Yokogawa EJA118E-JMSCJ-919DB-WA42C2SW00-AA23/KS21/D3 Diaphragm Sealed Pressure Transmitter-hkxytech
  • Yokogawa EJA118E-JMSCJ-919DB-WA42C2SW00-AA23/KS21/D3 Diaphragm Sealed Pressure Transmitter
  • Yokogawa EJA118E-JMSCJ-919DB-WA42C2SW00-AA23/KS21/D3 Diaphragm Sealed Pressure Transmitter
  • Yokogawa EJA118E-JMSCJ-919DB-WA42C2SW00-AA23/KS21/D3 Diaphragm Sealed Pressure Transmitter

Yokogawa EJA118E-JMSCJ-919DB-WA42C2SW00-AA23/KS21/D3 Diaphragm Sealed Pressure Transmitter

2019-05-13 16:33:44

Description:

Zero-based calibrated span, linear output……

Notice:

New Products

E+H e&h Endresss Hauser FMU30-AAHEABGHF Ultrasonic measurement Time-of-Flight Prosonic FMU30 are in stock

Field of application: Two-wire instrument for continuous non-contact level and flow measurement. Process connection: Thread Temperature: -20 to +60°C (-4 to +140°F) Pressure: +0.7 to +3bar (+10 to +44psi) Maximum measuring distance: Sensor 1½" for liquids 5m (16ft) and for bulk solids 2m (6.6ft), Sensor 2" for liquids 8m (26ft)and for bulk solids 3.5m (11ft) Blocking distance: Sensor 1½" 0.25m (0.8ft), Sensor 2" 0.35m (1.15ft) International explosion protection certificates

Endresss Hauser original Ultrasonic measurement Time-of-Flight Prosonic FMU90 with best price made in Germany FMU90-R11CA212AA3A

010 Approval: R Non-hazardous area 020 Application: 1 Level + pump control, alternating 030 Housing, Material: 1 Field mounting PC, IP66 NEMA4x 040 Operation: C Illuminated display + keypad 050 Power Supply: A 90-253VAC 060 Level Input: 1 1x sensor FDU9x/8x 070 Switch Output: 1 1x relay, SPDT 080 Output: 1 1x 0/4-20mA HART 090 Additional Input: A W/o 100 Datalog Function: A Basic version 110 Language: 3 EN, ZH, JA, KO, TH, ID 120 Additional Option: A Basic version

Endress Hauser 7F2C15-AAACCAABBAAACSKA1 Proline Prowirl F 200 Vortex flowmeter 7F2C15

Same accuracy down to Re 10000 –most linear Vortex meter body

Endress Hauser FMU30-AAHEAAGGF Ultrasonic Level Measurement Transmitter FMU30-AAHEAAGGF

Envelope curves on the on-site display for simple diagnosis

Assortments

Description

Yokogawa EJA118E-JMSCJ-919DB-WA42C2SW00-AA23/KS21/D3 Diaphragm Sealed Differential Pressure Transmitter

 

Span and range limits of Yokogawa EJA118E-JMSCJ-919DB-WA42C2SW00-AA23/KS21/D3 Diaphragm Sealed Differential Pressure Transmitter

Yokogawa EJA118E-JMSCJ-919DB-WA42C2SW00-AA23KS21D3 (4)_副本.jpg

 

Measurement Span/Range

kPa

inH2O

(/D1)

mbar

(/D3)

mmH2O

(/D4)

M

Span

2.5 to 100

10 to 400

25 to 1000

250-10000

Range

-100 to 100

-400 to 400

-1000 to 1000

-10000 to 10000

H

Span

25 to 500

100 to 2000

250 to 5000

0.25 to 5 kgf/cm2

Range

-500 to 500

-2000 to 2000

-5000 to 5000

-5 to 5 kgf/cm2

 

Performance specifications of Yokogawa EJA118E-JMSCJ-919DB-WA42C2SW00-AA23/KS21/D3 Diaphragm Sealed Differential Pressure Transmitter

 Yokogawa EJA118E-JMSCJ-919DB-WA42C2SW00-AA23KS21D3 (5)_副本.jpg

Zero-based calibrated span, linear output, wetted parts material code SW for 3-inch flange flush type, fill fluid code B, and capillary length of 5 m. For Fieldbus and PROFIBUS communication types, use caribrated range instead of span in the following specifications.

 

Functional specifications of Yokogawa EJA118E-JMSCJ-919DB-WA42C2SW00-AA23/KS21/D3 Diaphragm Sealed Differential Pressure Transmitter

 

Output “◊”For 4 to 20 mA HART / BRAIN (Output signal code D and J) Two wire 4 to 20 mA DC output with digital communications, linear or square root programmable. BRAIN or HART FSK protocol are superimposed on the 4 to 20 mA signal. Output range: 3.6 mA to 21.6 mA Output limits conform to NAMUR NE43 can be preset by option code C2 or C3.

 

Similar model codes of Yokogawa EJA118E-JMSCJ-919DB-WA42C2SW00-AA23/KS21/D3 Diaphragm Sealed Differential Pressure Transmitter for your reference :

 

EJA118E-JMSCJ-919DB-WA42C2SW00-AA23/KS21/D3, EJA118E-JMSCJ-919DB-WA42C2SW00-AA27/KS21/D3, EJA118E-JHSCC-919EB-WA22C1SW00-AA22/KS21, EJA118E-FHSCG-919DJ-WA23C2HW00-AA25/KS26, EJA118E-FHSCC-919DJ-WA23C2HW00-AA25/KS26, EJA118E-JHSCG-919DB-WA13C2SW00-AA22/D4/KF22, EJA118E-JHSCG-919DB-WA13C2SW00-AA25/D3/KF22, EJA118E‐JMSCJ‐914EB‐WA22C2, EJA118E-DMSCG-91DDB, EJA118E-DMSCJ-917EA-WA12A1SW00-BA22/NS21, EJA118E-JMSCJ-912DA-WA12A2SW00, EJA118E-JMSCJ-939DA-WA43C1SW00-AA25, EJA118E-JMSCJ-917DA-WA22B1SW00-BA21NS21, EJA118E-JMSCJ-91CEB-WA22B2S, EJA118E-JMSCJ-912DA-WH22A2SW00-A

Yokogawa EJA118E-JMSCJ-919DB-WA42C2SW00-AA23KS21D3 (6)_副本.jpg

 

If you have any question, please do not hesitate to contact with me online

Contact details :

Shirley Sun

Sales Engineer

HONGKONG XIEYUAN TECH CO., LIMITED

Add : 7-A16, Caishen Commercial Plaza, Hankou Railway Station, Wuhan, China

M : +86-15172506760 (WhatsApp & Wechat) | T : +86-27-85802699  | F : +86-27-85309780

Email : Shirley@whxyauto.com     Skype : 169649423@qq.com