Top Industrial Automation and Electrical Instrument from HKXYTECH
  • Yokogawa EJX310A-EMS4G-U12EN/FF1/D1 Traditional-mount Absolute Pressure Transmitter

Yokogawa EJX310A-EMS4G-U12EN/FF1/D1 Traditional-mount Absolute Pressure Transmitter

2018-07-16 10:03:16

Description:

The EJX310A is the traditional-mount Absolute Pressure Transmitter in the series.……

New Products

Orbinox VG SERIES 61 Slurry knife gate valve

Orbinox SERIES 61 (VG) model knife gate valve is a wafer type valve equipped with two metal reinforced rubber sleeves,designed for applications with abrasive slurries.

Crosby J-Series Direct Spring Pressure Relief Valves

J-Series valves provide high quality and dependable overpressure protection for air, gas, steam, vapor, liquid and two-phase applications in one simple design. Now available with two new to the world technologies, Balanced Diaphragm and Bellows Leak Detection.

Vanessa Series 30,000 Cryogenic Triple Offset Valve

The Vanessa Series 30,000 Cryogenic Triple Offset Valve is a virtually maintenance-free valve with tightness, operability and torque demand unaffected by cryogenic conditions and severe temperature fluctuations.

Sempell Model SOT High pressure steam safety valve

The Sempell Model SOT is a high-pressure steam safety valve designed for boiler protection and steam system safety.

Assortments

Description

Yokogawa EJX310A-EMS4G-U12EN/FF1/D1 Traditional-mount Absolute Pressure Transmitter

 

The EJX-A series is Yokogawa's premium performance line of DPharp transmitters. Released in 2004, it offers the performance and stability needed in demanding applications. The EJX-A series performance makes it a thoroughbred of the DPharp family of pressure transmitters.

 

The EJX310A is the traditional-mount Absolute Pressure Transmitter in the series.

 

EJX310A features include:

± 0.075% Accuracy

± 0.2% per 15 years Stability

90 ms Response Time

Exida and TUV SIL 2/3 Certification

LPS (Local Parameter Setting)

 

EJX310A Overview

Measurement   Types


Primary   Variable

Absolute Pressure

Reference   Accuracy


Primary   Variable

±0.075% of Span (L-Capsule)

±0.04% of Span (M, A, and B Capsule)

Stability   (All Normal Operating Conditions)


Primary   Variable

±0.2% of URL per 10 years

Response   Time


Primary   Variable

90ms

Rangeability


Primary   Variable

L-Capsule: 20:1

M-Capsule: 100:1

A and B Capsule: 200:1

Burst   Pressure (Absolute)


All   Capsules

10,000 psi (69 MPa)

Specification   Conformance


EJX-A   Series

±3σ

 

Similar mode codes for your reference :

EJX310A-EMS4G-U12EN/FF1/D1

EJX310A-EMS4G-U121

EJA310A-ELS4A-92DA

EJA310A-ELS4A-92DN

EJA310A-ELS4A-92EA

EJA310A-ELS4A-92EN

EJA310A-ELS4A-92DC

EJA310A-ELS4A-92DD

EJA310A-ELS4A-22DA

EJA310A-ELS4A-22DN

EJA310A-ELS4A-22EA

EJA310A-ELS4A-22EN

EJA310A-ELS4A-22DC

EJA310A-ELS4A-22DD

EJA310A-ELS4A-97DA

EJA310A-ELS4A-97DN

EJA310A-ELS4A-97EA

EJA310A-ELS4A-97EN

EJA310A-ELS4A-97DC

EJA310A-ELS4A-97DD

EJA310A-EMS4A-92DA

EJA310A-EMS4A-92DN

EJA310A-EMS4A-92EA

EJA310A-EMS4A-92EN

EJA310A-EMS4A-92DC

EJA310A-EMS4A-92DD

EJA310A-EMS4A-22DA

EJA310A-EMS4A-22DN

EJA310A-EMS4A-22EA

EJA310A-EMS4A-22EN

EJA310A-EMS4A-22DC

EJA310A-EMS4A-22DD

EJA310A-EMS4A-97DA

EJA310A-EMS4A-97DN

EJA310A-EMS4A-97EA

EJA310A-EMS4A-97EN

EJA310A-EMS4A-97DC

EJA310A-EMS4A-97DD

EJA310A-EAS4A-92DA

EJA310A-EAS4A-92DN

EJA310A-EAS4A-92EA

EJA310A-EAS4A-92EN

EJA310A-EAS4A-92DC

EJA310A-EAS4A-92DD

EJA310A-EAS4A-22DA

EJA310A-EAS4A-22DN

EJA310A-EAS4A-22EA

EJA310A-EAS4A-22EN

EJA310A-EAS4A-22DC

EJA310A-EAS4A-22DD

EJA310A-EAS4A-97DA

EJA310A-EAS4A-97DN

EJA310A-EAS4A-97EA

EJA310A-EAS4A-97EN

EJA310A-EAS4A-97DC

EJA310A-EAS4A-97DD

EJA310A-DLS4A-92DA

EJA310A-DLS4A-92DN

EJA310A-DLS4A-92EA

EJA310A-DLS4A-92EN

EJA310A-DLS4A-92DC

EJA310A-DLS4A-92DD

EJA310A-DLS4A-22DA

EJA310A-DLS4A-22DN

EJA310A-DLS4A-22EA

EJA310A-DLS4A-22EN

EJA310A-DLS4A-22DC

EJA310A-DLS4A-22DD

EJA310A-DLS4A-97DA

EJA310A-DLS4A-97DN

EJA310A-DLS4A-97EA

EJA310A-DLS4A-97EN

EJA310A-DLS4A-97DC

EJA310A-DLS4A-97DD

EJA310A-DMS4A-92DA

EJA310A-DMS4A-92DN

EJA310A-DMS4A-92EA

EJA310A-DMS4A-92EN

EJA310A-DMS4A-92DC

EJA310A-DMS4A-92DD

EJA310A-DMS4A-22DA

EJA310A-DMS4A-22DN

EJA310A-DMS4A-22EA

EJA310A-DMS4A-22EN

EJA310A-DMS4A-22DC

EJA310A-DMS4A-22DD

EJA310A-DMS4A-97DA

EJA310A-DMS4A-97DN

EJA310A-DMS4A-97EA

EJA310A-DMS4A-97EN

EJA310A-DMS4A-97DC

EJA310A-DMS4A-97DD

EJA310A-DAS4A-92DA

EJA310A-DAS4A-92DN

EJA310A-DAS4A-92EA

EJA310A-DAS4A-92EN

EJA310A-DAS4A-92DC

EJA310A-DAS4A-92DD

EJA310A-DAS4A-22DA

EJA310A-DAS4A-22DN

EJA310A-DAS4A-22EA

EJA310A-DAS4A-22EN

EJA310A-DAS4A-22DC

EJA310A-DAS4A-22DD

EJA310A-DAS4A-97DA

EJA310A-DAS4A-97DN

EJA310A-DAS4A-97EA

EJA310A-DAS4A-97EN

EJA310A-DAS4A-97DC

EJA310A-DAS4A-97DD

 

If you have any question, please do not hesitate to contact with me online

Contact details :

Shirley Sun

Sales Engineer

HONGKONG XIEYUAN TECH CO., LIMITED

Add : 7-A16, Caishen Commercial Plaza, Hangkou Railway Station, Wuhan, China

M : +86-15172506760 (WhatsApp & Wechat) | T : +86-27-85309780  | F : +86-27-85309780

Email : Shirley@whxyauto.com     Skype : 169649423@qq.com

Web : www.hkxytech.com