Yokogawa TC/mV Input Module AAT141 -SE3
2016-03-22 20:49:24
Description:
Yokogawa TC/mV Input Module AAT141 -SE3,Yokogawa Analog I/O modules function as signal converters; by inputting field analog signals into these modules ……
Yokogawa TC/mV Input Module AAT141 -SE3,Place of Origin: Indonesia,Yokogawa original packing, by carton
New Products
FXT1-P37 Right Angle Milling Head
FXT1-P37 Right Angle Milling Head - HKXYTECH
FXT1-P24 Right Angle Milling Head
FXT1-P24 Right Angle Milling Head - HKXYTECH
FXT1-P18 Right Angle Milling Head
FXT1-P18 Right Angle Milling Head - HKXYTECH
FXT1-AC Fully Automatic Right Angle Milling Heads
FXT1-AC Fully Automatic Right Angle Milling Heads - HKXYTECH
Assortments
▶ Pressure Transmitter EJA
▶ Pressure Transmitters EJA-E
▶ Pressue Transmitter EJX
▶ Safety Instrumented System (SIS)
▶ Valve Positioners & Converters
▶ Field Mount Indicators
▶ Temperature Transmitters
▶ Magnetic Flowmeters
▶ Vortex Flowmeter
▶ Ultrasonic Flowmeters
▶ Coriolis Mass Flowmeters - ROTAMASS 3-Series
▶ Variable Area Flowmeters – Rotameters
▶ Device Smart Communicators
▶ PORTABLE AND HANDHELD INSTRUMENTS
▶ Distributed Control System (DCS)
▶ Process Analyzers
▶ Paperless Recorders
▶ Strip Chart Recorders
▶ Data Acquisition Equipment
▶ UT Series Temperature Controllers
▶ UP Series Program Controllers
▶ UM Series Digital Indicators with Alarms
▶ UT100 Series Temperature Controllers
▶ UD Series Manual Setters
▶ Limit Controllers
▶ YS Series Single-loop Controllers
Description
Yokogawa TC/mV Input Module AAT141 -SE3
STANDARD SPECIFICATIONS of AAT141 -SE3
TC/RTD Input Modules (Isolated)
AAT141 These modules receive signals from mV, thermocouple (TC), and RTD. They can be used in dual-redundant
Items | Specifications | |
Model | AAT141 | AAR181 |
Number of input channels | 16, isolated (*7) | 12, isolated |
Input signal | TC: JIS C1602:1995, IEC584:1995 Type J, K, E, B(*1), R, S, T, N mV: -100 to 150 mV, -20 to 80 mV | RTD: JIS C1604:1997, IEC751:1995 Pt100 (3-wire type)(*6) |
Switching input signals | TC/mV can be set individually for CH1 to CH16. | CH1 to CH12 are RTD inputs. |
Allowable input voltage | ±5 V | ±5 V |
Withstanding voltage | Between input and system: 1500 V AC, for 1 minute | |
Input resistance | Power ON 2 MΩ or larger | |
Power OFF 2 MΩ or larger | ||
Accuracy | TC: ±30 μV MV: ±80 μV for span (-100 to 150 mV) ±30 μV for span (-20 to 80 mV) | RTD: ±120 mΩ |
Allowable total resistance of signal source plus wiring | 1000 Ω or less | 40 Ω or less (wiring resistance per wire) (*2) |
Effect of allowable signal source resistance (1000 Ω) | ±20 μV(*3) | |
Reference junction compensation accuracy | Within ±1 °C (*4) (*5) | |
Measurement current | RTD: 1 mA | |
Temperature drift | ±80 μV/10 °C (-100 to 150 mV input) ±30 μV/10 °C (TC/-20 to 80 mV input | ±120 mΩ/10 °C (RTD input) |
Data update period | 1 s | |
Burn-out | All channels can be set together. Setting: Not available/available (UP/DOWN) Detection time: 60 s | |
Maximum current consumption | 450 mA (5 V DC) | 450 mA (5 V DC) |
Weight | 0.2 kg |
Yokogawa TC/mV Input Module AAT141 -SE3
EXTERNAL DIMENSIONS of AAT141 -SE3
Yokogawa TC/mV Input Module AAT141 -SE3
MODEL AND SUFFIX CODES AAT141 -SE3
Description | ||
Model | AAT141 | TC/mV Input Module (16-channel, Isolated) |
-S | Standard type | |
Suffix Codes | 5 | With no explosion protection |
E | With explosion protection | |
0 | Basic type | |
3 | With ISA Standard G3 option and temperature (-20 to 70 °C) option | |
Option Codes | ||
/T4S00 | With Pressure Clamp Terminal Block for Thermocouple/mV [Model: ATT4S-00] | |
/T4S10 | With Pressure Clamp Terminal Block for Thermocouple/mV (surge absorber) [Model: ATT4S-10] | |
/T4D00 | With Dual Pressure Clamp Terminal Block for Thermocouple/mV [Model: ATT4D-00] | |
/T4D10 | With Dual Pressure Clamp Terminal Block for Thermocouple/mV (surge absorber) [Model: ATT4D-10] | |
/CCC01 | With Connector Cover for MIL Cable [Model: ACCC01 |