
▶ Data Acquisition Equipment
▶ UT Series Temperature Controllers
▶ UP Series Program Controllers
▶ UM Series Digital Indicators with Alarms
▶ UT100 Series Temperature Controllers
▶ UD Series Manual Setters
▶ Limit Controllers
▶ YS Series Single-loop Controllers
Description
Dual-Channel Conductivity Analyzer
Model Code | FLXA21 | FLXA202 | DC402G |
---|---|---|---|
Area Classification |
|
|
|
Enclosure Material | Plastic (Polycarbonate) | Aluminum alloy die cast with epoxy coating (Standard offering) Aluminum alloy die cast with urethane or high anti corrosion coating (available upon request) | Cast Aluminum with chemically resistance coating; polycarbonate cover with polycarbonate flexible window |
Housing Rating | IP66/ NEMA 4A/ CSA 3S | IP66 (except Canada), Type 4X (except Canada), Type 3S/4X (Canada) | IP66/ NEMA 4A/ CSA 3S |
Power Supply | 2-wire 24VDC, Loop Powered | 2-wire 24VDC, Loop Powered | 4-Wire 110-256 VAC, Mains Power |
Output Signal | Bi-directional HART digital communication, superimposed on mA (4-20mA) signal. | Bi-directional HART digital communication, superimposed on mA (4-20mA) signal. | Two isolated outputs of 4 to 20 mA DC with common negative. |
The model FLEXA® two-wire analyzer is used for continuous on-line measurements in industrial installations. It offers an option for single or dual sensor measurement, making it the most flexible 2-wire analyzer available. The model FLEXA® modular-designed series analyzer.
One analyzer can accept any of 4 types of measurements; pH/ORP, Contacting Conductivity (SC), Inductive Conductivity (ISC) and Dissolved Oxygen (DO)
Dual sensor measurement on a 2-wire type analyzer pH/ORP and pH/ORP, SC and SC, and DO and DO
Modular design: replaceable sensor modules
Redundant system on dual sensor measurement
Variety of materials of construction: SS or Plastic
Intuitive easy touch screen operation on 2-wire type analyzer
Unique HMI menu structure in 12 languages
Quick setup menu for fast and east measurement operation
Online Sensor Wellness checking for predictive maintenance
NEMA 4X / IP66 Enclosure
Input Specification | Two or four electrode measurement with square wave excitation, using max. 60 m cable and cell constants from 0.005 to 50.0 cm-1 |
---|---|
Input Range | Conductivity: 0 to 2000 mS/cm at 25ºC (77°F) Temperature: -20 to 140ºC (0 to 280°F) |
Conductivity | 2 µS x K cm-1 to 200 mS x K cm-1 Accuracy: ±0.5% F.S. 1 µS x K cm-1 to 2 µS x K cm-1 Accuracy: ±1% F.S. |
Resistivity | 0.005kΩ/ K cm-1 to 0.5MΩ/ K cm-1 Accuracy: ±0.5% F.S. 0.5MΩ/ x K cm-1 to 1MΩ/ x K cm-1 Accuracy: ±1% F.S. |
Temperature | with Pt1000, Pb36, Ni 100 Accuracy: ± 0.3ºC with Pt100, NTC 8k55 Accuracy: ± 0.4ºC |
Step Response | ≤7 seconds for 90% (for a 2 decade step) |
Cable Length | Max 60 meters (200 feet). 10 meters (35 feets0 fixed sensor cable + 50 meters (165 feet) WF10 extension cable |
Transmission Signal | Bi-directional HART digital communication, superimposed on mA (4-20 mA) signal |
Temperature Compensation | Automatic or manual, for temperature ranges. Reference temp. programmable from 0-100°C or 30-210°F (default 25°C) |
Calibration | Semi-automatic calibration using pre-configured OIML (KCl) standard tables, with automatic stability check. Manual adjustment to grab sample. |
Display | Black and white, 213 x 160 pixels LCD with a touch screen |
Housing | IP66/ NEMA 4A/ CSA 3S IP66 (except Canada), Type 4X (except Canada), Type 3S/4X (Canada) |
Environment | Ambient Temperature: -20 to 55°C Humidity: 10 to 90% RH at 40°C (non-condensing) |
Power Supply | Ratings; 17 to 40 V DC |