Pepperl+Fuchs Termination Boards Special Termination Boards for Yokogawa Prosafe RS
2015-11-17 15:59:51
Description:
Intrinsically Safe (IS) Termination Boards Pepperl+Fuchs offers systems for different applications and mountings. Please have a look at our H-System and K-System Termination Boards recommended for Yokogawa Safety System.……
New Products
FXT1-P37 Right Angle Milling Head
FXT1-P37 Right Angle Milling Head - HKXYTECH
FXT1-P24 Right Angle Milling Head
FXT1-P24 Right Angle Milling Head - HKXYTECH
FXT1-P18 Right Angle Milling Head
FXT1-P18 Right Angle Milling Head - HKXYTECH
FXT1-AC Fully Automatic Right Angle Milling Heads
FXT1-AC Fully Automatic Right Angle Milling Heads - HKXYTECH
Assortments
Description
Termination Boards
Special Termination Boards for Yokogawa Prosafe RS
Pepperl+Fuchs provides Intrinsically Safe (IS) and Non Intrinsically Safe (NIS) Termination Boards recommended for Yokogawa Safety System.
Intrinsically Safe (IS) Termination Boards
Pepperl+Fuchs offers systems for different applications and mountings. Please have a look at our H-System and K-System Termination Boards
recommended for Yokogawa Safety System.
H-System Termination Boards
We are always pleased to improve our common solutions!
These Termination Boards are under development.
Please use our recommended standard Termination Boards;
Specific project related developments on request!
Yokogawa IO Card Adaptable Pepperl+Fuchs Product Product Data
Analog input
SAV144 MB-RS-AI16V-KS-185840
8 plug-in positions, Recommended module KFD2-STC4-Ex2, 24VDC supply voltage, Hazardous area: cage clamp blue terminals, Safe area
Yokogawa system connector for KS1
SAV144 MB-RS-S-AI16V-KS-192312
16 plug-in positions. Recommended module KFD2-STC4-Ex1. 24VDC supply voltage. Hazardous area: cage clamp blue terminals. Safe area
Yokogawa system connector for KS1
SAI143 MB-RS-AI16-KS-185838
8 plug-in positions, Recommended module KFD2-STC4-Ex2, 24VDC supply voltage, Hazardous area: cage clamp blue terminals, Safe area
Yokogawa system connector for KS1
SAI143 MB-RS-S-RTD16-KS-192299
16 plug-in positions. Recommended module KFD0-TR-Ex1, 24VDC supply voltage, Hazardous area: cage clamp blue terminals, Safe area
Yokogawa system connector for KS1
SAI143 MB-RS-S-AI16-KS-192311
16 plug-in positions, Recommended module KFD2-STC4-Ex1, 24VDC supply voltage, Hazardous area: cage clamp blue terminals, Safe area
Yokogawa system connector for KS1
Analog output
SAI533 MB-RS-S-AO8-KS-192323
8 plug-in positions, Recommended module KFD2-SCD2-Ex1.LK, 24VDC supply voltage, redundant, Hazardous area: screw blue terminals, Safe
area Yokogawa system connector KS1
Digital input
SDV144 MB-RS-DI16-AKB-185842
8 plug-in positions, Recommended module KFD2-SOT-Ex2, 24VDC supply voltage, Hazardous area: screw blue terminals, Safe area Yokogawa
system connector AKB
SDV144 MB-RS-S-DI16-AKB-192319
16 plug-in positions, Recommended module KFD2-SOT2-Ex1.LB, 24VDC supply voltage, redundant, Hazardous area: screw blue terminals, Safe
area Yokogawa system connector AKB
SDV144 MB-RS-S-DI16-AKB-192325
16 plug-in positions, Recommended module KFD2-SH-Ex1.T.OP (SIL3), 24VDC supply voltage, Hazardous area: screw blue terminals, Safe area
Yokogawa system connector AKB
Digital output
SDV531 MB-RS-DO8-AKB-185844
8 plug-in positions, Recommended module KFD2-SL2-Ex1, 24VDC supply voltage, Hazardous area: screw blue terminals, Safe area Yokogawa
system connector AKB
SDV541 MB-RS-S-DO16-AKB-192321
suitable for 16 pcs. KF-modules, single canal DO KF-module, rated voltage 24 V DC nominal, redundant and fused, power fail monitoring,
signalling via potential, free relais contact, 2 pcs. system connector (type: AKB), multipole 50 pin, screw terminals for field wiring, 2,5mm² via
KF-module, label carrier as an option, recommended module KFD2-SL2-Ex1
Non Intrinsically Safe (NIS) Termination Boards
Yokogawa IO Card Adaptable Pepperl+Fuchs Product Product Data
Analog input
SAI143 TB-RS-AI16-KS-186102
2 terminals/ signal, Field area: Pressure clamp terminals, DCS area Yokogawa system connector for KS1
SAV144 TB-RS-AI16V-KS-183383
3 terminals/ signal (active/ passive transmitters), Each signal fused on board Field area: Pressure clamp terminals, DCS area Yokogawa system
connector for KS1
SAI143 TB-YRS-R2-AIC16FL-KS-SC-227110
supported field devices: 2- and 3-wire-sensors, active, voltage source, rated voltage 24 V DC nominal, fused, power fail monitoring, signalling
via potential free relais contact, 2 pcs. system connector redundant (type: YOKOGAWA), multipole 40-pin, screw terminals for field wiring,
2,5mm², dimensions (whd): 156x155x90mm
Analog output
SAI533 TB-RS-AO8-KS-205527
2 terminals /signal, Field area: Pressure clamp terminals, DCS area Yokogawa system connector for KS1
Digital input
SDV144 TB-RS-DI16-AKB-185847
3 terminals/ signal (contact/ proximity switch), 24VDC supply voltage, Field area: Pressure clamp terminals, DCS area Yokogawa system
connector for AKB
ADV144 TB-YRS-R2-DIX16FS-AK-SP-214386
supported field devices: 3-wire-sensor, potential free contact, active voltage source, rated voltage 24 V DC nominal, fused, power fail
monitoring, signalling via potential free relais contact, 2 pcs. system connector redundant (type: YOKOGAWA), multipole 50-pin, scrimp clamp
terminals for field wiring, 2,5mm², dimensions (whd): 214x126x90mm
Digital output
SDV531 TB-RS-DO8-AKB-185849
2 terminals /signal, 24VDC supply voltage, Field area: Pressure clamp terminals, DCS area Yokogawa system connector for AKB
SDV541 TB-RS-DO16-AKB-204061
2 terminals/ signal, 24VDC supply voltage, 16 channels, Field area: Pressure clamp terminals, DCS area Yokogawa system connector for AKB
SDV521 TB-YRS-R2-DO04FS-AK-SC-224747
supported field devices: lamps, valves, resistors, DO: 24VDC/2,0A per channel, Rated voltage 24 V DC nominal, redundant and fused, power
fail monitoring, signalling via potential free relais contact, 2 pcs. system connector redundant (type: AKB), multipole 50-pin, screw terminals
for field wiring, 2,5mm², dimensions (whd): 114x155x90mm