Description:

Dissolved oxygen (DO) is a liquid process measurement for determining the amount of oxygen dissolved or carried in the process liquid. There are three common technologies for dissolved oxygen measurements: polographic, galvanic and optical. The standard units of measure are milligrams per liter (mg/l), parts per million (ppm), parts per billion (ppb), or % saturation.……

New Products

HCD2-FBPS-1.500 Fieldbus Power Supply - Pepperl+Fuchs

HCD2-FBPS-1.500 Fieldbus Power Supply, module for fieldbus power hub. This Power Supply Module is a system component for the FieldConnex®Power Hub and can be plugged into the motherboard.

HiC2025 SMART Transmitter Power Supply - Pepperl+Fuchs

Pepperl+Fuchs HiC2025 is a SMART transmitter power supply designed for analog input, boasting a Safety Integrity Level (SIL) of 2 and a Systematic Capability (SC) of 3.

HiC2031 SMART Current Driver - Pepperl+Fuchs

Pepperl+Fuchs HiC2031 is a SMART Current Driver featuring analog output. This isolated barrier is used for intrinsic safety applications.

OMRON 3G3MX2-AB022-V2 inverter drive

OMRON 3G3MX2-AB022-V2 MX2-EV2 inverter drive, 2.2/3.0 kW (ND/LD), 11.0/12.0 A (ND/LD), 200 VAC, 1~ input, sensorless vector, max. output freq. 590Hz

Assortments

Description

DO70G

DO70G optical dissolved oxygen sensor is designed for using in water treatment plants such as sewage treatment works and effluent activated sludge process.

This optical sensor has a fast response time and good long term stability, and features replaceable sensor cap and cable for easy maintenance. A temperature sensor is incorporated for compensation. The DO70G sensor can be used in either the PB350G/PB360G floating ball holder or in the DOX8HS submersion type holder.

  • A Optical DO sensor that uses a phase measurement method and realizing stable measurements over a long period of time.

  • Measuring range of 0 to 25 mg/l.

  • A sensor cap that is easily replaceable by anyone.

Dissolved Oxygen0 to 25 mg/l (ppm)
Liquid Temperature0 to 50℃
Liquid Pressure0 to 500 kPa
Flow speed20 cm/s or more
Sensor for Temperature Compensation22k NTC
Cable Length3, 5, 10 m
WeightSensor; Approx. 0.1 kg
Cable; 3 m; Approx. 0.4 kg / 5 m; Approx. 0.6 kg / 10 m; Approx. 1.1 kg
Repeatability0.1 mg/l or 3% FS, whichever is greater
Temperature Compensation ErrorWithin ±3% FS for a ±5℃ change in the range of 0 to 40℃
Response TimeWithin 120 sec. (90 % response)