Dual-Channel Conductivity Analyzer FLXA21, FLXA202, DC402G
2016-05-27 12:54:49
Description:
Dual-Channel Conductivity Analyzer FLXA21, FLXA202, DC402G……
New Products
Orbinox VG SERIES 61 Slurry knife gate valve
Orbinox SERIES 61 (VG) model knife gate valve is a wafer type valve equipped with two metal reinforced rubber sleeves,designed for applications with abrasive slurries.
Crosby J-Series Direct Spring Pressure Relief Valves
J-Series valves provide high quality and dependable overpressure protection for air, gas, steam, vapor, liquid and two-phase applications in one simple design. Now available with two new to the world technologies, Balanced Diaphragm and Bellows Leak Detection.
Vanessa Series 30,000 Cryogenic Triple Offset Valve
The Vanessa Series 30,000 Cryogenic Triple Offset Valve is a virtually maintenance-free valve with tightness, operability and torque demand unaffected by cryogenic conditions and severe temperature fluctuations.
Sempell Model SOT High pressure steam safety valve
The Sempell Model SOT is a high-pressure steam safety valve designed for boiler protection and steam system safety.
Assortments
▶ Pressure Transmitter EJA
▶ Pressure Transmitters EJA-E
▶ Pressue Transmitter EJX
▶ Safety Instrumented System (SIS)
▶ Valve Positioners & Converters
▶ Field Mount Indicators
▶ Temperature Transmitters
▶ Magnetic Flowmeters
▶ Vortex Flowmeter
▶ Ultrasonic Flowmeters
▶ Coriolis Mass Flowmeters - ROTAMASS 3-Series
▶ Variable Area Flowmeters – Rotameters
▶ Device Smart Communicators
▶ PORTABLE AND HANDHELD INSTRUMENTS
▶ Distributed Control System (DCS)
▶ Process Analyzers
▶ Paperless Recorders
▶ Strip Chart Recorders
▶ Data Acquisition Equipment
▶ UT Series Temperature Controllers
▶ UP Series Program Controllers
▶ UM Series Digital Indicators with Alarms
▶ UT100 Series Temperature Controllers
▶ UD Series Manual Setters
▶ Limit Controllers
▶ YS Series Single-loop Controllers
Description
Dual-Channel Conductivity Analyzer
Model Code | FLXA21 | FLXA202 | DC402G |
---|---|---|---|
Area Classification |
|
|
|
Enclosure Material | Plastic (Polycarbonate) | Aluminum alloy die cast with epoxy coating (Standard offering) Aluminum alloy die cast with urethane or high anti corrosion coating (available upon request) | Cast Aluminum with chemically resistance coating; polycarbonate cover with polycarbonate flexible window |
Housing Rating | IP66/ NEMA 4A/ CSA 3S | IP66 (except Canada), Type 4X (except Canada), Type 3S/4X (Canada) | IP66/ NEMA 4A/ CSA 3S |
Power Supply | 2-wire 24VDC, Loop Powered | 2-wire 24VDC, Loop Powered | 4-Wire 110-256 VAC, Mains Power |
Output Signal | Bi-directional HART digital communication, superimposed on mA (4-20mA) signal. | Bi-directional HART digital communication, superimposed on mA (4-20mA) signal. | Two isolated outputs of 4 to 20 mA DC with common negative. |
The model FLEXA® two-wire analyzer is used for continuous on-line measurements in industrial installations. It offers an option for single or dual sensor measurement, making it the most flexible 2-wire analyzer available. The model FLEXA® modular-designed series analyzer.
One analyzer can accept any of 4 types of measurements; pH/ORP, Contacting Conductivity (SC), Inductive Conductivity (ISC) and Dissolved Oxygen (DO)
Dual sensor measurement on a 2-wire type analyzer pH/ORP and pH/ORP, SC and SC, and DO and DO
Modular design: replaceable sensor modules
Redundant system on dual sensor measurement
Variety of materials of construction: SS or Plastic
Intuitive easy touch screen operation on 2-wire type analyzer
Unique HMI menu structure in 12 languages
Quick setup menu for fast and east measurement operation
Online Sensor Wellness checking for predictive maintenance
NEMA 4X / IP66 Enclosure
Input Specification | Two or four electrode measurement with square wave excitation, using max. 60 m cable and cell constants from 0.005 to 50.0 cm-1 |
---|---|
Input Range | Conductivity: 0 to 2000 mS/cm at 25ºC (77°F) Temperature: -20 to 140ºC (0 to 280°F) |
Conductivity | 2 µS x K cm-1 to 200 mS x K cm-1 Accuracy: ±0.5% F.S. 1 µS x K cm-1 to 2 µS x K cm-1 Accuracy: ±1% F.S. |
Resistivity | 0.005kΩ/ K cm-1 to 0.5MΩ/ K cm-1 Accuracy: ±0.5% F.S. 0.5MΩ/ x K cm-1 to 1MΩ/ x K cm-1 Accuracy: ±1% F.S. |
Temperature | with Pt1000, Pb36, Ni 100 Accuracy: ± 0.3ºC with Pt100, NTC 8k55 Accuracy: ± 0.4ºC |
Step Response | ≤7 seconds for 90% (for a 2 decade step) |
Cable Length | Max 60 meters (200 feet). 10 meters (35 feets0 fixed sensor cable + 50 meters (165 feet) WF10 extension cable |
Transmission Signal | Bi-directional HART digital communication, superimposed on mA (4-20 mA) signal |
Temperature Compensation | Automatic or manual, for temperature ranges. Reference temp. programmable from 0-100°C or 30-210°F (default 25°C) |
Calibration | Semi-automatic calibration using pre-configured OIML (KCl) standard tables, with automatic stability check. Manual adjustment to grab sample. |
Display | Black and white, 213 x 160 pixels LCD with a touch screen |
Housing | IP66/ NEMA 4A/ CSA 3S IP66 (except Canada), Type 4X (except Canada), Type 3S/4X (Canada) |
Environment | Ambient Temperature: -20 to 55°C Humidity: 10 to 90% RH at 40°C (non-condensing) |
Power Supply | Ratings; 17 to 40 V DC |