Honeywell Analytics TPPLBAWA8S8BNNN Touchpoint Plus Controller Gas Detection Controllers
2019-03-05 11:20:49
Description:
Up to 8 channels with base unit, up to 16 channels with expansion unit……
New Products
FXT1-P37 Right Angle Milling Head
FXT1-P37 Right Angle Milling Head - HKXYTECH
FXT1-P24 Right Angle Milling Head
FXT1-P24 Right Angle Milling Head - HKXYTECH
FXT1-P18 Right Angle Milling Head
FXT1-P18 Right Angle Milling Head - HKXYTECH
FXT1-AC Fully Automatic Right Angle Milling Heads
FXT1-AC Fully Automatic Right Angle Milling Heads - HKXYTECH
Assortments
Description
Honeywell Analytics TPPLBAWA8S8BNNN Touchpoint Plus Controller Gas Detection Controllers
GENERAL SPECIFICATION | |
Capacity | Up to 8 channels with base unit, up to 16 channels with expansion unit |
Type of inputs | 2 or 3 wires, mA, mV, max. 15W per channel, max 40W total (with dedicated A/V drive) / 68W total (without dedicated A/V drive) |
Size (wall-mounted version) | 426 mm × 300 mm × 156 mm (16.8” x 11.8” x 6.1”) |
Housing Material | Polycarbonate ABS |
Weight | Max 8.5 kg (18.7 lb), max 17 kg (37.4 lb) with expansion unit |
USER INTERFACE (UI) - CONTROLLER ONLY | |
Display | 7’’ colour LCD touchscreen. Graphic User Interface |
Visual indicators | 3 LEDs for master indicators. LED for each channel. Green: Normal; Yellow: Fault: Inhibit; Red: Alarm |
Audible alarm | ≥ 70dB @ 1m |
Button | Common for reset/mute operation |
Language | English, French, German, Italian, Dutch, Spanish, Portuguese, Russian, Chinese |
POWER SUPPLY* | |
Power AC | 110/220VAC, 50-60Hz Manual switching |
Power DC | 18 to 32 VDC (+/-10%) Typical 24VDC |
Power consumption | Max 105W (including detector and external devices), max 210W with expansion unit |
ENVIRONMENTAL | |
Operating | -10°C to +55°C (14°F to +131°F) continuous, up to 95% RH (non-condensing), IP65 and NEMA 4X |
Storage | Instrument -25°C to +60°C. (-13°F to +140°F), up to 95% RH (non-condensing) |
4~20mA input | 2 or 3 wire, 2/4/8 channel modules, 10/12/16 with expansion unit |
mV input | Catalytic type flammable gas detectors (Honeywell models). 2/4/8 channel modules, 10/12/16 with expansion unit |
Dual Input | 2 channel mA + 2 channel mV module or 4 channel mA + 4 channel mV module |
Relay output | 12 or 24 relay outputs, NO/C/NC changeover, 1.7A@30VDC/250VAC, user configurable - energised/de-energised, latching/non latching, time delay |
4~20mA output | 4 or 8 isolated repeated mA outputs, 0-22mA, 0-100%FSD = 4-20mA |
Common inputs | Remote reset, remote inhibit |
Common outputs | Four powered A/V outputs for alarms and fault, three common alarm outputs |
APPROVALS | |
Electromagnetic Compatibility and Electrical Safety | EMC/RFI (EN 50270:2015) LVD (EN 61010-1:2010) CSA-C22.2 No. 61010-1-04 UL 61010-1 (3rd Edition) and 508 |
Performance** | Designed to meet - EN 50271:2010; EN 60079-29-1:2007; EN 45544-1 /-2 /-3:2015; EN 50104:2010 C22.2 No. 152-M1984, ISA 12.13.01 |
Safety Integrity | Designed to meet IEC 61508:2010 Ed.2 SIL2, EN 50271:2010 |
Hazardous Location | Class I, Division 2, Group A, B, C and D or non-hazardous only |
OTHERS | |
Backup battery | 22.2V Lithium Ion Battery, 2600mAh capacity (>30 minutes for typical system) |
Data logging | Configuration, logged events and data |
Communication | MODBUS TCP, WEB monitoring and MODBUS RTU |
Similar model codes for your reference :
TPPLBAWV8D8BNNN, TPPLBAWA2NNNNNN, TPPLBAWV2NNNNNN, TPPLBAWA4NNNNNN, TPPLBAWV4NNNNNN, TPPLBAWA8NNNNNN, TPPLBAWV8NNNNNN, TPPLBAWA8DNBNNN, TPPLBAWV8DNBNNN, TPPLBAWA8D8NNNN, TPPLBAWV8D8NNNN, TPPLBAWA8D8BNNN, TPPLBAWV8D8BNNN
If you have any question, please do not hesitate to contact with me online
Contact details :
Shirley Sun
Sales Engineer
HONGKONG XIEYUAN TECH CO., LIMITED
Add : 7-A16, Caishen Commercial Plaza, Hankou Railway Station, Wuhan, China
M : +86-15172506760 (WhatsApp & Wechat) | T : +86-27-85309780 | F : +86-27-85309780
Email : Shirley@whxyauto.com Skype : 169649423@qq.com
Web : www.hkxytech.com