Top Industrial Automation and Electrical Instrument from HKXYTECH
  • Yokogawa RTD Input Module AAR181-S00

Yokogawa RTD Input Module AAR181-S00

2016-03-22 20:57:12

Description:

Yokogawa RTD Input Module AAR181-S00,Yokogawa Analog I/O modules function as signal converters; by inputting field analog signals into these modules . AAR181A, AAT141 These modules receive signals from mV, thermocouple (TC), and RTD. They can be used in dual-redundant ……

Yokogawa RTD Input Module AAR181-S00,Yokogawa original packing, by carton,Place of Origin: Indonesia

New Products

Siemens 6DL1193-6TP00-0DH1 SIMATIC ET 200SP HA

Siemens 6DL1193-6TP00-0DH1 SIMATIC ET 200SP HA, Terminal block, Type H1, 32 push-in terminals, internal reference temperature New load group, width: 22.5 mm.

Siemens 6DL1193-6TP00-0BH1 SIMATIC ET 200SP HA

Siemens 6DL1193-6TP00-0BH1 SIMATIC ET 200SP HA, Terminal block, Type H1, 32 push-in terminals, internal reference temperature Width: 22.5 mm.

Siemens 6DL1193-6GC00-0NN0 SIMATIC ET 200SP HA

Siemens 6DL1193-6GC00-0NN0 SIMATIC ET 200SP HA, carrier module 8-fold carrier for holding 8 I/O modules of the ET 200SP HA.

Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA

Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA, carrier module 2-fold carrier for holding 2 I/O modules of the ET 200SP HA.

Assortments

Description

Yokogawa RTD Input Module AAR181-S00 

  

   STANDARD SPECIFICATIONS of  AAR181-S00

      TC/RTD Input Modules (Isolated) 

     AAR181A, AAT141 These modules receive signals from mV, thermocouple (TC), and RTD. They can be used in dual-redundant 

      

     

ItemsSpecifications
ModelAAT141AAR181
Number of input channels16, isolated (*7)12, isolated
Input signalTC: JIS C1602:1995, IEC584:1995
Type J, K, E, B(*1), R, S, T, N
mV: -100 to 150 mV, -20 to 80 mV
RTD: JIS C1604:1997, IEC751:1995
Pt100 (3-wire type)(*6)
Switching input signalsTC/mV can be set individually for CH1 to CH16.CH1 to CH12 are RTD inputs.
Allowable input voltage±5 V±5 V
Withstanding voltageBetween input and system: 1500 V AC, for 1 minute
Input resistancePower ON 2 MΩ or larger
Power OFF 2 MΩ or larger
AccuracyTC: ±30 μV
MV: ±80 μV for span (-100 to 150 mV)
±30 μV for span (-20 to 80 mV)
RTD: ±120 mΩ
Allowable total resistance of
signal source plus wiring
1000 Ω or less40 Ω or less (wiring resistance per wire) (*2)
Effect of allowable signal source
resistance (1000 Ω)
±20 μV(*3)
Reference junction compensation
accuracy
Within ±1 °C (*4) (*5)
Measurement current
RTD: 1 mA
Temperature drift±80 μV/10 °C (-100 to 150 mV input)
±30 μV/10 °C (TC/-20 to 80 mV input
±120 mΩ/10 °C (RTD input)
Data update period1 s
Burn-outAll channels can be set together.
Setting: Not available/available (UP/DOWN)
Detection time: 60 s

Maximum current consumption450 mA (5 V DC)450 mA (5 V DC)
Weight0.2 kg

 

Yokogawa RTD Input Module AAR181-S00  

 

  

   EXTERNAL DIMENSIONS of  AAR181-S00 

 

 

     Yokogawa RTD Input Module AAR181-S00   

MODEL AND SUFFIX CODES  AAR181-S00



Description
ModelAAR181RTD Input Module (12-channel, Isolated)

-SStandard type
Suffix
Codes
   5With no explosion protection

   EWith explosion protection

      0Basic type

      3With ISA Standard G3 option and temperature (-20 to 70 °C) option
Option
Codes



/R8S00With Pressure Clamp Terminal Block for RTD [Model: ATR8S-00]

/R8S10With Pressure Clamp Terminal Block for RTD (surge absorber) [Model: ATR8S-10]

/R8D00With Dual Pressure Clamp Terminal Block for RTD [Model: ATR8D-00]

/R8D10With Dual Pressure Clamp Terminal Block for RTD (surge absorber) [Model: ATR8D-10]

/CCC01With Connector Cover for MIL Cable [Model: ACCC01

 

 

 

Yokogawa RTD Input Module AAR181-S00