
Yokogawa Temperature Transmitter YTA70
2015-06-17 11:28:47
Description:
The YTA70 is a head mount type of temperature transmitter that accepts thermocouple, RTD, ohms or DC milivolts input and converts it to a 4 to 20 mA DC signal for transmission. The YTA70 conforms to the standard DIN form B head mounting. The YTA70 supports HART® communication protocol. HART protocol revision is selectable from HART 5 or HART 7, and HART 7 features long tag number up to 32 characters, enhanced burst mode and event notification, and command aggregation function.……
New Products
Orbinox VG SERIES 61 Slurry knife gate valve
Orbinox SERIES 61 (VG) model knife gate valve is a wafer type valve equipped with two metal reinforced rubber sleeves,designed for applications with abrasive slurries.
Crosby J-Series Direct Spring Pressure Relief Valves
J-Series valves provide high quality and dependable overpressure protection for air, gas, steam, vapor, liquid and two-phase applications in one simple design. Now available with two new to the world technologies, Balanced Diaphragm and Bellows Leak Detection.
Vanessa Series 30,000 Cryogenic Triple Offset Valve
The Vanessa Series 30,000 Cryogenic Triple Offset Valve is a virtually maintenance-free valve with tightness, operability and torque demand unaffected by cryogenic conditions and severe temperature fluctuations.
Sempell Model SOT High pressure steam safety valve
The Sempell Model SOT is a high-pressure steam safety valve designed for boiler protection and steam system safety.
Assortments
▶ Pressure Transmitter EJA
▶ Pressure Transmitters EJA-E
▶ Pressue Transmitter EJX
▶ Safety Instrumented System (SIS)
▶ Valve Positioners & Converters
▶ Field Mount Indicators
▶ Temperature Transmitters
▶ Magnetic Flowmeters
▶ Vortex Flowmeter
▶ Ultrasonic Flowmeters
▶ Coriolis Mass Flowmeters - ROTAMASS 3-Series
▶ Variable Area Flowmeters – Rotameters
▶ Device Smart Communicators
▶ PORTABLE AND HANDHELD INSTRUMENTS
▶ Distributed Control System (DCS)
▶ Process Analyzers
▶ Paperless Recorders
▶ Strip Chart Recorders
▶ Data Acquisition Equipment
▶ UT Series Temperature Controllers
▶ UP Series Program Controllers
▶ UM Series Digital Indicators with Alarms
▶ UT100 Series Temperature Controllers
▶ UD Series Manual Setters
▶ Limit Controllers
▶ YS Series Single-loop Controllers
Description
Quick Details
Place of Origin: | Denmark | Brand Name: | YOKOGAWA | Model Number: | YTA70 |
Usage: | Outdoor | Theory: | Temperature Transmitter | High performance: | Microprocesser-based sensing,long-term accuracy and high reliability |
Response Time: | 1 to 60 seconds programmable | Weight: | 50g | Terminals: | M3 screws |
Mounting: | DIN form B head mounting | Output: | Two wire 4 to 20 mA DC | Digital communication: | HART communication protocol. |
Packaging & Delivery
Packaging Details: | Carton packaging; Wooden cases |
Delivery Detail: | 8 weeks |
Yokogawa Temperature Transmitter YTA70
OVERVIEW
The YTA70 is a head mount type of temperature transmitter that accepts thermocouple, RTD , ohms or DC milivolts input and converts it to a 4 to 20 mA DC signal for transmission. The YTA70 conforms to the standard DIN formB head mounting. The YTA70 supports HART ®communication protocol.
MODEL AND SUFFIX CODES
Model | Suffix code | Descriptions | |
YTA70 | • • • • • • • • • • | Temperature Transmitter (Head Mount Type) | |
Output Signal | - E • • • • • • | 4 to 20mA DC with digital communication (HART protocol) | |
Optional Specifications | / KS2 | CENELEC ATEX (KEMA) intrinsically safe approval Applicable standard: EN 60079-0: 2006, EN 60079-11: 2007, EN 60079-26: 2007, EN 61241-0: 2006, EN 61241-11: 2006 Certificate: KEMA 10 ATEX0027 II1G Ex ia IIC T4 or T6, II1D Ex iaD Amb. temp. for gas-proof T4: -40 to 850C (-40 to 1850F), T6: -40 to 600C (-40 to 1400F) Surface temp. for dust-proof: T4: T1050C amb. temp. -40 to 850C (-40 to 1850F) T6: T850C amb. temp. -40 to 600C (-40 to 1400F) Supply/output circuit: Ui=30V, Ii=120mA, Pi=0.84W, Ci=1nF, Li=10 μH Sensor circuit: Uo=9.6V, Io=28mA, Po=67mW, Co=3.5μF, Lo=35mH | |
/ DS2 | FM intrinsically safe/Nonincendive and CENELEC ATEX (KEMA) intrinsically safe approval combination (For CENELEC ATEX Intrinsically safe approval, see /KS2) [FM Intrinsically safe/Nonincendive approval] Applicable standard: FM 3600, FM 3610, FM 3611, FM 3810 Intrinsically safe for Class I, Division 1, Groups A, B, C and D Supply: Vmax=28V, Imax=120mA, Pmax=0.84W, Ci1nF, Li10μH Nonincendive for Class I, Division 2, Groups A, B, C, D Hazardous (Classified) indoor/outdoor (TYPE 4) Locations Supply: Vmax=35V, Imax=150mA, Ci=0μF, Li=10μH Amb. temp.: T6 Ta=550C,T4 Ta=800C | ||
/ SS2 | IECEx intrinsically safe, FM intrinsically safe/Nonincendive, and CENELEC ATEX (KEMA) intrinsically safe approval combination (For FM and CENELEC ATEX intrinsically safe approval, see /KS2 and /DS2.) [IECEx intrinsically safe approval] Applicable standard: IEC 60079-0:2007-10, IEC 60079-11:2006, IEC 60079-26:2006, IEC 61241-11:2005 Certificate: IECEx KEM 10.0086 Ex ia IIC T4...T6 Ga, Ex ia IIIC T1350C...T800C Da Amb. temp.: -40 to 850C (-40 to 1850F) for T4, -40 to 450C (-40 to 1130F) for T6 Supply/output circuit: Ui=30V, Ii=120mA, Pi=0.84W, Ci=1nF, Li=10 μH Sensor circuit: Uo=9.6V, Io=28mA, Po=67mW, Co=3.5μF, Lo=35mH |