OX102
2016-05-26 15:23:09
Description:
The OX102 Oxygen Analyzer measures oxygen concentration from ppm to percent levels in a single analyzer and is ideal for ppm-level measurements in applications such as nitrogen reflow furnaces and semiconductor plants. The zirconia oxygen sensor uses a method that is based on the limiting current principle and is compact, yet has high-performance. The sensor is designed for installation by direct insertion When a sample gas contains organic solvent at a few ppm to percent level in applications such as nitrogen reflow furnaces, an optional sampling unit is required.……
New Products
FXT1-P37 Right Angle Milling Head
FXT1-P37 Right Angle Milling Head - HKXYTECH
FXT1-P24 Right Angle Milling Head
FXT1-P24 Right Angle Milling Head - HKXYTECH
FXT1-P18 Right Angle Milling Head
FXT1-P18 Right Angle Milling Head - HKXYTECH
FXT1-AC Fully Automatic Right Angle Milling Heads
FXT1-AC Fully Automatic Right Angle Milling Heads - HKXYTECH
Assortments
▶ Pressure Transmitter EJA
▶ Pressure Transmitters EJA-E
▶ Pressue Transmitter EJX
▶ Safety Instrumented System (SIS)
▶ Valve Positioners & Converters
▶ Field Mount Indicators
▶ Temperature Transmitters
▶ Magnetic Flowmeters
▶ Vortex Flowmeter
▶ Ultrasonic Flowmeters
▶ Coriolis Mass Flowmeters - ROTAMASS 3-Series
▶ Variable Area Flowmeters – Rotameters
▶ Device Smart Communicators
▶ PORTABLE AND HANDHELD INSTRUMENTS
▶ Distributed Control System (DCS)
▶ Process Analyzers
▶ Paperless Recorders
▶ Strip Chart Recorders
▶ Data Acquisition Equipment
▶ UT Series Temperature Controllers
▶ UP Series Program Controllers
▶ UM Series Digital Indicators with Alarms
▶ UT100 Series Temperature Controllers
▶ UD Series Manual Setters
▶ Limit Controllers
▶ YS Series Single-loop Controllers
Description
OX102
The OX102 Oxygen Analyzer measures oxygen concentration from ppm to percent levels in a single analyzer and is ideal for ppm-level measurements in applications such as nitrogen reflow furnaces and semiconductor plants.
The zirconia oxygen sensor uses a method that is based on the limiting current principle and is compact, yet has high-performance. The sensor is designed for installation by direct insertion
When a sample gas contains organic solvent at a few ppm to percent level in applications such as nitrogen reflow furnaces, an optional sampling unit is required.
One instrument capable of measuring from 0 - 100 ppm to 0 - 25% oxygen
Simple one touch calibration
Self diagnostics assure high reliability
One touch sensor replacement
Compact size
Applications
N2 reflow furnaces
Semiconductor maker environmental monitoring
ppm-level O2 measurement
Monitoring purity of N2, Ar separated from air
Monitoring for deficiency of O2
Measured gas | O2 in N2 or mixed gases; cannot be used with silicone vapor, combustible gases and organic solvents |
Measurement principle | Zirconia limiting current method |
Measuring range | 0 - 100 ppm/0 - 1000 ppm/0 - 10000 ppm/0 - 25%, automatic/fixed switching mode |
Sampling method | Natural diffusion system. If the sampled gas may include organic solvents, use a sampling unit. |
Sample gas conditions | Temperature; 0 to 70℃ Humidity; 0 to 80%RH Pressure; 1013±40 hPa(Abs) |
Output signal | 1. 4-20 mA DC isolated, fixed range(0 - 100, 0 - 1000, 0 - 1000 ppm, 0 - 25% selectable), or 4 - 20 mA DC autoranging 2. 1 to 5 V DC fixed range(0-100, 0-1000, 0-10000 ppm, 0-25% selectable) 3. Zone signal output for 4 - 20 mA DC autoranging |
Contact output | 2 outputs |
Alarm output | High or Low alarm |
Calibration | a. Atmospheric air one-point calibration : 15 to 25% O2 range b. One-point calibration at 100 ppm : 80 to 120 ppm O2 range c. One-point calibration at 1000 ppm : 900 to 1100 ppm O2 range d. One-point calibration at 10000 ppm : 8500 to 9500 ppm O2 range e. Complete calibration : with air, 20, 100, 500, 1000, 10000 ppm in that order |
Extension cable | 4 m, 9 m, 29 m |
Power supply | 100 to 240 V AC, 50/60 Hz, approx. 15 W |
Converter size | 96(W) x 96(H) x 190(D) mm |