Yokogawa TC/mV Input Module AAT145-S50
2016-03-21 00:02:27
Description:
Yokogawa TC/mV Input Module AAT145-S50, okogawa Analog I/O modules function as signal converters; by inputting field analog signals into these modules ……
Yokogawa original packing, by carton, Place of Origin: Indonesia
New Products
OMRON CS1W-CN133 CS1 I/O Connecting Cable
OMRON CS1W-CN133 CS1 I/O Connecting Cable. Connects CS1 Expansion I/O Backplanes to CPU Backplanes or other CS1 Expansion I/O Backplanes.
OMRON CS1W-AD041-V1 CS1W series Analog Input Unit
OMRON CS1W-AD041-V1 CS1W series Analog Input Unit. Contact us to learn more about the OMRON CS1G/CS1H/CS1W/CS1D SYSMAC CS1 Programmable Controller.
OMRON CS1H-CPU63H CS1H CPU Unit
OMRON CS1H-CPU63H CS1H CPU Unit. Omron CS1 Series is widely used in industrial automation applications such as production line control, process monitoring, packaging, material handling, and power plant systems.
OMRON CS1G-CPU42H CS1G CPU Unit
OMRON CS1G-CPU42H CS1G CPU Unit. Ideal for control of power generators, water supply utilities, 24/7 production.
Assortments
▶ Pressure Transmitter EJA
▶ Pressure Transmitters EJA-E
▶ Pressue Transmitter EJX
▶ Safety Instrumented System (SIS)
▶ Valve Positioners & Converters
▶ Field Mount Indicators
▶ Temperature Transmitters
▶ Magnetic Flowmeters
▶ Vortex Flowmeter
▶ Ultrasonic Flowmeters
▶ Coriolis Mass Flowmeters - ROTAMASS 3-Series
▶ Variable Area Flowmeters – Rotameters
▶ Device Smart Communicators
▶ PORTABLE AND HANDHELD INSTRUMENTS
▶ Distributed Control System (DCS)
▶ Process Analyzers
▶ Paperless Recorders
▶ Strip Chart Recorders
▶ Data Acquisition Equipment
▶ UT Series Temperature Controllers
▶ UP Series Program Controllers
▶ UM Series Digital Indicators with Alarms
▶ UT100 Series Temperature Controllers
▶ UD Series Manual Setters
▶ Limit Controllers
▶ YS Series Single-loop Controllers
Description
Yokogawa TC/mV Input Module AAT145-S50
STANDARD SPECIFICATIONS of AAT145-S50
TC/RTD Input Modules (Isolated Channels)
AAT145, AAR145 These modules receive signals from mV, thermocouple (TC), RTD, and potentiometer (POT), and they are isolated between the field and the system as well as in between each channel. They can be used in dual-redundant configuration.
| Items | Specifications | |
| Model | AAT145 | AAR145 |
| Number of input channels | 16, isolated channels | 16, isolated channels |
| Input signal | TC: JIS C1602:1995 (*1), IEC584:1995 Type J, K, E, B (*2), R, S, T, N mV: -100 to 150 mV, -20 to 80 Mv | RTD: JIS C1604:1997 (*3), IEC751:1995 Pt100 (3-wire type) POT: Total resistance 100 Ω to 10 kΩ Span resistance: 50 % or larger of total resistance |
| Switching input signals | TC/mV can be set individually for CH1 to CH16 | RTD/POT can be selected individually for CH1 to CH16. |
| Allowable input voltage | ±5 V | ±5 V |
| Withstanding voltage | Between input and system: 500 V AC (for single card: 1500 V AC), For 1 minute Between input channels: 200 V AC, For 1 minute | |
| Input resistance | Power ON 1 MΩ or larger | |
| Power OFF 1 MΩ or larger | ||
| Accuracy | ±40 μV | RTD: ±150 mΩ POT: ±0.2 %/FS |
| Allowable total resistance of signal source plus wiring | 1000 Ω or less | 150 Ω or less (wiring resistance per wire) (*4) |
| Effect of allowable signal source resistance (1000 Ω) | ±20 μV | |
| Reference junction compensation accuracy | ±1 °C (*5) (6) | |
| Measurement current | RTD: 1 mA | |
| Data update period | 1 s | |
| Burn-out | All channels can be set together. Setting: not available/available (UP/DOWN) Detection time: 60 s | |
| Temperature drift | ±80 μV/10 °C | RTD: ±0.3 Ω/10 °C POT: ±0.4 %/10 °C |
| Maximum current consumption | 350 mA (5 V DC) | 350 mA (5 V DC) |
| Weight | 0.3 kg | |
| External connection | Dedicated cable (KS1) | Dedicated cable (KS8/AKB335) |
Yokogawa TC/mV Input Module AAT145-S50
EXTERNAL DIMENSIONS of AAT145-S50 
Yokogawa TC/mV Input Module AAT145-S50
MODEL AND SUFFIX CODES AAT145-S50
| Description | ||
| Model | AAT145 | TC/mV Input Module (16-channel, Isolated channels) |
| Suffix Codes | -S | Standard type |
| 5 | With no explosion protection | |
| E | With explosion protection | |
| 0 | Basic type | |
| 3 | With ISA Standard G3 option and temperature (-20 to 70 °C) option |