Top Industrial Automation and Electrical Instrument from HKXYTECH
  • RAE SYSTEMS by Honeywell ToxiRAE 3 Portable High Range CO Monitor 0 to 1999PPM G01-0103-100

RAE SYSTEMS by Honeywell ToxiRAE 3 Portable High Range CO Monitor 0 to 1999PPM G01-0103-100

2018-08-30 22:58:59

Description:

RAE SYSTEMS by Honeywell ToxiRAE 3 Full-featured, single-gas monitor for CO and H2S……

New Products

Siemens 6DL1193-6TP00-0DH1 SIMATIC ET 200SP HA

Siemens 6DL1193-6TP00-0DH1 SIMATIC ET 200SP HA, Terminal block, Type H1, 32 push-in terminals, internal reference temperature New load group, width: 22.5 mm.

Siemens 6DL1193-6TP00-0BH1 SIMATIC ET 200SP HA

Siemens 6DL1193-6TP00-0BH1 SIMATIC ET 200SP HA, Terminal block, Type H1, 32 push-in terminals, internal reference temperature Width: 22.5 mm.

Siemens 6DL1193-6GC00-0NN0 SIMATIC ET 200SP HA

Siemens 6DL1193-6GC00-0NN0 SIMATIC ET 200SP HA, carrier module 8-fold carrier for holding 8 I/O modules of the ET 200SP HA.

Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA

Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA, carrier module 2-fold carrier for holding 2 I/O modules of the ET 200SP HA.

Assortments

Description

RAE SYSTEMS by Honeywell ToxiRAE 3 Portable High Range CO Monitor 0 to 1999PPM G01-0103-100


RAE SYSTEMS by Honeywell ToxiRAE 3 Full-featured, single-gas monitor for CO and H2S

RAE SYSTEMS by Honeywell ToxiRAE 3 Portable Single-Gas Monitor H2S Monitor G01-0102-000

RAE SYSTEMS by Honeywell ToxiRAE 3 Portable Single-Gas Monitor H2S Detector G01-0102-010

RAE SYSTEMS by Honeywell ToxiRAE 3 Portable Single-Gas Monitor CO Detector G01-0101-000

RAE SYSTEMS by Honeywell ToxiRAE 3 Portable Single-Gas Monitor CO Monitor G01-0101-010

RAE SYSTEMS by Honeywell ToxiRAE 3 Portable Single-Gas Monitor CO Monitor 0 to 500 PPM G01-0101-100

RAE SYSTEMS by Honeywell ToxiRAE 3 Portable Single-Gas Monitor CO Monitor 0 to 1999PPM G01-0103-000

RAE SYSTEMS by Honeywell ToxiRAE 3 Portable High Range CO Monitor 0 to 1999PPM G01-0103-010

This portable single-gas monitor is designed to keep workers safe against the threat of carbon monoxide (CO) and hydrogen sulfide (H2S). The ToxiRAE 3’s high-performance, three-electrode sensor delivers the fastest possible response time. When used with the AutoRAE Lite bump test and calibration station, it provides a low total cost of ownership (TCO) to organizations that are looking to protect workers and deliver worksite CO and H2S personal detection compliance. With its water and dust-resistant housing, and three-alarm capability, it’s a valuable tool for ensuring workers are aware of the presence of CO or H2S.



Key Features:

Fully featured single-gas monitor

0.1ppm resolution on Hydrogen Sulfide (H2S) sensor

Carbon monoxide (CO) sensor

Can record STEL, TWA, high and low alarms

High-performance sensor for fastest possible response time

Compatible with AutoRAE Lite bump test and calibration station

Large, easy-to-read display

Lightweight, easy to wear and use

Logs up to 10 events

Water- and dust-resistant

Audible, visual, and vibration alarm


Applications:

Emergency Response

Exploration

Fracking

Hazmat Response

Plant Shutdown & Turn-Around

Residential Calls

Worker Exposure



Specifications

Detector Specifications

Size 3.4" x 2.2" x 0.8" (8.6 cm x 5.5 cm x 2.0 cm)

Weight 3.5 oz (99.4 g)

Battery User-replaceable 2/3 AA high-capacity lithium

Alarms:

1) 95 dB typical (at 30 cm) buzzer and flashing red LED to indicate exceeded preset limits

2) High: Displays “High” and emits 3 beeps and flashes per second

3) Low: Displays “Low” and emits 2 beeps and flashes per second

4) STEL: Displays “STEL” and emits 1 beep and flash per second

5) TWA: Displays “TWA” and emits 1 beep and flash per second

6) Vibration alarm

7) 6-LED visible alarm

Data logging 10 events

Response time T90 < 12 seconds

IP Rating IP-67

EMI/RFI:

Highly resistant to EMI/RFI.

Compliant with EMC directive 2004/108/ECCertification 

cCSAus: C1D1, Groups A, B, C, D, T4

ATEX: II 1G Ex ia IIC T4 Ga

IECEX: Ex ia IIC T4 Ga

Operating Temperature:

Continuous: -4° to 140° F (-20° to +60° C)

Intermittent: -22° to 140° F (-30° to +60° C)Humidity 0 to 95% relative humidity (non-condensing)

Warranty 2 years, including sensor and battery if used within specs

Calibration Two-point calibration for zero and span

Sensor   Specifications
GasGas Range (ppm)Resolution (ppm)
H2S0 to 1000.1
CO0 to 5001
CO0 to 19991


ToxiRAE 3 Ordering Options

Pack of 1: 

ToxiRAE 3 with specified sensor:

2/3 AA lithium battery

One mini-CD with instruction manual and training materials

Alligator clip

Calibration adapter


Pack of 10:

10 ToxiRAE 3 monitors with specified sensor

2mini-CDswith instructionmanual and trainingmaterials

2 calibration adapters

10 alligator clips


Pack of 100:

10 packs of 10


Accessories (optional)

AutoRAE Lite Automatic Test and Calibration Station

Ordering   Information
MonitorPack of 1Pack of 10Pack of 100
H2SG01-0102-000G01-0102-010G01-0102-100
CO          Low rangeG01-0101-000G01-0101-010G01-0101-100
CO         High rangeG01-0103-000G01-0103-010G01-0103-100




AutoRAE Lite
Bump Test and   Calibration StationT01-0100-000

Ava  Wong  

Sales  Manager

HONGKONG XIEYUAN TECH CO., LIMITED

M:  +86-15602323637 (WhatsApp & Wechat) |  T:  +86-27-85581877 | F: +86-27-85309780

Email:  ava.wong@hkxytech.com  Skype:  ava.huang4

Web:  www.gasanalytics.net