Top Industrial Automation and Electrical Instrument from HKXYTECH
  • Pepperl Fuchs KFA6-SR2-Ex1.W Explosion Protection Intrinsic Safety Isolated Barriers Switch Amplifiers

Pepperl Fuchs KFA6-SR2-Ex1.W Explosion Protection Intrinsic Safety Isolated Barriers Switch Amplifiers

2018-08-01 11:43:38

Description:

1-channel isolated barrier 230 V AC supply Dry contact or NAMUR inputs ……

New Products

Siemens 6DL1193-6TP00-0DH1 SIMATIC ET 200SP HA

Siemens 6DL1193-6TP00-0DH1 SIMATIC ET 200SP HA, Terminal block, Type H1, 32 push-in terminals, internal reference temperature New load group, width: 22.5 mm.

Siemens 6DL1193-6TP00-0BH1 SIMATIC ET 200SP HA

Siemens 6DL1193-6TP00-0BH1 SIMATIC ET 200SP HA, Terminal block, Type H1, 32 push-in terminals, internal reference temperature Width: 22.5 mm.

Siemens 6DL1193-6GC00-0NN0 SIMATIC ET 200SP HA

Siemens 6DL1193-6GC00-0NN0 SIMATIC ET 200SP HA, carrier module 8-fold carrier for holding 8 I/O modules of the ET 200SP HA.

Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA

Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA, carrier module 2-fold carrier for holding 2 I/O modules of the ET 200SP HA.

Assortments

Description

Pepperl Fuchs KFA6-SR2-Ex1.W Explosion Protection Products Intrinsic Safety Barriers Isolated Barriers K-System Switch Amplifiers

 

1-channel isolated barrier

230 V AC supply

Dry contact or NAMUR inputs

Relay contact output

Line fault detection (LFD)

Reversible mode of operation

Up to SIL 2 acc. to IEC 61508/IEC 61511

 

Datasheet excerpt: Technical data of KFA6-SR2-Ex1.W

 

General   specifications


Signal type

Digital Input

Functional   safety related parameters


Safety Integrity Level (SIL)

SIL 2

Supply


Connection

terminals 14, 15

Rated voltage

207 ... 253 V AC, 45 ... 65 Hz

Power dissipation

1 W

Power consumption

max. 1 W

Input


Connection side

field side

Connection

terminals 1+, 2+, 3-

Rated values

acc. to EN 60947-5-6 (NAMUR)

Open circuit voltage/short-circuit   current

approx. 8 V DC / approx. 8 mA

Switching point/switching hysteresis

1.2 ... 2.1 mA / approx. 0.2 mA

Line fault detection

breakage I ≤ 0.1 mA , short-circuit I   > 6 mA

Pulse/Pause ratio

min. 20 ms / min. 20 ms

 

Similar model codes for your reference :

KFA6-DU-Ex1.D

KFA6-DWB-Ex1.D

KFA6-ER-1.5 

KFA6-ER-1.6

KFA6-ER-1.W.LB  

KFA6-ER-2.W.LB  

KFA6-ER-Ex1.W.LB

KFA6-SOT2-Ex2

KFA6-SR-2.3L

KFA6-SR-2.3L.FA

KFA6-SR2-Ex1.W

KFA6-SR2-Ex1.W.LB

KFA6-SR2-Ex2.W

KFA6-SR2-Ex2.W.IR

KFA6-STR-1.24.500

KFA6-STR-1.24.4

 

If you have any question, please do not hesitate to contact with me online

Contact details :

Shirley Sun

Sales Engineer

HONGKONG XIEYUAN TECH CO., LIMITED

Add : 7-A16, Caishen Commercial Plaza, Hangkou Railway Station, Wuhan, China

M : +86-15172506760 (WhatsApp & Wechat) | T : +86-27-85309780  | F : +86-27-85309780

Email : Shirley@whxyauto.com     Skype : 169649423@qq.com

Web : www.hkxytech.com