Pepperl+Fuchs Termination Boards
2015-11-17 15:34:27
Description:
HiCTB08-YC3-RRB-KS-CC-AM08 Termination Board System Board for Yokogawa CENTUM VP, For 8-channel AI card AAI135, For 8-channel AI/AO card AAI835, For 8 modules, Recommended modules: HiC2025 (AI), HiC2031 (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin……
New Products
Orbinox VG SERIES 61 Slurry knife gate valve
Orbinox SERIES 61 (VG) model knife gate valve is a wafer type valve equipped with two metal reinforced rubber sleeves,designed for applications with abrasive slurries.
Crosby J-Series Direct Spring Pressure Relief Valves
J-Series valves provide high quality and dependable overpressure protection for air, gas, steam, vapor, liquid and two-phase applications in one simple design. Now available with two new to the world technologies, Balanced Diaphragm and Bellows Leak Detection.
Vanessa Series 30,000 Cryogenic Triple Offset Valve
The Vanessa Series 30,000 Cryogenic Triple Offset Valve is a virtually maintenance-free valve with tightness, operability and torque demand unaffected by cryogenic conditions and severe temperature fluctuations.
Sempell Model SOT High pressure steam safety valve
The Sempell Model SOT is a high-pressure steam safety valve designed for boiler protection and steam system safety.
Assortments
Description
HiCTB08-YC3-RRB-KS-CC-AM08
Termination Board
System Board for Yokogawa CENTUM VP, For 8-channel AI card AAI135, For 8-channel AI/AO card AAI835, For 8 modules, Recommended modules: HiC2025 (AI), HiC2031 (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
HiCTB08-YRS-RRB-AK-CC-DI16
Termination Board
System Board for Yokogawa ProSafe-RS, For 16-channel DI card SDV144, For 8 modules, Recommended module: HiC2832R1 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin
HiCTB08-YRS-RRB-AK-CC-DO08
Termination Board
System Board for Yokogawa ProSafe-RS, For 8-channel DO card SDV531, For 8 modules, Recommended module: HiC2871 (DO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin
HiCTB08-YRS-RRB-KS-CC-AO08
Termination Board
System Board for Yokogawa ProSafe-RS, For 8-channel AO card SAI533, For 8 modules, Recommended module: HiC2031 (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
HiCTB16-YC3-RRB-AK-CC-DX32
Termination Board
System Board for Yokogawa CENTUM VP, For 32-channel DI card ADV151, For 16 modules, Recommended module: HiC2822 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin
HiCTB16-YC3-RRB-KS-CC-AI16
Termination Board
System Board for Yokogawa CENTUM VP, For 16-channel AI card AAI143, For 16 modules, Recommended module: HiC2025 (AI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
HiCTB16-YC3-RRB-KS-CC-AI16-Y1
Termination Board
System Board for Yokogawa CENTUM VP, For 16-channel AI card AAI141, For 16 modules, Recommended module: HiC2025 (AI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
HiCTB16-YC3-RRB-KS-CC-AI16-Y2
Termination Board
System Board for Yokogawa CENTUM VP, For 16-channel AI card AAV141, For 16 modules, Recommended module: HiC2025 (AI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
HiCTB16-YC3-RRB-KS-CC-AM16
Termination Board
System Board for Yokogawa CENTUM VP, For 16-channel AI/AO card AAI841, For 16 modules, Recommended modules: HiC2025 (AI), HiC2031 (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
HiCTB16-YC3-RRB-KS-CC-AM16-Y1
Termination Board
System Board for Yokogawa CENTUM VP, For 16-channel AI/AO card AAB841, For 16 modules, Recommended modules: HiC2025 (AI), HiC2031 (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
HiCTB16-YC3-RRB-KS-CC-AO16
Termination Board
System Board for Yokogawa CENTUM VP, For 16-channel AO card AAI543, For 16 modules, Recommended module: HiC2031 (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
HiCTB16-YRS-RRB-AK-CC-DI16
Termination Board
System Board for Yokogawa ProSafe-RS, For 16-channel DI card SDV144, For 16 modules, Recommended modules: HiC2831R1 (DI), HiC2853R1 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin
HiCTB16-YRS-RRB-AK-CC-DO16
Termination Board
System Board for Yokogawa ProSafe-RS, For 16-channel DO card SDV541, For 16 modules, Recommended modules: HiC2871 (DO), HiC2873 (DO), HiC2877 (DO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin
HiCTB16-YRS-RRB-KS-CC-AI16
Termination Board
System Board for Yokogawa ProSafe-RS, For 16-channel AI card SAI143, For 16 modules, Recommended module: HiC2025 (AI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
HiCTB16-YRS-RRB-KS-CC-AI16-Y1
Termination Board
System Board for Yokogawa ProSafe-RS, For 16-channel AI card SAV144, For 16 modules, Recommended module: HiC2025 (AI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
HiCTB32-YC3-RRB-AK-CC-DX32
Termination Board
System Board for Yokogawa CENTUM VP, For 32-channel DI card ADV151, For 32 modules, Recommended module: HiC2821 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin
HiCTB32-YC3-RRB-AK-CC-DX32-Y1
Termination Board
System Board for Yokogawa CENTUM VP, For 32-channel DO card ADV551, For 32 modules, Recommended module: HiC2871 (DO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin
HiDTB08-YC3-RRB-AK-CC-DX32
Termination Board
System Board for Yokogawa CENTUM VP, For 32-channel DI card ADV151, For 8 modules, Recommended module: HiD2824 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin
HiDTB08-YC3-RRB-KS-CC-AI16
Termination Board
System Board for Yokogawa CENTUM VP, For 16-channel AI card AAI143, For 8 modules, Recommended modules: HiD2026 (AI), HiD2030 (AI), HiD2082 (TI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
HiDTB08-YC3-RRB-KS-CC-AI16-Y1
Termination Board
System Board for Yokogawa CENTUM VP, For 16-channel AI card AAV141, For 8 modules, Recommended modules: HiD2026 (AI), HiD2030 (AI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
HiDTB08-YC3-RRB-KS-CC-AM16
Termination Board
System Board for Yokogawa CENTUM VP, For 16-channel AI/AO card AAB841, For 8 modules, Recommended modules: HiD2026 (AI), HiD2038Y (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
HiDTB08-YC3-RRB-KS-CC-AM16-Y1
Termination Board
System Board for Yokogawa CENTUM VP, For 16-channel AI/AO card AAI841, For 8 modules, Recommended modules: HiD2026 (AI), HiD2030 (AI), HiD2032 (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
HiDTB08-YC3-RRB-KS-CC-AO16
Termination Board
System Board for Yokogawa CENTUM VP, For 16-channel AO card AAI543, For 8 modules, Recommended module: HiD2038Y (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
HiDTB08-YRS-RRB-AK-CC-DO16
Termination Board
System Board for Yokogawa ProSafe-RS, For 16-channel DO card SDV541, For 8 modules, Recommended modules: HiD2872 (DO), HiD2876 (DO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin
HiDTB08-YRS-RRB-KS-CC-AI16
Termination Board
System Board for Yokogawa ProSafe-RS, For 16-channel AI card SAI143, For 8 modules, Recommended modules: HiD2026 (AI), HiD2030 (AI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
HiDTB08-YRS-RRB-KS-CC-AI16-Y1
Termination Board
System Board for Yokogawa ProSafe-RS, For 16-channel AI card SAV144, For 8 modules, Recommended modules: HiD2026 (AI), HiD2030 (AI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
HiDTB16-YC3-RRB-AK-CC-DX32
Termination Board
System Board for Yokogawa CENTUM VP, For 32-channel DO card ADV551, For 16 modules, Recommended modules: HiD2872 (DO), HiD2876 (DO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 50-pin
HiDTB16-YC3-RRB-KS-CC-AI16
Termination Board
System Board for Yokogawa CENTUM VP, For 16-channel AI card AAI143, For 16 modules, Recommended module: HiD2081 (TI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin