E+H Endress+Hauser pressure transmitter FMU40
2016-05-16 01:36:40
Description:
Ultrasonic measurement Time-of-Flight Prosonic FMU40……
New Products
FXT1-P37 Right Angle Milling Head
FXT1-P37 Right Angle Milling Head - HKXYTECH
FXT1-P24 Right Angle Milling Head
FXT1-P24 Right Angle Milling Head - HKXYTECH
FXT1-P18 Right Angle Milling Head
FXT1-P18 Right Angle Milling Head - HKXYTECH
FXT1-AC Fully Automatic Right Angle Milling Heads
FXT1-AC Fully Automatic Right Angle Milling Heads - HKXYTECH
Assortments
Description
The Prosonic FMU40 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The two-wire or four-wire compact transmitter can be used in applications with storage tanks, agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate.
Transmitter in housing for field or top-hat rail mountingfor the
ultrasonic sensors FDU90/91/91F/92/93/95/96
Application for level measurement
• Continuous, non-contact level measurement of fluids,
pastes, sludge and powdery to coarse bulk materials
with 1 or 2 ultrasonic sensors
• Measuring range up to 70 m (230 ft)
(depending on sensor and material measured)
• Level limit detection (up to 6 relays)
• Pump control (alternating); rake control
• Option: additional pump control functions (pump
function test, ...)
• Calculations: average, difference, sum
Application for flow measurement
• Flow measurement in open channels and measuring
weirs with 1 or 2 ultrasonic sensors
• Simultaneous measurement of level and flow in a
stormwater overflow basin with only 1 sensor
• Flow measurement with back water detection (2
sensors) or sludge detection
• Up to 3 totalizers and 3 (resettable) counters;
optionally resettable via digital inputs
• Counting or time pulse output for control of external
units
Your benefits
• Simple, menu-guided operation with 6-line plain text
display; 15 languages selectable
• Envelope curves on the display for quick and simple
diagnosis
• Easy operation, diagnosis and measuring point
documentation with the supplied Endress+Hauser
operating program "FieldCare".
• Option: four digital inputs (e.g. for pump feedback)
and one external temperature input
• Time-of-flight correction via integrated or external
temperature sensors
• Linearization (up to 32 points, freely configurable)
• Linearization tables for the most common flumes and
weirs pre-programmed and selectable
• Online calculation of the flume-/weir-flows via
integrated flow curves
• Pre-programmed pump control routines
• System integration via HART or PROFIBUS DP
• Automatic detection of the sensors FDU9x
• The sensors of the series FDU8x can
FMU90-R11CA111AA1A
010 Approval: R Non-hazardous area
020 Application: 1 Level + pump control, alternating
030 Housing, Material: 1 Field mounting PC, IP66 NEMA4x
040 Operation: C Illuminated display + keypad
050 Power Supply: A 90-253VAC
060 Level Input: 1 1x sensor FDU9x/8x
070 Switch Output: 1 1x relay, SPDT
080 Output: 1 1x 0/4-20mA HART
090 Additional Input: A W/o
100 Datalog Function: A Basic version
110 Language: 1 DE, EN, NL, FR, ES, IT, PT
120 Additional Option: A Basic version
RH33-AA1A+AAB1D2F1R1
RH33-AA1A+AAB1D2F1R1
FTM51-AAF2M7A32AA
FTM51-AAF2M7A32AA
FTL325P-F3E3*
93PA1-FB1B00ACAABCZ1
50P40-AR1A4RC2BAAA
FMU230E-AA32 FMU231E-AA32 FMU40-ARB2A2
FMU41-ARB2A2 FMU42-APB2A22A FMU90-R11CA111AA3A
FDU91-RG1AA CPM253-MR0005 FMR250-A4E1GGJAA2K
CPS11D-7BA21 COM253-DX0005 COM223-DX0005
COS41-2F FTW325-A2B1A FTL51-AGR2DB4G5A
FTM20-AN43A FMX167-A1AME1B1 FMR230-A6VC6JBA2A
FTL325P-M1E1 FTL51-AGR2DB4G5A FTL50-AGQ2AA4G5A
FTM50-AGJ2A4A32AA FTL50-AGM2AA4G4A FMR245-A4CMKAA2A
FTM50-AGG2A4A32AA FTL50-DGQ2AA4G5A FMX167-A3ABE1B7
FTL260-0020 FMP40-ABB2GRJB21AA FTL51-AGR2DB4G5A
FTL20-0120 FTL50-KAE2AA4G5A FTL50H-ATE2AC2G6A
FTL20H-OMNJ2F FMI51-A9AGEJB3A1A FTM50-AGG2A1A32AA
FTL20H-0GDJ2B FTW325-C2A1A FMR230-14VAVJAA4A
FTL325P-F1A1 FMR250-A5E1XCJAA2K FMR240-A3V1CMJAA4A
FTL330H-RGA20 FMR540-A51APJAC4AA FMR231-AABMJAB4CA
FTL20-3225 FTL50-AGN2AA1G5A FMR250-A6E2XEJAB3K
FTL260-1020 FTL51-ABA2DB4G5A FTL50-AGR2AA1G5A
FTL260-1020 FMR240-J4E2ALJAC4A FMR240-J5E2CQJAC2A
FTL325P-F1E1 FMR230-44ECWJAC2A FMR230-45VCXJAC2A
FTE30-BA11 FTL50-AGN2AA4G4A FMR231-AAGGJAA2AA
FTE30-DB14 FTL50H-ATC2AC4G6A FMR231-6HCQKAB2CA
FTE30-JAB1 FTL50-DGN2AA2G4A FMR245-A4CWKAA2F
FTC625-C1A11 FTL51-GB82DB8G5A FMR244-A2VGGSAA2A
FTC325-A2A31 FTL51-AGR2DB4F5A FMR230-A6VC6JBA2A
FTC325-A2A31 FTL20H-0MQJ2B MR35-A1BADBAA1AAA
FTR325A1E1 FTL50-AGR2AA4F5A FMR240-A5E1CWJAA2
FTM260-N4D FTL51-AGN2DB2G5A FMR240-A5E1CQJAA2A
FDU92-RG1A FTL51-AGR2DB4G5A FTM50-AGJ2A4A32AA
FTM260-G2B FTL51-ATC2DB2G5A FTL50H-AMA2AC2G4A
FTL375P-H1E1 FMR245-A4CQKAA2A FTM50-AGJ2A4A37AA
FTL260-0010 FTL51-AGQ2DB4G7A FTL51-AGR2DB4G5A
FTL260-0020 FTC51-AG1AA51C4 PMP75-5AA1P21D4GAAA
FTC260-AB4D1 FTL50-YJE2AA4G7A FTL51-ABGKBKE4AA
FTC260-AA4D1 FTL51-IBG2BB4G7A FMU90-R11CA212AA1A
FTM260-010 FTM30-B1DA1 FTM50-AGG2A2A32AA
FTM260-G1B FMU232E-AA42 PMP46-GE13P1R1PBL
FTM260-G2B FTM260-G4D DB50-AC21BA33GG20
FTM30-A4AA1 FTM30-A4BA1 DB50-AC32BD12KG30
FTM30-A4CA1 FTM30-A4DA1 DB50L-AC00BA14EG30
FTM30-A4FA1 FTM30-A4GA1 DB50L-GC44BB13EG30
FTM30-A4HA1 FTM30-A42A1 DB50L-AC44BB13EG30
FTM30-A43A1 FTM30-A44A1 942261-0000 /FEC12
FTL51-AGR2DB4G5A L=118MM FTL51-AGR2BB4F5A L=680MM
FTL51-KGR2BB4G5A L=150MM FTL51-KAE2BB4G7A L=300MM
FTL51H-ABA2BC4G5A L=400MM FTL51-AGR2BB4G5A L=250MM
FTL51-AGR2BB1G5A L=500MM FTL51-DGQ2BB2G4A L=500MM
FTL51-AGR2BB2G5A L=148MM FTL51-AGQ2BB4F4A L=1000MM
FTL51-AGR2BB2G5A L=142MM FTL51-AGR2BB1G5A L=700MM
FTL51-FGR2BB4G5A L=1100MM FTL51-IAC2BB4E7A L=300MM
FTL51-IAC2BB4E7A L=3000MM FTI56-AAC1RV142C1A L=1100MM
FTI56-AAC1RV142C1A L=700MM FTI55-BAC2RVJ43A1A L=800MM
FTM51-XAF2L7A72AA L=500MM FTM51-XAF2L7A72AA L=1000MM