Top Industrial Automation and Electrical Instrument from HKXYTECH
  • Pepperl Fuchs KFA6-SOT2-Ex2 Explosion Protection Products Intrinsic Safety Barriers Isolated Barriers Switch Amplifiers

Pepperl Fuchs KFA6-SOT2-Ex2 Explosion Protection Products Intrinsic Safety Barriers Isolated Barriers Switch Amplifiers

2018-07-31 17:17:26

Description:

2-channel isolated barrier 230 V AC supply Dry contact or NAMUR inputs Passive transistor output, non-polarized ……

New Products

Orbinox VG SERIES 61 Slurry knife gate valve

Orbinox SERIES 61 (VG) model knife gate valve is a wafer type valve equipped with two metal reinforced rubber sleeves,designed for applications with abrasive slurries.

Crosby J-Series Direct Spring Pressure Relief Valves

J-Series valves provide high quality and dependable overpressure protection for air, gas, steam, vapor, liquid and two-phase applications in one simple design. Now available with two new to the world technologies, Balanced Diaphragm and Bellows Leak Detection.

Vanessa Series 30,000 Cryogenic Triple Offset Valve

The Vanessa Series 30,000 Cryogenic Triple Offset Valve is a virtually maintenance-free valve with tightness, operability and torque demand unaffected by cryogenic conditions and severe temperature fluctuations.

Sempell Model SOT High pressure steam safety valve

The Sempell Model SOT is a high-pressure steam safety valve designed for boiler protection and steam system safety.

Assortments

Description

Pepperl Fuchs KFA6-SOT2-Ex2 Explosion Protection Products Intrinsic Safety Barriers Isolated Barriers K-System Switch Amplifiers

 

2-channel isolated barrier

230 V AC supply

Dry contact or NAMUR inputs

Passive transistor output, non-polarized

Line fault detection (LFD)

Reversible mode of operation

Up to SIL 2 acc. to IEC 61508

 

Datasheet excerpt: Technical data of KFA6-SOT2-Ex2

General   specifications


Signal type

Digital Input

Functional   safety related parameters


Safety Integrity Level (SIL)

SIL 2

Supply


Connection

terminals 14, 15

Rated voltage

207 ... 253 V AC, 45 ... 65 Hz

Power dissipation

1 W

Power consumption

max. 1.5 W

Input


Connection side

field side

Connection

terminals 1+, 2+, 3-; 4+, 5+, 6-

Rated values

acc. to EN 60947-5-6 (NAMUR), see system   description for electrical data

Open circuit voltage/short-circuit   current

approx. 8 V DC / approx. 8 mA

Switching point/switching hysteresis

1.2 ... 2.1 mA / approx. 0.2 mA

Line fault detection

breakage I ≤ 0.1 mA , short-circuit I   > 6 mA

 

Similar model codes for your reference :

KFA6-DU-Ex1.D

KFA6-DWB-Ex1.D

KFA6-ER-1.5

KFA6-ER-1.6

KFA6-ER-1.W.LB

KFA6-ER-2.W.LB

KFA6-ER-Ex1.W.LB

KFA6-SOT2-Ex2

KFA6-SR-2.3L

KFA6-SR-2.3L.FA

KFA6-SR2-Ex1.W

KFA6-SR2-Ex1.W.LB

KFA6-SR2-Ex2.W

KFA6-SR2-Ex2.W.IR

KFA6-STR-1.24.500

KFA6-STR-1.24.4

 

If you have any question, please do not hesitate to contact with me online

Contact details :

Shirley Sun

Sales Engineer

HONGKONG XIEYUAN TECH CO., LIMITED

Add : 7-A16, Caishen Commercial Plaza, Hangkou Railway Station, Wuhan, China

M : +86-15172506760 (WhatsApp & Wechat) | T : +86-27-85309780  | F : +86-27-85309780

Email : Shirley@whxyauto.com     Skype : 169649423@qq.com

Web : www.hkxytech.com