Model 990.29
2015-06-17 21:19:29
Description:
Flanged Process Connection, Diaphragm Seals Flange-Type Seals with Extended Diaphragm……
New Products
Siemens 6DL1193-6TP00-0DH1 SIMATIC ET 200SP HA
Siemens 6DL1193-6TP00-0DH1 SIMATIC ET 200SP HA, Terminal block, Type H1, 32 push-in terminals, internal reference temperature New load group, width: 22.5 mm.
Siemens 6DL1193-6TP00-0BH1 SIMATIC ET 200SP HA
Siemens 6DL1193-6TP00-0BH1 SIMATIC ET 200SP HA, Terminal block, Type H1, 32 push-in terminals, internal reference temperature Width: 22.5 mm.
Siemens 6DL1193-6GC00-0NN0 SIMATIC ET 200SP HA
Siemens 6DL1193-6GC00-0NN0 SIMATIC ET 200SP HA, carrier module 8-fold carrier for holding 8 I/O modules of the ET 200SP HA.
Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA
Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA, carrier module 2-fold carrier for holding 2 I/O modules of the ET 200SP HA.
Assortments
Description
Applications
Chemical process industry
Petrochemical industry
Suitable for corrosive, highly viscous, crystallising or hot pressure media
For thick-walled or isolated tanks and pipelines
Special Features
Flange with an extended welded diaphragm with contoured diaphragm bed
Available for all standard dimensions and nominal diameters
With special materials all wetted parts of the selected material
Description
Process connection
Flanges DN 50, 80, 100, 125 following EN 1092-1, sealing face form B1 or NPS 2", 3", 4", 5" per ASME B 16.5, RF 125 ... 250 AA
Pressure rating
See table (reverse side)
Suitable pressure ranges
25 mbar and up, depending on diaphragm size and process conditions
Material of wetted parts
Stainless steel 316L
Diaphragm extension
50, 100, 150 or 200 mm
Instrument connection
Material stainless steel 316L, axial weld-in connection or adaptor G ½ female per EN 837-1, welded to capillary
Capillary extension
Axial entry capillary of stainless steel 1.4571, welded to body, armoured, armour material stainless steel 1.4301 Standard extensions: 1, 1.6, 2.5, 4, 5, 6, 7, 8 m Minimum curve radius: 30 mm