Top Industrial Automation and Electrical Instrument from HKXYTECH
  • Honeywell Analytics TPPRHWMFNXHXXLZII8421526123 Touchpoint Pro Controller

Honeywell Analytics TPPRHWMFNXHXXLZII8421526123 Touchpoint Pro Controller

2019-03-06 10:16:55

Description:

Centralised or distributed system……

New Products

FXT1-P37 Right Angle Milling Head

FXT1-P37 Right Angle Milling Head - HKXYTECH

FXT1-P24 Right Angle Milling Head

FXT1-P24 Right Angle Milling Head - HKXYTECH

FXT1-P18 Right Angle Milling Head

FXT1-P18 Right Angle Milling Head - HKXYTECH

FXT1-AC Fully Automatic Right Angle Milling Heads

FXT1-AC Fully Automatic Right Angle Milling Heads - HKXYTECH

Assortments

Description

Honeywell Analytics TPPRHWMFNXHXXLZII8421526123 Touchpoint Pro Controller Gas Detection Controllers Industrial Gas Systems

 

SYSTEM

Centralised or distributed system

ENCLOSURE

WALL MOUNT CONTROLLER ENCLOSURE

Dimensions (H x W x D)

600 mm x 600 mm x 300 mm (Mild Steel)

800 mm x 600 mm x 300 mm (Mild Steel)

1200 mm x 600 mm x 300 mm (Mild Steel)

WALL MOUNT REMOTE UNIT ENCLOSURE


Dimensions (H x W x D)

600 mm x 600 mm x 300 mm (Mild Steel)

800 mm x 600 mm x 300 mm (Mild Steel)

19’’ 5U RACK UNIT


Dimensions (H x W x D)

483 mm x 222 mm x 110 mm (Mild Steel)

FLOOR STANDING CABINETS (FRONT OR REAR   ACCESS)

Dimensions (H x W x D)

2000 mm x 800 mm x 600 mm (Mild Steel)

CONTROL MODULE AND USER INTERFACE


LCD Touch Screen

5.7” TFT Colour LCD with LED

Backlight (resistive touch screen)

320 x 240 pixels (QVGA) Resolution

Active area 115.2 mm(H) x 86.4 mm(V)

Front Panel Dimension

483 mm x 222 mm

Operating Temperature

-20°C to +55°C

Storage Temperature

-20°C to +55°C

Operating Humidity

10% to 90% RH (non-condensing)

INPUT SUPPLY

Input Voltage

18-32 Vdc (24 Vdc nominal)

Voltage Ripple

50 mVp-p (maximum)

CONTROLS AND INDICATORS


Front Panel LED

Green Power LED

Red Alarm LED

Yellow Fault LED

Yellow Inhibit LED

Front Panel Buttons

Alarm Accept Push Button, Alarm Reset

Push Button; Alarm Buzzer

Relay Outputs

2 System State Relays

Redundancy

Redundant Control Centre Board (CCB)

Ring Network

EXTERNAL COMMUNICATION

Interfaces

Redundant RS485 Modbus

RTU interface

Ethernet

INPUT/ OUTPUT MODULES

COMMON SPECIFICATIONS

Dimensions (H x W x D)

35.0 mm x 99.5 mm x 114.5 mm

Power Supply

18-32 Vdc (24 Vdc nominal)

DIN rail compatibility

TS-35 / 15

Operating Temperature

Range

-40°C to 55°C

Operating Humidity Range

10 to 90% RH (non-condensing)

Inputs

Up to 16 Input Modules (64 Input   channels) per system

Analogue Input Module 4-20 mA;

4-channels for 2 or 3 wire 20 mA detector   signals

Analogue Input Module mV-Bridge;

4-channels for mV-Bridge signals

Digital Input Module; 4-channels for   switched input devices

Outputs

Up to 32 Output Modules (128 Output   channels) per system Relay Output Module; 4-channels incorporating 4 single   pole

change over (SPCO) relays

Sensors

Catalytic or IR for combustible 4-20 mA   transmitters Electrochemical for toxic and Oxygen Conventional smoke, heat   and fire detectors

COMMUNICATION / POWER RAIL


Description

5, 7, 9, or 10-way Communication /

Power Rail consists of 1 DIN Rail,

1 Ring Coupling Module (RCM) and

5, 7, 9, or 10-way backplanes

Power Supply

Operating voltage range - 18 Vdc to 32   Vdc (double-check)

Power Supply mounted on

Din-Rail

120 W 24 Vdc, 240 W 24 Vdc, 480 W

24 Vdc, Power Supply Redundancy

Module (RDN Module), Uninterruptible

Power Supply Module (UPS)

BACK-UP BATTERY


Description

24 V sealed lead acid battery, 12 Ah

or 27 Ah options

Electrical Connection

2 x 12 Vdc batteries in series

Dimensions (H x W x D)

300 mm x 395 mm x 215 mm

Weight

12 Ah version: 15.7 kg

27 Ah version: 25 kg

APPROVALS

Compliance

Compliance with EMC/RFI

(EN 50270:2006) and LVD

(EN 61010-1:2010)

CSA-C22.2 No. 61010-1-04, UL Std.

No. 61010-1 (2nd Edition)

Advanced requirements

ATEX Performance Approvals -

EN 50271:2010; EN 60079-29-1;

EN 45544-1 /-2 /-3; EN 50104:2010

C22.2 No. 152-M1984, FM Std. 6310 and   6320

Highest level of safety

IEC/EN 61508 and EN 50402 SIL2   certification

 

Similar model codes for your reference :

TPPR–HW–MF–NXHXXL–ZII8421526123, TPPR-V-0842, TPPR-V-1000, TPPR-V-1010, TPPR-V-0501, TPPR-V-1030, TPPR-V-1040, TPPR-V-1050, TPPR-V-0500, TPPR-V-0503, TPPR-V-0504, TPPR-V-0502, TPPR-V-0406, TPPR-V-0405, TPPR-V-2130, TPPR-V-2120, 2400M2501, 2400M2563, 2400M2564

 

If you have any question, please do not hesitate to contact with me online

Contact details :

Shirley Sun

Sales Engineer

HONGKONG XIEYUAN TECH CO., LIMITED

Add : 7-A16, Caishen Commercial Plaza, Hankou Railway Station, Wuhan, China

M : +86-15172506760 (WhatsApp & Wechat) | T : +86-27-85309780  | F : +86-27-85309780

Email : Shirley@whxyauto.com     Skype : 169649423@qq.com

Web : www.hkxytech.com