Dust Monitor DT450G
2016-05-26 15:56:41
Description:
Air pollution control systems such as bag filters and electrostatic precipitators are used to separate particulate or dust from the gas stream before it is exhausted into the atmosphere. To maintain the dust concentration of the emission gas below the specified level through effective operation of the control system, it is essential to continuously monitor the dust concentration of the exhaust gas. Based on installation and application experiences with the old model DT400G, the microprocessor-based DT450G Dust Monitor features improved operationality and reliability. Features include one-touch automatic range setup in response to process conditions and automatic drift compensation. Also, the DT450G can measure at a process temperature of up to 250℃, allowing it to cover a wide range of applications.……
New Products
Honeywell 51307038-100 Power Control Module Assy
Honeywell 51307038-100 Power Control Module Assy. Honeywell Experion LX Series 8 C300 controller provides powerful and robust control for the Experion LX platform.
Honeywell 8937-HN2 Fibre Optic converter IO Module
Honeywell 8937-HN2 Multi-Mode, Fibre Optic converter IO Module. The Fiber Option Extender modules support the extension of the I/O link beyond the Series 8 cabinet with the S8 C300, enabling remote applications of the Series 8 I/O.
Honeywell 8939-HN Multi-Mode Fiber Optic Extender (IOTA)
Honeywell 8939-HN Multi-Mode Fiber Optic Extender IOTA. The Fiber Option Extender modules support the extension of the I/O link beyond the Series 8 cabinet with the S8 C300, enabling remote applications of the Series 8 I/O.
G.M. International X1-IS-AO-02-S I.S. SIL2 HART® Isolating Driver module
G.M. International X1-IS-AO-02-S I.S. SIL2 HART® Isolating Driver module. GMI Intrinsically Safe Isolators, Analog Output
Assortments
▶ Pressure Transmitter EJA
▶ Pressure Transmitters EJA-E
▶ Pressue Transmitter EJX
▶ Safety Instrumented System (SIS)
▶ Valve Positioners & Converters
▶ Field Mount Indicators
▶ Temperature Transmitters
▶ Magnetic Flowmeters
▶ Vortex Flowmeter
▶ Ultrasonic Flowmeters
▶ Coriolis Mass Flowmeters - ROTAMASS 3-Series
▶ Variable Area Flowmeters – Rotameters
▶ Device Smart Communicators
▶ PORTABLE AND HANDHELD INSTRUMENTS
▶ Distributed Control System (DCS)
▶ Process Analyzers
▶ Paperless Recorders
▶ Strip Chart Recorders
▶ Data Acquisition Equipment
▶ UT Series Temperature Controllers
▶ UP Series Program Controllers
▶ UM Series Digital Indicators with Alarms
▶ UT100 Series Temperature Controllers
▶ UD Series Manual Setters
▶ Limit Controllers
▶ YS Series Single-loop Controllers
Description
Dust Monitor DT450G
Air pollution control systems such as bag filters and electrostatic precipitators are used to separate particulate or dust from the gas stream before it is exhausted into the atmosphere. To maintain the dust concentration of the emission gas below the specified level through effective operation of the control system, it is essential to continuously monitor the dust concentration of the exhaust gas.
Based on installation and application experiences with the old model DT400G, the microprocessor-based DT450G Dust Monitor features improved operationality and reliability. Features include one-touch automatic range setup in response to process conditions and automatic drift compensation. Also, the DT450G can measure at a process temperature of up to 250℃, allowing it to cover a wide range of applications.
Drift compensation
Direct measurement at a process temperature of up to 250℃
One-touch, automatic setup of range appropriate for the process conditions
Inductive electrificaion; probe is stain resistant and requires minimal maintenance
Integrated design allows for easy installation
Maintenance-free operation for a long period
| Measurement range | 0.1 mg/m3 to 1 kg/m3 |
|---|---|
| Measurement principle | Inductive electrification |
| Sample gas conditions | Temperature :250℃ or less Pressure: 200 kPa or less Gas flow rate: 4 m/s or greater (approx. 30 m/s Max.) Humidity: 40 %RH or less |
| Setting measurement range | Range setup: One-touch automatic setup or manual setup Note: With one-touch automatic setup function, measurement range is set so that the dust concentration of the process corresponds to a setpoint of setting level. In manual setup, the measurement range is set by gain (x1, x10, x100, x1000, x10000). Setup range: Variable (10 to 50%, 10% step) |
| Analog output signal | 4 to 20 mA DC (isolated, load resistance of 500 Ω) |
| Contact output signal (high/low alarm) | 2 outputs |
| Ambient conditions | Temperature: -20 to 45℃ Humidity: 95% RH or less (non-condensing) Vibration: 5 m/S2 (0.5G) or less |
| Construction | Integrated sensor and converter Direct insertion type, rainproof (IP64) |
| Materials | Sensor probe: Stainless steel (316SS equivalent) Insulation of sensor: PEEK Case: Aluminum |
| Power supply | 100-120 V AC or 200-240 V AC, 50/60 Hz, 8VA |
| Air purge | Instrument air (dry air) Pressure: +50 kPa or greater (continuous) Air Connection: Rc 1/4 Air consumption; Approx. 50 Nl/min |
| Weight | Approx. 2.3 kg (excluding flange) |
| Dimensions | 172(W) x 173(H) x 672(D) mm |