Top Industrial Automation and Electrical Instrument from HKXYTECH
  • Yokogawa AAI135-S00 Current Input Module and Current I/O Module Isolated Channels

Yokogawa AAI135-S00 Current Input Module and Current I/O Module Isolated Channels

2018-12-27 17:30:00

Description:

AAI135-S00……

New Products

Orbinox VG SERIES 61 Slurry knife gate valve

Orbinox SERIES 61 (VG) model knife gate valve is a wafer type valve equipped with two metal reinforced rubber sleeves,designed for applications with abrasive slurries.

Crosby J-Series Direct Spring Pressure Relief Valves

J-Series valves provide high quality and dependable overpressure protection for air, gas, steam, vapor, liquid and two-phase applications in one simple design. Now available with two new to the world technologies, Balanced Diaphragm and Bellows Leak Detection.

Vanessa Series 30,000 Cryogenic Triple Offset Valve

The Vanessa Series 30,000 Cryogenic Triple Offset Valve is a virtually maintenance-free valve with tightness, operability and torque demand unaffected by cryogenic conditions and severe temperature fluctuations.

Sempell Model SOT High pressure steam safety valve

The Sempell Model SOT is a high-pressure steam safety valve designed for boiler protection and steam system safety.

Assortments

Description

Yokogawa AAI135-S00 Current Input Module and Current I/O Module Isolated Channels

 

Items

Specifications

Model

AAI135 (*1)

Number of I/O channels

8-channel input, isolated channels

I/O signal

4 to 20 mA

Allowable input current

25 mA

Withstanding voltage

Between input and system:

 500 V AC, for 1 minute

Between input channels:

 500 V AC, for 1 minute (*2)

Input

resistance

Power ON

290 Ω (at 20 mA) to 450 Ω (at 4 mA) (*3)

Power OFF

500 kΩ or larger

Allowable load resistance


Circuit-open detection


Accuracy

±16 µA

Data update period

10 ms

Transmitter power supply

15.0 V or higher (at 20 mA)

29.3 V or less (at 0 mA) (*5)

Temperature drift

±16 µA/10 °C

Maximum current

consumption

360 mA (5 V DC), 450 mA (24 V DC)

Weight

0.3 kg

External connection

Pressure clamp terminal, MIL connector   cable, dedicated cable (KS1)

HART communication (*6)

Available

*1: A Zener barrier is not allowed to be connected with this module. Use an isolation barrier when the module is used in

intrinsically safe applications.

*2: When the ML connector cable is used, the withstanding voltage depends on the electrical specifications of the cable.

*3: The module input resistance viewed from the terminals depends on the current strength as calculated as below:

250 Ω + voltage drop in the input protection circuit/current value

F06E.ai

*5: This voltage is generated between the connecting terminals for 2-wire transmitters for this module. When calculating the

minimum operating voltage for transmitters, consider to allow margins for voltage drop in external wiring.

*6: When this module is installed to a ER bus node unit with HART function, the EB401 firmware must be rev. 2 or later.

 

Similar model codes for your reference :

AAI135-S00, AAI135-S50, AAI141-H00, AAI141-H53, AAI141-S00, AAI141-S03, AAI141-S50, AAI143-H00, AAI143-H50, AAI143-HE3, AAI143-S50, AAI143-S51, AAI543-H00, AAI543-H03, AAI543-H50, AAI543-H53, AAI543-H60, AAI543-S00, AAI543-S50, AAI841, AAI841-H50, AAI841-S00

 

If you have any question, please do not hesitate to contact with me online

Contact details :

Shirley Sun

Sales Engineer

HONGKONG XIEYUAN TECH CO., LIMITED

Add : 7-A16, Caishen Commercial Plaza, Hankou Railway Station, Wuhan, China

M : +86-15172506760 (WhatsApp & Wechat) | T : +86-27-85309780  | F : +86-27-85309780

Email : Shirley@whxyauto.com     Skype : 169649423@qq.com

Web : www.hkxytech.com