Top Industrial Automation and Electrical Instrument from HKXYTECH
  • YOKOGAWA ANALOG TESTERS MY10 SERIES Model Model MY10-05

YOKOGAWA ANALOG TESTERS MY10 SERIES Model Model MY10-05

2016-05-24 01:30:47

Description:

Analog models with single rating MY10-01:125V/20MΩ MY10-02:250V/50MΩ MY10-03:500V/100MΩ MY10-04:500V/1000MΩ MY10-05:1000V/2000MΩ AC voltage measurement Automatic discharge A wide choice of accessories-Designed for shared use with the MY40……

Standard Accessories Batteries (Qty - 4) Earth Probe (98002) (Qty - 1) Line Probe (98001) (Qty - 1) Protection Cover (93013) (Qty - 1) Shoulder Strap (99005) (Qty - 1) User's Manual (Qty - 1)

Description

Specifications - Model MY10-01

Rating125V/20MΩ
Effective Measuring Range0.01-20MΩ
Central Scale Value0.5MΩ
AC Voltage Measurement0 to 250 V
Lower Limit0.125MΩ
Rated Current1-1.2 mA
Approx. Overall Scale Length107 mm
Battery LifeApprox. 10 hours when continuously operated on manganese - oxide batteries with the pointer pointing to the central scale value.
BatteriesFour AA (R6P) batteries
Approx. Width125 mm
Approx. Height103 mm
Approx. Depth53 mm
Approx. Weight500 g
ComplianceEN61010-1:1993; EN61010-2-31:1995 (Overvoltage Category III, Pollution Degree 2 installations for indoor use)
Standard AccessoriesBatteries (Qty - 4)
Earth Probe (98002) (Qty - 1)
Line Probe (98001) (Qty - 1)
Protection Cover (93013) (Qty - 1)
Shoulder Strap (99005) (Qty - 1)
User's Manual (Qty - 1)


Standard Test Conditions - Model MY10-01

Ambient Temperature/Humidity Ranges23 ±5 /45-75% RH
Position of UseHorizontal (5° max. of angle of inclination)
Battery VoltageWithin effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned ConditionsResistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.


Additional Functions - Model MY10-01

  • Automatic discharge function

    • If the object under test remains electrified after the MEAS switch is turned off, the tester lets you know by turning on the LED lamp. If you leave the tester connected to the electrified object, the tester automatically begins to discharge electricity and then finishes discharging-the LED lamp comes on and then goes out.

    • When the object under test is capacitive and electrified, the tester lets you know by turning on the LED lamp. When left connected to the object, the tester automatically discharges electricity, thus preventing possible electric shock or spike noise at power-on.

  • Battery check (BAT mark on the scale plate)

 

Specifications - Model MY10-02

Rating250V/50MΩ
Effective Measuring Range0.01-50MΩ
Central Scale Value1MΩ
AC Voltage Measurement0 to 300 V
Lower Limit0.25MΩ
Rated Current1-1.2 mA
Approx. Overall Scale Length107 mm
Battery LifeApprox. 10 hours when continuously operated on manganese - oxide batteries with the pointer pointing to the central scale value.
BatteriesFour AA (R6P) batteries
Approx. Width125 mm
Approx. Height103 mm
Approx. Depth53 mm
Approx. Weight500 g
ComplianceEN61010-1:1993; EN61010-2-31:1995 (Overvoltage Category III, Pollution Degree 2 installations for indoor use)
Standard AccessoriesBatteries (Qty - 4)
Earth Probe (98002) (Qty - 1)
Line Probe (98001) (Qty - 1)
Protection Cover (93013) (Qty - 1)
Shoulder Strap (99005) (Qty - 1)
User's Manual (Qty - 1)


Standard Test Conditions - Model MY10-02

Ambient Temperature/Humidity Ranges23 ±5 /45-75% RH
Position of UseHorizontal (5° max. of angle of inclination)
Battery VoltageWithin effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned ConditionsResistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.


Additional Functions - Model MY10-02

  • Automatic discharge function

    • If the object under test remains electrified after the MEAS switch is turned off, the tester lets you know by turning on the LED lamp. If you leave the tester connected to the electrified object, the tester automatically begins to discharge electricity and then finishes discharging-the LED lamp comes on and then goes out.

    • When the object under test is capacitive and electrified, the tester lets you know by turning on the LED lamp. When left connected to the object, the tester automatically discharges electricity, thus preventing possible electric shock or spike noise at power-on.

  • Battery check (BAT mark on the scale plate)

 

Specifications - Model MY10-03

Rating500V/100MΩ
Effective Measuring Range0.05-100MΩ
Central Scale Value2MΩ
AC Voltage Measurement0 to 500 V
Lower Limit0.5MΩ
Rated Current1-1.2 mA
Approx. Overall Scale Length107 mm
Battery LifeApprox. 10 hours when continuously operated on manganese - oxide batteries with the pointer pointing to the central scale value.
BatteriesFour AA (R6P) batteries
Approx. Width125 mm
Approx. Height103 mm
Approx. Depth53 mm
Approx. Weight500 g
ComplianceEN61010-1:1993; EN61010-2-31:1995 (Overvoltage Category III, Pollution Degree 2 installations for indoor use)
Standard AccessoriesBatteries (Qty - 4)
Earth Probe (98002) (Qty - 1)
Line Probe (98001) (Qty - 1)
Protection Cover (93013) (Qty - 1)
Shoulder Strap (99005) (Qty - 1)
User's Manual (Qty - 1)


Standard Test Conditions - Model MY10-03

Ambient Temperature/Humidity Ranges23 ±5 /45-75% RH
Position of UseHorizontal (5° max. of angle of inclination)
Battery VoltageWithin effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned ConditionsResistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.


Additional Functions - Model MY10-03

  • Automatic discharge function

    • If the object under test remains electrified after the MEAS switch is turned off, the tester lets you know by turning on the LED lamp. If you leave the tester connected to the electrified object, the tester automatically begins to discharge electricity and then finishes discharging-the LED lamp comes on and then goes out.

    • When the object under test is capacitive and electrified, the tester lets you know by turning on the LED lamp. When left connected to the object, the tester automatically discharges electricity, thus preventing possible electric shock or spike noise at power-on.

  • Battery check (BAT mark on the scale plate)

 

Specifications - Model MY10-04

Rating500V/1000MΩ
Effective Measuring Range0.5-1000MΩ
Central Scale Value20MΩ
AC Voltage Measurement0 to 500 V
Lower Limit1MΩ
Rated Current0.5-0.6 mA
Approx. Overall Scale Length107 mm
Battery LifeApprox. 10 hours when continuously operated on manganese - oxide batteries with the pointer pointing to the central scale value.
BatteriesFour AA (R6P) batteries
Approx. Width125 mm
Approx. Height103 mm
Approx. Depth53 mm
Approx. Weight500 g
ComplianceEN61010-1:1993; EN61010-2-31:1995 (Overvoltage Category III, Pollution Degree 2 installations for indoor use)
Standard AccessoriesBatteries (Qty - 4)
Earth Probe (98002) (Qty - 1)
Line Probe (98001) (Qty - 1)
Protection Cover (93013) (Qty - 1)
Shoulder Strap (99005) (Qty - 1)
User's Manual (Qty - 1)


Standard Test Conditions - Model MY10-04

Ambient Temperature/Humidity Ranges23 ±5 /45-75% RH
Position of UseHorizontal (5° max. of angle of inclination)
Battery VoltageWithin effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned ConditionsResistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.


Additional Functions - Model MY10-04

  • Automatic discharge function

    • If the object under test remains electrified after the MEAS switch is turned off, the tester lets you know by turning on the LED lamp. If you leave the tester connected to the electrified object, the tester automatically begins to discharge electricity and then finishes discharging-the LED lamp comes on and then goes out.

    • When the object under test is capacitive and electrified, the tester lets you know by turning on the LED lamp. When left connected to the object, the tester automatically discharges electricity, thus preventing possible electric shock or spike noise at power-on.

  • Battery check (BAT mark on the scale plate)

 

Specifications - Model MY10-05

Rating1000V/2000MΩ
Effective Measuring Range1-2000MΩ
Central Scale Value50MΩ
AC Voltage Measurement0 to 500 V
Lower Limit2MΩ
Rated Current0.5-0.6 mA
Approx. Overall Scale Length107 mm
Battery LifeApprox. 10 hours when continuously operated on manganese - oxide batteries with the pointer pointing to the central scale value.
BatteriesFour AA (R6P) batteries
Approx. Width125 mm
Approx. Height103 mm
Approx. Depth53 mm
Approx. Weight500 g
ComplianceEN61010-1:1993; EN61010-2-31:1995 (Overvoltage Category III, Pollution Degree 2 installations for indoor use)
Standard AccessoriesBatteries (Qty - 4)
Earth Probe (98002) (Qty - 1)
Line Probe (98001) (Qty - 1)
Protection Cover (93013) (Qty - 1)
Shoulder Strap (99005) (Qty - 1)
User's Manual (Qty - 1)


Standard Test Conditions - Model MY10-05

Ambient Temperature/Humidity Ranges23 ±5 /45-75% RH
Position of UseHorizontal (5° max. of angle of inclination)
Battery VoltageWithin effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned ConditionsResistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.


Additional Functions - Model MY10-05

  • Automatic discharge function

    • If the object under test remains electrified after the MEAS switch is turned off, the tester lets you know by turning on the LED lamp. If you leave the tester connected to the electrified object, the tester automatically begins to discharge electricity and then finishes discharging-the LED lamp comes on and then goes out.

    • When the object under test is capacitive and electrified, the tester lets you know by turning on the LED lamp. When left connected to the object, the tester automatically discharges electricity, thus preventing possible electric shock or spike noise at power-on.

  • Battery check (BAT mark on the scale plate)


ModelDescription
MY10-03Rating 500V/100MΩ; Effective Measuring Range 0.05-100MΩ; Central Scale Value 2MΩ; AC Voltage Measurement 0 to 500 V; Lower Limit 0.5MΩ; Rated Current 1-1.2 mA
MY10-01Rating 125V/20MΩ; Effective Measuring Rate 0.01-20MΩ; Central Scale Value 0.5MΩ; AC Voltage Measurement 0 to 250 V; Lower Limit 0.125MΩ; Rated Current 1-1.2 mA
MY10-05Rating 1000V/2000MΩ; Effective Measuring Range 1-2000MΩ; Central Scale Value 50MΩ ; AC Voltage Measurement 0 to 500 V; Lower Limit 2MΩ; Rated Current 0.5-0.6 mA
MY10-02Rating 250V/50MΩ; Effective Measuring Range 0.01-50MΩ; Central Scale Value 1MΩ; AC Voltage Measurement 0 to 300 V; Lower Limit 0.25MΩ; Rated Current 1-1.2 mA
MY 10-04Rating 500V/1000MΩ; Effective Measuring Rate 0.5-1000MΩ; Central Scale Value 20MΩ; AC Voltage Measurement 0 to 500 V; Lower Limit 1MΩ; Rated Current 0.5-0.6 mA