OX102
2016-05-26 15:23:09
Description:
The OX102 Oxygen Analyzer measures oxygen concentration from ppm to percent levels in a single analyzer and is ideal for ppm-level measurements in applications such as nitrogen reflow furnaces and semiconductor plants. The zirconia oxygen sensor uses a method that is based on the limiting current principle and is compact, yet has high-performance. The sensor is designed for installation by direct insertion When a sample gas contains organic solvent at a few ppm to percent level in applications such as nitrogen reflow furnaces, an optional sampling unit is required.……
New Products
Orbinox VG SERIES 61 Slurry knife gate valve
Orbinox SERIES 61 (VG) model knife gate valve is a wafer type valve equipped with two metal reinforced rubber sleeves,designed for applications with abrasive slurries.
Crosby J-Series Direct Spring Pressure Relief Valves
J-Series valves provide high quality and dependable overpressure protection for air, gas, steam, vapor, liquid and two-phase applications in one simple design. Now available with two new to the world technologies, Balanced Diaphragm and Bellows Leak Detection.
Vanessa Series 30,000 Cryogenic Triple Offset Valve
The Vanessa Series 30,000 Cryogenic Triple Offset Valve is a virtually maintenance-free valve with tightness, operability and torque demand unaffected by cryogenic conditions and severe temperature fluctuations.
Sempell Model SOT High pressure steam safety valve
The Sempell Model SOT is a high-pressure steam safety valve designed for boiler protection and steam system safety.
Assortments
▶ Pressure Transmitter EJA
▶ Pressure Transmitters EJA-E
▶ Pressue Transmitter EJX
▶ Safety Instrumented System (SIS)
▶ Valve Positioners & Converters
▶ Field Mount Indicators
▶ Temperature Transmitters
▶ Magnetic Flowmeters
▶ Vortex Flowmeter
▶ Ultrasonic Flowmeters
▶ Coriolis Mass Flowmeters - ROTAMASS 3-Series
▶ Variable Area Flowmeters – Rotameters
▶ Device Smart Communicators
▶ PORTABLE AND HANDHELD INSTRUMENTS
▶ Distributed Control System (DCS)
▶ Process Analyzers
▶ Paperless Recorders
▶ Strip Chart Recorders
▶ Data Acquisition Equipment
▶ UT Series Temperature Controllers
▶ UP Series Program Controllers
▶ UM Series Digital Indicators with Alarms
▶ UT100 Series Temperature Controllers
▶ UD Series Manual Setters
▶ Limit Controllers
▶ YS Series Single-loop Controllers
Description
OX102
The OX102 Oxygen Analyzer measures oxygen concentration from ppm to percent levels in a single analyzer and is ideal for ppm-level measurements in applications such as nitrogen reflow furnaces and semiconductor plants.
The zirconia oxygen sensor uses a method that is based on the limiting current principle and is compact, yet has high-performance. The sensor is designed for installation by direct insertion
When a sample gas contains organic solvent at a few ppm to percent level in applications such as nitrogen reflow furnaces, an optional sampling unit is required.
One instrument capable of measuring from 0 - 100 ppm to 0 - 25% oxygen
Simple one touch calibration
Self diagnostics assure high reliability
One touch sensor replacement
Compact size
Applications
N2 reflow furnaces
Semiconductor maker environmental monitoring
ppm-level O2 measurement
Monitoring purity of N2, Ar separated from air
Monitoring for deficiency of O2
Measured gas | O2 in N2 or mixed gases; cannot be used with silicone vapor, combustible gases and organic solvents |
Measurement principle | Zirconia limiting current method |
Measuring range | 0 - 100 ppm/0 - 1000 ppm/0 - 10000 ppm/0 - 25%, automatic/fixed switching mode |
Sampling method | Natural diffusion system. If the sampled gas may include organic solvents, use a sampling unit. |
Sample gas conditions | Temperature; 0 to 70℃ Humidity; 0 to 80%RH Pressure; 1013±40 hPa(Abs) |
Output signal | 1. 4-20 mA DC isolated, fixed range(0 - 100, 0 - 1000, 0 - 1000 ppm, 0 - 25% selectable), or 4 - 20 mA DC autoranging 2. 1 to 5 V DC fixed range(0-100, 0-1000, 0-10000 ppm, 0-25% selectable) 3. Zone signal output for 4 - 20 mA DC autoranging |
Contact output | 2 outputs |
Alarm output | High or Low alarm |
Calibration | a. Atmospheric air one-point calibration : 15 to 25% O2 range b. One-point calibration at 100 ppm : 80 to 120 ppm O2 range c. One-point calibration at 1000 ppm : 900 to 1100 ppm O2 range d. One-point calibration at 10000 ppm : 8500 to 9500 ppm O2 range e. Complete calibration : with air, 20, 100, 500, 1000, 10000 ppm in that order |
Extension cable | 4 m, 9 m, 29 m |
Power supply | 100 to 240 V AC, 50/60 Hz, approx. 15 W |
Converter size | 96(W) x 96(H) x 190(D) mm |