Top Industrial Automation and Electrical Instrument from HKXYTECH
  • Rosemount 3051CFADG120ZCHPS2T100031AA1I1M5HR5 Annubar Flow Meter Emerson Measurement Instrumentation

Rosemount 3051CFADG120ZCHPS2T100031AA1I1M5HR5 Annubar Flow Meter Emerson Measurement Instrumentation

2018-07-27 11:20:37

Description:

An industry-leading flow measurement solution, the Rosemount 3051CFA Annubar Flow Meter is customized with a patented T-shaped, averaging pitot tube that features reliable accuracy over a wide flow range. ……

New Products

Siemens 6DL1193-6TP00-0DH1 SIMATIC ET 200SP HA

Siemens 6DL1193-6TP00-0DH1 SIMATIC ET 200SP HA, Terminal block, Type H1, 32 push-in terminals, internal reference temperature New load group, width: 22.5 mm.

Siemens 6DL1193-6TP00-0BH1 SIMATIC ET 200SP HA

Siemens 6DL1193-6TP00-0BH1 SIMATIC ET 200SP HA, Terminal block, Type H1, 32 push-in terminals, internal reference temperature Width: 22.5 mm.

Siemens 6DL1193-6GC00-0NN0 SIMATIC ET 200SP HA

Siemens 6DL1193-6GC00-0NN0 SIMATIC ET 200SP HA, carrier module 8-fold carrier for holding 8 I/O modules of the ET 200SP HA.

Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA

Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA, carrier module 2-fold carrier for holding 2 I/O modules of the ET 200SP HA.

Assortments

Description

Rosemount 3051CFADG120ZCHPS2T100031AA1I1M5HR5 Annubar Flow Meter Emerson Measurement Instrumentation Flow

 

An industry-leading flow measurement solution, the Rosemount 3051CFA Annubar Flow Meter is customized with a patented T-shaped, averaging pitot tube that features reliable accuracy over a wide flow range. This patented sensor design maintains a small profile in the pipe for reduced permanent pressure loss and is capable of flow and pressure measurements via a single pipe penetration. This flow meter is also leak-tested and calibrated to reduce leak points for increased process control.

 

Specifications

Warranty Up to 5-year limited warranty

Rangedown Up to 150:1 (8:1 flow turndown)

Measurement Range Up to 1000 inH2O (2,48 bar) differential

Line Size 2 to 96 in. (50 to 2440 mm)

Output Differential pressure, scaled variable

Communication Protocol 4-20 mA HART®, WirelessHART®, FOUNDATION™ Fieldbus, PROFIBUS®, 1-5 V Low Power HART®

Process Wetted Material 316L SST, Alloy C-276

Diagnostics Power Advisory Diagnostics, basic diagnostics

Certifications/Approvals SIL 2/3 certified to IEC 61508 by an independent 3rd party, NACE®, hazardous location, see full specs for complete list of certifications

 

Features

Patented T-shape Annubar creates a fixed separation point for DP signal improvement over a wider flow rate

Complete flow assemblies are leak-tested and calibrated to reduce leak points up to 70% and simplify installation

10-year stability and 8:1 flow turndown (150:1 rangedown) produce reliable measurements and application flexibility

Sensor stagnation zone positioned to reduce noise, measurement inaccuracies and keeps particulates from clogging

Local operator interface offers easy-to-use menus and built-in configuration buttons for streamlined commissioning

Power advisory diagnostics detect electrical loop integrity issues for reduced downtime

SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations

 

Similar model codes for your reference :

3051CFADG025ZC

3051CFADG180ZCHP

3051CFADG080DSHPS2T100031AA1M5

3051CFADG025DSHPS1T100031AA1M5

3051CFADG160ZCHPS2T100032AA1I1M5

3051CFADG300ZCHPS2T100031AA1I1M5

3051CFADG180ZCHPS2T100031AA1KSM5

3051CFADG120ZCHPS2T100031AA1I1M5HR5

 

If you have any question, please do not hesitate to contact with me online

Contact details :

Shirley Sun

Sales Engineer

HONGKONG XIEYUAN TECH CO., LIMITED

Add : 7-A16, Caishen Commercial Plaza, Hangkou Railway Station, Wuhan, China

M : +86-15172506760 (WhatsApp & Wechat) | T : +86-27-85309780  | F : +86-27-85309780

Email : Shirley@whxyauto.com     Skype : 169649423@qq.com

Web : www.hkxytech.com