Bently Nevada Pressure Transducer Systems-hkxytech
  • Bently Nevada Pressure Transducer Systems
  • Bently Nevada Pressure Transducer Systems

Bently Nevada Pressure Transducer Systems

2016-06-30 14:51:54

Description:

GE Bently Nevada offers a very wide variety of pressure sensors or transmitters, each designed to handle the rigors of industrial environments and many capable of being installed in hazardous areas when appropriate I.S. barriers, galvanic isolation, or other means are used. ……

Notice:

New Products

Honeywell Analytics SPSTAXH1SS Sensepoint Flammable and Toxic Gas Detector Explosion-Proof Transmitters

Cost-effective, fixed point gas detector for the protection of personnel and plant from flammable, toxic and Oxygen gas hazards

Honeywell Analytics Sensepoint XCD RTD Remote toxic and oxygen gas detector for industrial applications

3 wire, 4-20mA and RS485 MODBUS output fixed point detector with in-built alarm and fault relays for the protection of personnel and plant from toxic and oxygen hazards.

Honeywell Analytics Sensepoint XCD RFD Remote Flammable Gas Monitor Explosion-Proof Transmitters

3-wire, 4-20mA, transmitter with optional Modbus for use with remotely mounted flammable gas sensors 705 and 705HT

Assortments

Description

Bently Nevada Pressure Transducer Systems


GE Bently Nevada offers a very wide variety of pressure sensors or transmitters, each designed to handle the rigors of industrial environments and many capable of being installed in hazardous areas when appropriate I.S. barriers, galvanic isolation, or other means are used. 


Features and Benefits


The Cylinder Pressure System consists of the 165855 Cylinder Pressure Transducer and the 146824 Interconnect cable. It is intended for measuring the cyclic absolute pressure changes inside a reciprocating compressor cylinder. This transducer is an integral part of a Reciprocating Compressor Condition Monitoring and Asset Management System when utilized with our 3500/77M Cylinder Pressure Monitor and System 1* Plant Asset Management Software.

The Cylinder Pressure Transducer has a robust design for high reliability in harsh chemical environments.

The unique, patent-pending design also allows the transducer to continue to provide an accurate pressure reading, even after being continually cycled over large pressure gradients for an extended period of time.

The transducer can also withstand over-pressure situations caused by application upsets without diaphragm degradation, returning to normal operation when the operating pressure returns to the transducer’s specified operating pressure range.

The Cylinder Pressure Transducer is also designed to meet NEMA 4X and IP67 conditions for moisture ingression.


The 350500 Dynamic Pressure Charge Amplifier (DPCA) is a component in a dynamic pressure sensing system. This sensing system, which monitors pressure pulsations that result from combustion instability in gas turbine engines, consists of a charge-coupled piezoelectric pressure sensor, low noise interconnect cable, 350500 charge amplifier, and monitoring device.

The dynamic pressure sensor should be a high-temperature piezoelectric type that converts dynamic pressure to an output signal scaled in pico-coulombs per unit of pressure.

The 350500 charge amplifier design allows its use with a number of sensors designed to monitor combustion instability.

 

The Dual Pressure flexiTIM* module interfaces 2 individual pressure transducers to the Trendmaster* 2000 System and is intended for non-dynamic pressure applications.

The flexiTIM module and cable interfaces with pressure transducers using a 4-pin, locking bayonet connection. Compatible transducers are standard, millivolt output type devices with an output sensitivity of 10 mV/V.

This flexibility allows the dual pressure flexiTIM system to measure a wide range of pressures under a variety of operating conditions. We offer a standard transducer for use with the flexiTIM module for convenience.