Top Industrial Automation and Electrical Instrument from HKXYTECH
  • Honeywell Analytics Sensepoint XCD RFD Remote Flammable Gas Monitor Explosion-Proof Transmitters

Honeywell Analytics Sensepoint XCD RFD Remote Flammable Gas Monitor Explosion-Proof Transmitters

2019-01-09 17:21:39

Description:

3-wire, 4-20mA, transmitter with optional Modbus for use with remotely mounted flammable gas sensors 705 and 705HT……

New Products

FXT1-P37 Right Angle Milling Head

FXT1-P37 Right Angle Milling Head - HKXYTECH

FXT1-P24 Right Angle Milling Head

FXT1-P24 Right Angle Milling Head - HKXYTECH

FXT1-P18 Right Angle Milling Head

FXT1-P18 Right Angle Milling Head - HKXYTECH

FXT1-AC Fully Automatic Right Angle Milling Heads

FXT1-AC Fully Automatic Right Angle Milling Heads - HKXYTECH

Assortments

Description

Honeywell Analytics Sensepoint XCD RFD Remote Flammable Gas Monitor Explosion-Proof Transmitters Industrial Gas Systems

 

Use

3-wire, 4-20mA, transmitter with optional   Modbus for use with remotely mounted flammable gas sensors 705 and 705HT

Electrical

Input Voltage Range

16 to 32VDC (24VDC nominal)

Max Power Consumption

Max 5 Watts. at 24Vdc (see section 2   regarding maximum in rush current)

Current Output

4-20mA (Source or Sink)

0.0<1.0 mA: Fault

4.0 mA to 20.0 mA: Inhibit (during   configuration/user settings)

22.0 mA: Maximum over range

Terminals

15 x screw terminals suitable for wire   diameter 0.5mm2 to 2.5mm 2 (20AWG to 13AWG)

Relays

3 x 5A@250VAC. Selectable normally open   or normally closed (switch) and energized/de-energized (programmable)

Communication

RS485, Modbus RTU

Construction

Material

Epoxy painted aluminium alloy or 316   Stainless Steel

Weight (approx)

Aluminium Alloy LM25: 4.4lbs

316 Stainless Steel: 11lbs

Mounting

Pole or wall mounting

Cable Entries

2 x ¾” NPT

Sensor Entries

¾” NPT

Environmental


IP Rating

IP66 in accordance with EN60529:1992,   NEMA 4X (Tested by third party laboratory)

Operating Temperature

-40ºF to +149ºF (-40ºC to +65ºC)

Operating Humidity

Continuous 20-90%RH (non condensing),   Intermittent 10-99%RH (non condensing)

Operating Pressure

90-110kPa

Storage Conditions

-13°F to +149°F (-25°C to +65°C)

Certification


US

cCSAus approved for Class I, Division 1,   Groups B, C & D Hazardous Locations. Performance approved to the   following standards; ANSI/ISA-12.13.01

Canada

cCSAus approved for Class I, Division 1,   Groups B, C & D Hazardous Locations. Performance approved to the   following standards;

C22.2 No. 152-M1984

Performance

C22.2-152, ANSI/ISA 121301

 

If you have any question, please do not hesitate to contact with me online

Contact details :

Shirley Sun

Sales Engineer

HONGKONG XIEYUAN TECH CO., LIMITED

Add : 7-A16, Caishen Commercial Plaza, Hankou Railway Station, Wuhan, China

M : +86-15172506760 (WhatsApp & Wechat) | T : +86-27-85309780  | F : +86-27-85309780

Email : Shirley@whxyauto.com     Skype : 169649423@qq.com

Web : www.hkxytech.com