Yokogawa Relay Output Module ADR541-P50
2016-03-24 19:34:07
Description:
Yokogawa Relay Output Module ADR541-P50,The Relay Output Module outputs the 16-channel relay contact signals. It can be used in dual redundant configuration.……
Yokogawa Relay Output Module ADR541-P50,Yokogawa original packing, by carton,Place of Origin: Singapore
New Products
Orbinox VG SERIES 61 Slurry knife gate valve
Orbinox SERIES 61 (VG) model knife gate valve is a wafer type valve equipped with two metal reinforced rubber sleeves,designed for applications with abrasive slurries.
Crosby J-Series Direct Spring Pressure Relief Valves
J-Series valves provide high quality and dependable overpressure protection for air, gas, steam, vapor, liquid and two-phase applications in one simple design. Now available with two new to the world technologies, Balanced Diaphragm and Bellows Leak Detection.
Vanessa Series 30,000 Cryogenic Triple Offset Valve
The Vanessa Series 30,000 Cryogenic Triple Offset Valve is a virtually maintenance-free valve with tightness, operability and torque demand unaffected by cryogenic conditions and severe temperature fluctuations.
Sempell Model SOT High pressure steam safety valve
The Sempell Model SOT is a high-pressure steam safety valve designed for boiler protection and steam system safety.
Assortments
▶ Pressure Transmitter EJA
▶ Pressure Transmitters EJA-E
▶ Pressue Transmitter EJX
▶ Safety Instrumented System (SIS)
▶ Valve Positioners & Converters
▶ Field Mount Indicators
▶ Temperature Transmitters
▶ Magnetic Flowmeters
▶ Vortex Flowmeter
▶ Ultrasonic Flowmeters
▶ Coriolis Mass Flowmeters - ROTAMASS 3-Series
▶ Variable Area Flowmeters – Rotameters
▶ Device Smart Communicators
▶ PORTABLE AND HANDHELD INSTRUMENTS
▶ Distributed Control System (DCS)
▶ Process Analyzers
▶ Paperless Recorders
▶ Strip Chart Recorders
▶ Data Acquisition Equipment
▶ UT Series Temperature Controllers
▶ UP Series Program Controllers
▶ UM Series Digital Indicators with Alarms
▶ UT100 Series Temperature Controllers
▶ UD Series Manual Setters
▶ Limit Controllers
▶ YS Series Single-loop Controllers
Description
Yokogawa Relay Output Module ADR541-P50
Relay Output Module ADR541-P50
The Relay Output Module outputs the 16-channel relay contact signals.
It can be used in dual redundant configuration.
Item Specifications
Model ADR541
Number of output channels 16
Rated applied voltage 24 to 110 V DC, 100 to 240 V AC, 50/60 Hz
Maximum load current (*1)
Resistive load:
24 V DC: 2.0 A/channel, 110 V DC: 0.4 A/channel
100 V AC: 2.0 A/channel, 220 V AC: 2.0 A/channel
Inductive load:
24 V DC: 0.6 A/channel, 110 V DC: 0.1 A/channel
100 V AC: 1.0 A/channel, 220 V AC: 1.0 A/channel
Withstanding voltage Between output signal and system: 2 kV AC, For 1 minute
Between commons: 1.35 kV AC, For 1 minute, common minus (–) side every 8-channel
Functions
Status output ON/OFF status output function
Pulse width output One-shot pulse width output function
Time-proportioning output Time-proportioning ON/OFF
Output response time 12 ms or less (for status output) 20 ms or less (for mixed status and pulse outputs)
Pulse width 40 ms to 7200 s
Pulse width resolution 8 ms, but ON/OFF delay added for maximum 10 ms
Maximum current consumption 780 mA (5 V DC)
Weight 0.3 kg
External connection Pressure clamp terminal, Dedicated cable (AKB334)
Relay switching life 100000 operations (*2)
Yokogawa Relay Output Module ADR541-P50
Description
Model ADR541 Relay Output Module (16-channel, 24 to 110 V DC/100 to 240 V AC, Isolated)
Suffix
Codes
-P With pulse width output function/time-proportional output function
5 Without status display; with no explosion protection
E Without status display; with explosion protection
0 Basic type
3 With ISA Standard G3 option and temperature (-20 to 70 °C) option
Option
Code /C4S70 With Pressure Clamp Terminal Block for Digital Input [Model : ATC4S-70]
Yokogawa Relay Output Module ADR541-P50
ADR541 Relay Output Module (16-channel, 24 to 110 V DC/100 to 240 V AC, Isolated)
ADR541-P50/C4S70, ADR541-P53/C4S70, ADR541-PE0/C4S70, ADR541-PE3/C4S70
ADV557 Digital Output Module (32-channel, 24 V DC, Pressure Clamp Terminal support only, Isolated)
ADV557-S50
ADV557-S51
ADV557-E50
ADV557-E51
ADV561 Digital Output Module (64-channel, 24 V DC, Isolated)
ADV561-P50
ADV561-P51
ADV561-E50
ADV561-E51
ADV859 Digital I/O Module for Compatible ST2 (16-channel input/16-channel output, Isolated channels)
ADV859-P00
ADV859-P01
ADV159 Digital Input Module for Compatible ST3 (32-channel, Isolated channels)
ADV159-P00
ADV159-P01
ADV559 Digital Output Module for Compatible ST4 (32-channel output, Isolated channels)
ADV559-P00
ADV559-P01
ADV869 Digital I/O Module for Compatible ST5 (32-channel input/32-channel output, Isolated, Common Minus Side Every 16-channel)
ADV869-P00
ADV869-P01
ADV169 Digital Input Module for Compatible ST6 (64-channel, Isolated, Common Minus Side Every 16-channel)
ADV169-P00
ADV169-P01
ADV569 Digital Output Module for Compatible ST7 (64-channel output, Isolated, Common Minus Side Every 16-channel)
ADV569-P00
ADV569-P01
Yokogawa Relay Output Module ADR541-P50