Yokogawa Analog Output Module AAV544-S53
2016-03-22 19:52:51
Description:
Yokogawa Analog Output Module AAV544-S53,Yokogawa Analog I/O modules function as signal converters; by inputting field analog signals into these modules ……
Yokogawa Analog Output Module AAV544-S53,Place of Origin: Indonesia,Yokogawa original packing, by carton
New Products
FXT1-P37 Right Angle Milling Head
FXT1-P37 Right Angle Milling Head - HKXYTECH
FXT1-P24 Right Angle Milling Head
FXT1-P24 Right Angle Milling Head - HKXYTECH
FXT1-P18 Right Angle Milling Head
FXT1-P18 Right Angle Milling Head - HKXYTECH
FXT1-AC Fully Automatic Right Angle Milling Heads
FXT1-AC Fully Automatic Right Angle Milling Heads - HKXYTECH
Assortments
▶ Pressure Transmitter EJA
▶ Pressure Transmitters EJA-E
▶ Pressue Transmitter EJX
▶ Safety Instrumented System (SIS)
▶ Valve Positioners & Converters
▶ Field Mount Indicators
▶ Temperature Transmitters
▶ Magnetic Flowmeters
▶ Vortex Flowmeter
▶ Ultrasonic Flowmeters
▶ Coriolis Mass Flowmeters - ROTAMASS 3-Series
▶ Variable Area Flowmeters – Rotameters
▶ Device Smart Communicators
▶ PORTABLE AND HANDHELD INSTRUMENTS
▶ Distributed Control System (DCS)
▶ Process Analyzers
▶ Paperless Recorders
▶ Strip Chart Recorders
▶ Data Acquisition Equipment
▶ UT Series Temperature Controllers
▶ UP Series Program Controllers
▶ UM Series Digital Indicators with Alarms
▶ UT100 Series Temperature Controllers
▶ UD Series Manual Setters
▶ Limit Controllers
▶ YS Series Single-loop Controllers
Description
Yokogawa Analog Output Module AAV544-S53
STANDARD SPECIFICATIONS of AAV544-S53
Current/Voltage Input Modules (Non-Isolated)
These modules provide 16 inputs of mainly 4 to 20 mA DC or 1 to 5 V DC standardized signals from 2-wire/4-wire transmitters.
They can be used in dual-redundant configuration.
Voltage Input Module (Isolated)
AAV144 is for 16 inputs of 1 to 5 V or -10 to 10 V signal. It can be used in dual-redundant configuration
Items | Specifications |
Model | AAV144 |
Number of output channels | 16, isolated |
Output signal | -10 to 10 V |
Withstanding voltage | Between output and system: 1500 V AC withstanding voltage, for 1 minute (*1) |
Allowable load resistance | 5 kΩ or larger |
Accuracy | The larger of ±12 mV or ±0.3 % FS |
Data update period | 10 ms |
Drift due to ambient temperature change | The larger of ±0.1 %/10 C or ±10 mV/10 C |
Maximum current consumption | 860 mA (5 V DC) |
Weight | 0.2 kg |
External communication | Pressure clamp terminal, MIL connector cable, dedicated cable (KS1) |
*1: When the dedicated cable is used, the withstanding voltage is 500 V AC (between the input signal and the system). When
the ML connector cable is used, the withstanding voltage depends on the electrical specifications of the cable.
Yokogawa Analog Output Module AAV544-S53
EXTERNAL DIMENSIONS of AAV544-S53
Yokogawa Analog Output Module AAV544-S53
MODEL AND SUFFIX CODES AAV544-S53
Description | ||
Model | AAV544 | Analog Output Module (-10 to +10 V, 16-channel, Isolated) |
-S | Standard type | |
Suffix Codes | 5 | With no explosion protection |
E | With explosion protection | |
0 | Basic type | |
3 | With ISA Standard G3 option and temperature (-20 to 70 °C) option | |
Option Codes | /K4A00 | With KS Cable Interface Adapter [Model: ATK4A-00] |
/A4S00 | With Pressure Clamp Terminal Block for Analog [Model: ATA4S-00] | |
/A4S10 | With Pressure Clamp Terminal Block for Analog (surge absorber) [Model: ATA4S-10] | |
/A4D00 | With Dual Pressure Clamp Terminal Block for Analog [Model: ATA4D-00] | |
/A4D10 | With Dual Pressure Clamp Terminal Block for Analog (surge absorber) [Model: ATA4D-10] | |
/CCC01 | With Connector Cover for MIL Cable [Model: ACCC01 |
Yokogawa Analog Output Module AAV544-S53