YOKOGAWA ESD SAI143-S53 This GS describes the hardware specifications of the analog I/O modules that can be mounted on the safety node unit and the safety control unit.……

YOKOGAWA ESD SAI143-S53 Place of Origin: Singapore,Yokogawa original packing, by carton

New Products

Orbinox VG SERIES 61 Slurry knife gate valve

Orbinox SERIES 61 (VG) model knife gate valve is a wafer type valve equipped with two metal reinforced rubber sleeves,designed for applications with abrasive slurries.

Crosby J-Series Direct Spring Pressure Relief Valves

J-Series valves provide high quality and dependable overpressure protection for air, gas, steam, vapor, liquid and two-phase applications in one simple design. Now available with two new to the world technologies, Balanced Diaphragm and Bellows Leak Detection.

Vanessa Series 30,000 Cryogenic Triple Offset Valve

The Vanessa Series 30,000 Cryogenic Triple Offset Valve is a virtually maintenance-free valve with tightness, operability and torque demand unaffected by cryogenic conditions and severe temperature fluctuations.

Sempell Model SOT High pressure steam safety valve

The Sempell Model SOT is a high-pressure steam safety valve designed for boiler protection and steam system safety.

Assortments

Description

YOKOGAWA ESD Analog Input Module SAI143-S53 


n STANDARD SPECIFICATIONS

 

l Current Input Module

 

This module inputs 4 to 20 mA signals from the field.

 

The SAI143 can be made dual redundant.

 


Item

Specifications


Model


SAI143 (*1)


Number of input channels

16-channel, module isolation (*5)


Rated input range

4 to 20 mA


Permissible input range

0 to 25 mA


Input impedance during Power-ON

250 Ω+ Voltage drop in the   input protection circuit inside the module

(*6)



Current value





Input impedance during Power-OFF

500 kΩ minimum


Rated accuracy

SAI143-S : ±16 µA (Input range 1 to 23 mA)


SAI143-H : ±16 µA (Input range 0.05 to 23 mA)   (*3) (*4)





Data update frequency

40 ms


Temperature drift

±16 µA/10 °C


Transmitter power supply

16.15 V minimum (at 20 mA)


26.4 V maximum (at 0 mA)




(Output current limit: 25 mA)






2/4-wire setting

Individual channel setting


Changed by setting pins








Withstand voltage

1.5 kV AC between input signal and system for   1 minute (*2)


Maximum current consumption

5 V system: 320 mA,


24 V system: 550 mA





Weight


Approx. 0.34 kg (For pressure clamp terminal   block or MIL cable)



Approx. 0.39 kg (With signal cable interface   adapter)









External connection

Pressure clamp terminal


MIL cable




Dedicated signal cable





Support PRM

Available (SAI143-H)



YOKOGAWA ESD Analog Input Module SAI143-S53 


 MODEL AND SUFFIX CODES



Description

Model

SAI143

Analog Input Module (4 to 20 mA, 16-channel, module isolation)

 

 

 

 

 

Suffix Codes

-S

Standard type

-H

With HART communication [Release: R1.02.00] (*1)

5

For pressure clamp terminal block or MIL cable with no explosion protection

6

With signal cable interface adapter and no explosion protection (*2)

E

For pressure clamp terminal block or MIL cable with explosion protection

F

With signal cable interface adapter and explosion protection (*2)

3

With ISA Standard G3 and temperature (-20 to 70 ºC)

C

With ISA Standard G3 and high-density installation (-20 to 70 ºC) (*5)

 

 

 

 

 

 

Option Codes

 

/A4S00

With pressure clamp terminal block for analog

[Model: STA4S-00]

 

/A4S10

With pressure clamp terminal block for analog (with surge absorber) [Model: STA4S-10]

 

/A4D00

With dual-redundant pressure clamp terminal block for analog (*3) [Model: STA4D-00]

 

/A4D10

With dual-redundant pressure clamp terminal block for analog (with surge absorber) (*3) [Part name: STA4D-10]

/PRP

With prevention pin of false insertion (*4)

 

/CCC01

With connector cover for MIL cable (for flat ribbon cable) [Model: SCCC01]




ORDERING INFORMATION

Specify the model and suffix codes.

For selecting the right products for explosion protection, please refer to TI 32S01J30-01E without fail.


SAI143 Analog Input Module (4 to 20 mA, 16-channel, module isolation)

SAI143-S53/A4S00 , SAI143-S53/A4S10 , SAI143-S53/A4D00 , SAI143-S53/A4D10 ,SAI143-S53/PRP, SAI143-S53/CCC01

SAI143-S63/A4S00 , SAI143-S63/A4S10 , SAI143-S63/A4D00 , SAI143-S63/A4D10 ,SAI143-S63/PRP, SAI143-S63/CCC01

SAI143-SE3/A4S00 , SAI143-SE3/A4S10 , SAI143-SE3/A4D00 , SAI143-SE3/A4D10 ,SAI143-SE3/PRP, SAI143-SE3/CCC01

SAI143-SF3/A4S00 , SAI143-SF3/A4S10 , SAI143-SF3/A4D00 , SAI143-SF3/A4D10 ,SAI143-SF3/PRP, SAI143-SF3/CCC01

SAI143-S5C/A4S00 , SAI143-S5C/A4S10 , SAI143-S5C/A4D00 , SAI143-S5C/A4D10 ,SAI143-S5C/PRP, SAI143-S5C/CCC01

SAI143-S6C/A4S00 , SAI143-S6C/A4S10 , SAI143-S6C/A4D00 , SAI143-S6C/A4D10 ,SAI143-S6C/PRP, SAI143-S6C/CCC01

SAI143-SEC/A4S00 , SAI143-SEC/A4S10 , SAI143-SEC/A4D00 , SAI143-SEC/A4D10 ,SAI143-SEC/PRP, SAI143-SEC/CCC01

SAI143-SFC/A4S00 , SAI143-SFC/A4S10 , SAI143-SFC/A4D00 , SAI143-SFC/A4D10 ,SAI143-SFC/PRP, SAI143-SFC/CCC01