Yokogawa PH450G-A-A/PM/ANSI/SCT
2016-05-18 20:56:09
Description:
The new EXAxt 450 series builds on the superior functionality of the industry leading Yokogawa EXA series by enhancing the EXA's proven operation and application flexibility. The Model 450 series feature a uniquely simple touch screen menu structure that offers a choice of multiple languages. The Model PH450 provides the best pH measurement accuracy in the industry resulting from advanced temperature compensation functionality, preloaded calibration standards, stability checks and online sensor and analyzer diagnostics to provide verifiable results. In addition to dynamic sensor checking, the Model 450 offers a wash cycle function to assure trouble free and accurate analysis with a minimum of maintenance. The EXAxt 450 also offers full application functionality with PID control on either mA output(s) or on contact output(s). The PH450 combines pH with Temperature and ORP (Redox) measurement that can be utilized though different output functions: two mA outputs, four independent SPDT contact outputs and a digital HART signal is superimposed on mA1. This information can be used to generate additional current and contact outputs in the HIM monitor and in maintenance optimization programs like PRM or AMS. The EXAxt 450 series provides a truly unique Human Machine Interface. The high resolution graphical display and touch screen operation provides all information clearly visible and easily accessible to the operator. Simply select the language of choice and on screen instructions assure that the best configuration for the application is obtained.……
Unique touch screen operation with menu structure in 5 languages
Dual High Impedance Capability, allowing for Differential pH/ORP measurements
Enhanced diagnostics, process trending graphics andon-screen logbooks for data storage
Two mA-outputs and four SPDT relay contacts with display indicators
Hart® Communications
FM Class 1, Div.2, Group ABCD, T6 for Ta-20 to 55°C
IP66/NEMA4X 1/2 DIN enclosure for Field Mounting and Panel Mounting
Three sets of preloaded pH buffer standards (NIST, US and DIN)
New Products
FXT1-P37 Right Angle Milling Head
FXT1-P37 Right Angle Milling Head - HKXYTECH
FXT1-P24 Right Angle Milling Head
FXT1-P24 Right Angle Milling Head - HKXYTECH
FXT1-P18 Right Angle Milling Head
FXT1-P18 Right Angle Milling Head - HKXYTECH
FXT1-AC Fully Automatic Right Angle Milling Heads
FXT1-AC Fully Automatic Right Angle Milling Heads - HKXYTECH
Assortments
▶ Pressure Transmitter EJA
▶ Pressure Transmitters EJA-E
▶ Pressue Transmitter EJX
▶ Safety Instrumented System (SIS)
▶ Valve Positioners & Converters
▶ Field Mount Indicators
▶ Temperature Transmitters
▶ Magnetic Flowmeters
▶ Vortex Flowmeter
▶ Ultrasonic Flowmeters
▶ Coriolis Mass Flowmeters - ROTAMASS 3-Series
▶ Variable Area Flowmeters – Rotameters
▶ Device Smart Communicators
▶ PORTABLE AND HANDHELD INSTRUMENTS
▶ Distributed Control System (DCS)
▶ Process Analyzers
▶ Paperless Recorders
▶ Strip Chart Recorders
▶ Data Acquisition Equipment
▶ UT Series Temperature Controllers
▶ UP Series Program Controllers
▶ UM Series Digital Indicators with Alarms
▶ UT100 Series Temperature Controllers
▶ UD Series Manual Setters
▶ Limit Controllers
▶ YS Series Single-loop Controllers
Description
Yokogawa PH450G-A-A/PM/ANSI/SCT
Unique touch screen operation with menu structure in 5 languages
Dual High Impedance Capability, allowing for Differential pH/ORP measurements
Enhanced diagnostics, process trending graphics andon-screen logbooks for data storage
Two mA-outputs and four SPDT relay contacts with display indicators
Hart® Communications
FM Class 1, Div.2, Group ABCD, T6 for Ta-20 to 55°C
IP66/NEMA4X 1/2 DIN enclosure for Field Mounting and Panel Mounting
Three sets of preloaded pH buffer standards (NIST, US and DIN)
Measuring principle | Electrochemical |
---|---|
Input ranges | pH: -2 to 16 pH ORP: -1500 to 1500 mV rH: 0 to 100 rH Temperature: -30 to 140 deg C (Pt1000) |
Transmission signals | General: Two isolated outputs of 4 to 20 mA DC with common negative. Maximum load 600 Ω. Bi-directional HART® digital communication, superimposed on mA1 (4 to 20 mA) signal. Output function: Linear or Non-linear (21-step table) output for pH, temperature, ORP or rH. Control function: PID control. Burn out function: Burn up (21.0 mA) or burn down (3.6 mA) to signal failure accorded with NAMUR NE43. Hold: The mA-outputs are frozen to the last/fixed value during calibration/commissioning. |
Contact outputs | General: Four SPDT relay contacts with display indicators. Switch capacity: Maximum values 100 VA, 250 V AC, 5 A Maximum values 50 W, 250 V DC, 5 A Status: High/Low process alarms, selected from pH, ORP, rH and temperature. Configurable delay time and hysteresis. Failure annunciation. Control function: On/Off, PID duty cycle or pulsed frequency control. Wash: Contact can be used to start manual- or interval time wash cycles. Hold: Contact can be used to signal the Hold situation. Fail: Contact S4 is programmed as fail-safe contact. |
Contact input | Remote wash cycle start. |
Temperature compensation Function | Automatic or manual. Compensation to Nernst equation. Process compensation by configurable temperature coefficient, NEN6411 for water or strong acids/bases or programmable matrix. |
Calibration | Semi-automatic 1 or 2 point calibration using pre-configured NIST, US, DIN buffer tables 4, 7 & 9, or with user defined buffer tables, with automatic stability check. Manual adjustment to grab sample. |
Display | Graphical Quarter VGA (320 x 240 pixels) LCD with LED backlight and touch screen. |
Housing | Cast Aluminum housing with chemically resistant coating; Polycarbonate cover with Polycarbonate flexible window, Protection IP66/NEMA 4X/CSA Type 3S |
Power supply | PH450G-A: Ratings; 100 to 240 V AC, Acceptable range; 90 to 264 V AC Ratings; 50/60 Hz, Acceptable range; 50 Hz ±5%, 60 Hz ±5 % Power Consumption; 15 VA PH450G-D: Ratings; 12 to 24 V DC, Acceptable range; 10.8 to 26.4 V DC Power Consumption; 10 W |
Environment and operational conditions | Ambient temperature: -20 to 55℃ (-5 to 130℉) Storage temperature: -30 to 70℃ (-20 to 160℉) Humidity: 10 to 90 % RH at 40℃ (100℉) (non-condensing) |