Honeywell Analytics Manning AirAlert 96d Toxic and Combustible Gas Detector Gas Detection Controllers
2019-03-08 16:19:53
Description:
Multi-channel gas monitoring system acts as the nerve center of a modular gas detection network, providing continuous……
New Products
Honeywell 51307038-100 Power Control Module Assy
Honeywell 51307038-100 Power Control Module Assy. Honeywell Experion LX Series 8 C300 controller provides powerful and robust control for the Experion LX platform.
Honeywell 8937-HN2 Fibre Optic converter IO Module
Honeywell 8937-HN2 Multi-Mode, Fibre Optic converter IO Module. The Fiber Option Extender modules support the extension of the I/O link beyond the Series 8 cabinet with the S8 C300, enabling remote applications of the Series 8 I/O.
Honeywell 8939-HN Multi-Mode Fiber Optic Extender (IOTA)
Honeywell 8939-HN Multi-Mode Fiber Optic Extender IOTA. The Fiber Option Extender modules support the extension of the I/O link beyond the Series 8 cabinet with the S8 C300, enabling remote applications of the Series 8 I/O.
G.M. International X1-IS-AO-02-S I.S. SIL2 HART® Isolating Driver module
G.M. International X1-IS-AO-02-S I.S. SIL2 HART® Isolating Driver module. GMI Intrinsically Safe Isolators, Analog Output
Assortments
Description
Honeywell Analytics Manning AirAlert 96d Toxic and Combustible Gas Detector Gas Detection Controllers
General Specification | |
Use | Multi-channel gas monitoring system acts as the nerve center of a modular gas detection network, providing continuous monitoring of up to 96 connected units on three distinct channels. |
Common Operation | |
Display | Graphic 122 x 82 alphanumeric dot matrix backlit |
Push Button Controls | Seven user-friendly pushbuttons easily performs operations from minor fine tuning to reconfiguration of entire network |
Electrical Power | 24 VDC, 500 mA (18-36 VDC) |
Communication Addressable | RS-485 Modbus protocol |
Power Supply | External M-600400 24 VDC, 6.5 amps, enclosure complies with Nema 4 requirements |
Environmental | |
Operating Altitude | Up to 3,000 m (9843 ft.) |
Operating Environment | Ordinary location |
Operational Humidity | 0-95% RH (non-condensing) |
Temperature | -20°C to +50°C (-4°F to +122°F) |
Common Module | |
Communication | RS-485: for communication cable, use 24 AWG twisted pair, shielded (Belden #9841 or equal), cable runs up to 2,000 ft. For power cable use 14 AWG (Belden #5100UE or equal), cable runs up to 1,000 feet.(Belden #5100UE or equal), cable runs up to 1,000 feet |
Network Capacity | Up to 96 sensors, 32 per channel Channel 1, 2, and 3 |
Visual Indicators | Power On Green LED Warn Red LED (blinks upon an event) Alarm Red LED High Alarm Red LED Fault Yellow LED Tx Amber LED (blinks when used) Rx Green LED (blinks when used) |
Outputs | |
Relays | 4 DPDT relays 5A, 30 Vdc or 250 VAC/30 VDC Field selectable: energized/de-energized Red LED for each relay for alarm indication: One common warn gas alarm One common alarm gas alarm One common high gas alarm One common fault alarm |
Communication | BACnet output only |
Time Delays | 0, 30, and 45 seconds, and 1 to 99 minutes before and after alarm |
Enclosure | NEMA 4x, cast aluminum #A356.0T6, EMI/RFI protected |
Over-voltage Category | II |
Dimensions | 24.1 x 35.6 x 8.9 cm (9.50” x 14” x 3.5”) |
Weight | 5.2 kg (11.4 lbs) |
If you have any question, please do not hesitate to contact with me online