yokogawa pressure transmitter calibration YTA50/YTA70
2015-06-17 10:49:01
Description:
The YTA50 is a head mount type of temperature transmitter that accepts thermocouple, RTD, ohms or DC milivolts input and converts it to a 4 to 20 mA DC signal for transmission. The YTA50 conforms to the standard DIN formB head mounting.……
New Products
Orbinox VG SERIES 61 Slurry knife gate valve
Orbinox SERIES 61 (VG) model knife gate valve is a wafer type valve equipped with two metal reinforced rubber sleeves,designed for applications with abrasive slurries.
Crosby J-Series Direct Spring Pressure Relief Valves
J-Series valves provide high quality and dependable overpressure protection for air, gas, steam, vapor, liquid and two-phase applications in one simple design. Now available with two new to the world technologies, Balanced Diaphragm and Bellows Leak Detection.
Vanessa Series 30,000 Cryogenic Triple Offset Valve
The Vanessa Series 30,000 Cryogenic Triple Offset Valve is a virtually maintenance-free valve with tightness, operability and torque demand unaffected by cryogenic conditions and severe temperature fluctuations.
Sempell Model SOT High pressure steam safety valve
The Sempell Model SOT is a high-pressure steam safety valve designed for boiler protection and steam system safety.
Assortments
▶ Pressure Transmitter EJA
▶ Pressure Transmitters EJA-E
▶ Pressue Transmitter EJX
▶ Safety Instrumented System (SIS)
▶ Valve Positioners & Converters
▶ Field Mount Indicators
▶ Temperature Transmitters
▶ Magnetic Flowmeters
▶ Vortex Flowmeter
▶ Ultrasonic Flowmeters
▶ Coriolis Mass Flowmeters - ROTAMASS 3-Series
▶ Variable Area Flowmeters – Rotameters
▶ Device Smart Communicators
▶ PORTABLE AND HANDHELD INSTRUMENTS
▶ Distributed Control System (DCS)
▶ Process Analyzers
▶ Paperless Recorders
▶ Strip Chart Recorders
▶ Data Acquisition Equipment
▶ UT Series Temperature Controllers
▶ UP Series Program Controllers
▶ UM Series Digital Indicators with Alarms
▶ UT100 Series Temperature Controllers
▶ UD Series Manual Setters
▶ Limit Controllers
▶ YS Series Single-loop Controllers
Description
Quick Details
Place of Origin: | Japan | Brand Name: | Yokogawa | Model Number: | YTA50 |
Usage: | Industrial | Theory: | Temperature Transmitter | Accuracy (typical): | YTA50: ±0.1% of span or ±0.2deg C(0.36deg F) |
Cold junction Compensation accuracy: | (For T/C only) ±1 deg C (1.8 deg F) | Ambient temperature effect: | (±0.1% or ±0.1deg C) / 10 deg C | Input signal: | Single input is selectable |
Output: | Two wire 4 to 20 mA DC | Supply voltage: | 7 to 35 V DC | Ambient temperature: | Option code may affect limits -40 to 85 deg C (-40 to 185 deg F) |
Mounting: | DIN form B head mounting | Weight: | 50g (0.11lb) | Certificates: | ATEX, FM, or IECEx |
Packaging & Delivery
Packaging Details: | in carton or according to custom's service |
Delivery Detail: | 2 weeks |
Specifications
Yokogawa Temperature Transmitters YTA50
1.Outstanding performance
2.HART communication protocol
3.Variety sensor inputs
Yokogawa Temperature Transmitters YTA110 YTA310 YTA320 YTA50 and YTA70
The YTA50 and YTA70 are head mount type of temperature transmitters that conform to the standard DIN formB head mounting.
The YTA50 is a head mount temperature transmitter with a single input. The single input accepts thermocouples, RTD, Ohms or a DC millivolt source. All inputs are linearized and converted in to an industrial standard 4 to 20 mA DC output for transmission to your system. YTA50 is the optimum choice for all your monitoring applications.
YTA50 features include:
4 to 20 mA DC analog output
16 Input Types
DIN Form B compliant
Features: Temperature Transmitters YTA50/YTA70
Outstanding performance
Microprocessor-based sensing technology ensures high accuracy and stability.
Variety of sensor inputs
The type of sensor input is user-selectable: thermocouples, RTDs, ohms, or DC milivolt.
Digital communication
The YTA70 supports HART communication protocol.
Specifications: Temperature Transmitters YTA50/YTA70
Accuracy (typical) | YTA50: ±0.1% of span or ±0.2deg C(0.36deg F) YTA70: ±0.1% of span or ±0.1deg C(0.18deg F) |
Cold junction Compensation accuracy | (For T/C only) ±1 deg C (1.8 deg F) |
Power supply effect | ±0.005% of FS per volt |
Ambient temperature effect | YTA50: (±0.1% or ±0.1deg C) / 10 deg C YTA70: (±0.05% or ±0.05deg C) / 10 deg C |
Input signal | Single input Input type is selectable: thermocouples, 2-, 3-, and 4-wire RTDs, ohm and DC milivolt |
Output | Two wire 4 to 20 mA DC |
Supply voltage | 7 to 35 V DC (7 to 28 V DC for Intrinsically safe type) |
Ambient temperature | Option code may affect limits -40 to 85 deg C (-40 to 185 deg F) |
Mounting | DIN form B head mounting |
Weight | 50g (0.11lb) |
Certificates | CENELEC or FM |