Differential pH/ORP SC24V
2016-05-26 16:56:58
Description:
Sterilizable pH sensor No reference electrode or junction Low maintenance No diffusion = high stability Applications Process where KCL is forbidden Process with rapid temperature / pressure changes Chlorine manufacturing (electrolysis of Brine) Bio-ethanol fermentation processes Pulp and Paper……
New Products
FXT1-P37 Right Angle Milling Head
FXT1-P37 Right Angle Milling Head - HKXYTECH
FXT1-P24 Right Angle Milling Head
FXT1-P24 Right Angle Milling Head - HKXYTECH
FXT1-P18 Right Angle Milling Head
FXT1-P18 Right Angle Milling Head - HKXYTECH
FXT1-AC Fully Automatic Right Angle Milling Heads
FXT1-AC Fully Automatic Right Angle Milling Heads - HKXYTECH
Assortments
▶ Pressure Transmitter EJA
▶ Pressure Transmitters EJA-E
▶ Pressue Transmitter EJX
▶ Safety Instrumented System (SIS)
▶ Valve Positioners & Converters
▶ Field Mount Indicators
▶ Temperature Transmitters
▶ Magnetic Flowmeters
▶ Vortex Flowmeter
▶ Ultrasonic Flowmeters
▶ Coriolis Mass Flowmeters - ROTAMASS 3-Series
▶ Variable Area Flowmeters – Rotameters
▶ Device Smart Communicators
▶ PORTABLE AND HANDHELD INSTRUMENTS
▶ Distributed Control System (DCS)
▶ Process Analyzers
▶ Paperless Recorders
▶ Strip Chart Recorders
▶ Data Acquisition Equipment
▶ UT Series Temperature Controllers
▶ UP Series Program Controllers
▶ UM Series Digital Indicators with Alarms
▶ UT100 Series Temperature Controllers
▶ UD Series Manual Setters
▶ Limit Controllers
▶ YS Series Single-loop Controllers
Description
Differential pH/ORP SC24V
The SC24V differential pH/ORP sensor is unique to the industry, offering maintenance free operation without any reference problems. In the SC24V differential pH/ORP sensor, the reference cell is made of glass, with no porous junction, so no electrolyte is in contact with the process.
The differential measuring principle combines the normal potential generated by the pH glass with the potential from a Sodium pNa glass. In applications where Sodium-, Potasium- or Calcium-salt is present the glass will generate a stable reference voltage. This means the measurement can be done, eliminating problems caused by aging and pollution of the liquid junction. Experienced with a conventional reference electrodes.
Features
Sterilizable pH sensor
No reference electrode or junction
Low maintenance
No diffusion = high stability Applications
Process where KCL is forbidden
Process with rapid temperature / pressure changes
Chlorine manufacturing (electrolysis of Brine)
Bio-ethanol fermentation processes
Pulp and Paper