Description:

Air pollution control systems such as bag filters and electrostatic precipitators are used to separate particulate or dust from the gas stream before it is exhausted into the atmosphere. To maintain the dust concentration of the emission gas below the specified level through effective operation of the control system, it is essential to continuously monitor the dust concentration of the exhaust gas. Based on installation and application experiences with the old model DT400G, the microprocessor-based DT450G Dust Monitor features improved operationality and reliability. Features include one-touch automatic range setup in response to process conditions and automatic drift compensation. Also, the DT450G can measure at a process temperature of up to 250℃, allowing it to cover a wide range of applications.……

Description

Dust Monitor DT450G

Air pollution control systems such as bag filters and electrostatic precipitators are used to separate particulate or dust from the gas stream before it is exhausted into the atmosphere. To maintain the dust concentration of the emission gas below the specified level through effective operation of the control system, it is essential to continuously monitor the dust concentration of the exhaust gas.

Based on installation and application experiences with the old model DT400G, the microprocessor-based DT450G Dust Monitor features improved operationality and reliability. Features include one-touch automatic range setup in response to process conditions and automatic drift compensation. Also, the DT450G can measure at a process temperature of up to 250℃, allowing it to cover a wide range of applications.


  • Drift compensation

  • Direct measurement at a process temperature of up to 250℃

  • One-touch, automatic setup of range appropriate for the process conditions

  • Inductive electrificaion; probe is stain resistant and requires minimal maintenance

  • Integrated design allows for easy installation

  • Maintenance-free operation for a long period

Measurement range0.1 mg/m3 to 1 kg/m3
Measurement principleInductive electrification
Sample gas conditions

Temperature :250℃ or less

Pressure: 200 kPa or less

Gas flow rate: 4 m/s or greater (approx. 30 m/s Max.)

Humidity: 40 %RH or less

Setting measurement rangeRange setup: One-touch automatic setup or manual setup Note: With one-touch automatic setup function, measurement range is set so that the dust concentration of the process corresponds to a setpoint of setting level. In manual setup, the measurement range is set by gain (x1, x10, x100, x1000, x10000). Setup range: Variable (10 to 50%, 10% step)
Analog output signal4 to 20 mA DC (isolated, load resistance of 500 Ω)
Contact output signal (high/low alarm)2 outputs
Ambient conditions

Temperature: -20 to 45℃

Humidity: 95% RH or less (non-condensing)

Vibration: 5 m/S2 (0.5G) or less

ConstructionIntegrated sensor and converter Direct insertion type, rainproof (IP64)
Materials

Sensor probe: Stainless steel (316SS equivalent)

Insulation of sensor: PEEK

Case: Aluminum

Power supply100-120 V AC or 200-240 V AC, 50/60 Hz, 8VA
Air purge

Instrument air (dry air) Pressure: +50 kPa or greater (continuous)

Air Connection: Rc 1/4

Air consumption; Approx. 50 Nl/min

WeightApprox. 2.3 kg (excluding flange)
Dimensions172(W) x 173(H) x 672(D) mm