Top Industrial Automation and Electrical Instrument from HKXYTECH
  • Product Solutions for Yokogawa CS3000 by Pepperl+Fuchs
  • Product Solutions for Yokogawa CS3000 by Pepperl+Fuchs
  • Product Solutions for Yokogawa CS3000 by Pepperl+Fuchs

Product Solutions for Yokogawa CS3000 by Pepperl+Fuchs

2015-11-17 15:52:10

Description:

Control System Product Solutions for Yokogawa CS3000 by Pepperl+Fuchs Pepperl+Fuchs provides different Interface, Fieldbus and Remote I/O solutions for Yokogawa CS3000 Control System. Special Termination Boards for Yokogawa CS3000 Pepperl+Fuchs provides Intrinsically Safe (IS) and Non Intrinsically Safe (NIS) Termination Boards for Yokogawa CS3000 Control System. Intrinsically Safe (IS) Termination Boards……

New Products

FXT1-P37 Right Angle Milling Head

FXT1-P37 Right Angle Milling Head - HKXYTECH

FXT1-P24 Right Angle Milling Head

FXT1-P24 Right Angle Milling Head - HKXYTECH

FXT1-P18 Right Angle Milling Head

FXT1-P18 Right Angle Milling Head - HKXYTECH

FXT1-AC Fully Automatic Right Angle Milling Heads

FXT1-AC Fully Automatic Right Angle Milling Heads - HKXYTECH

Assortments

Description


Control System

Product Solutions for Yokogawa CS3000 by Pepperl+Fuchs

Pepperl+Fuchs provides different Interface, Fieldbus and Remote I/O solutions for Yokogawa CS3000 Control System.

Special Termination Boards for Yokogawa CS3000

Pepperl+Fuchs provides Intrinsically Safe (IS) and Non Intrinsically Safe (NIS) Termination Boards for Yokogawa CS3000 Control System.

Intrinsically Safe (IS) Termination Boards

Pepperl+Fuchs offers systems for different applications and mountings. Please have a look at our H-System and K-System Termination Boards 


recommended for Yokogawa CS3000 control system.

H-System Termination Boards


We are always pleased to improve our common solutions!

These Termination Boards are under development.

 

Please use our recommended standard Termination Boards;

Specific project related developments on request!

Analog input

AAI141, AAI143 MB-C3-AI16-KS-131961

16 plug-in positions, Recommended module KFD2-STC4-Ex1, 24VDC supply voltage, Hazardous area: cage clamp blue terminals, Safe area 


Yokogawa system connector for KS1

AAI141, AAI143 MB-C3-AI16-KS-131974

8 plug-in positions, Recommended module KFD2-STC4-Ex2, 24VDC supply voltage, Hazardous area: cage clamp blue terminals, Safe area 


Yokogawa system connector for KS1

AAI135, AAI835 MB-C3-AI8-KS1-132000

8 plug-in positions, Recommended module KFD2-STC4-Ex1, 24VDC supply voltage, Hazardous area: cage clamp blue terminals, Safe area 


Yokogawa system connector for KS1

AAV141 MB-C3-AI16V-KS-131963

suitable for 8 pcs. KF-modules, dual AI KF-module, rated voltage 24 V DC nominal, redundant and fused, power fail monitoring, signalling via 


potential, free relais contact, HART connector on board, 2 pcs. system connector (type: KS), multipole 40-pin, redundant, screw terminals for 


field wiring, 2,5mm² via KF-module, label carrier as an option, recommended module KFD2-STC4-Ex2

Analog output

AAI543 MB-C3-AO16-KS-185976

8 plug-in positions, Recommended module KFD2-SCD2-EX2-Y1, 24VDC supply voltage, Hazardous area: cage clamp blue terminals, Safe area 


Yokogawa system connector for KS1

Analog in-output

AAB841 MB-C3-AIO16V-KS-182635

16 plug-in positions, Recommended modules KFD2-SCD2-EX1-Y1 (AO), KFD2-STC4-Ex1 (AI), 24VDC supply voltage, Hazardous area: cage clamp 


blue terminals, Safe area Yokogawa system connector for KS1

AAB841 MB-C3-AIO16V-KS-182637

8 plug-in positions, Recommended modules KFD2-SCD2-EX2-Y1 (AO), KFD2-STC4-Ex2 (AI), 24VDC supply voltage, Hazardous area: cage clamp 


blue terminals, Safe area Yokogawa system connector for KS1

AAI841 MB-C3-AIO16-KS-188686

suitable for 8 pcs. KF-modules, dual canal AI+AO KF-module, rated voltage 24 V DC nominal, redundant and fused, power fail monitoring, 


signalling via potential, free relais contact, HART connector on board, 2 pcs. system connector (type: KS), multipole 40 pin, screw terminals for 


field wiring, 2,5mm² via KF-module, label carrier as an option, recommended modules KFD2-STC4-EX2, KFD2-SCD2-Ex2.LK

Digital input

ADV151 MB-C3-DI32-AKB-131969

16 plug-in positions, Recommended module KFD2-SOT-Ex2, 24VDC supply voltage, Hazardous area: screw blue terminals, Safe area Yokogawa 


system connector AKB

Digital output

ADV551 MB-C3-DO32-AKB-131972

16 plug-in positions, Recommended module KFD2-SL2-Ex2, 24VDC supply voltage, Hazardous area: screw blue terminals, Safe area Yokogawa 


system connector AKB

ADV551, ADV561 MB-C3-DO32R-AKB-131949

32 plug-in positions, Recommended module KFD2-SL2-Ex1.B, 24VDC supply voltage, Hazardous area: screw blue terminals, Safe area 


Yokogawa system connector AKB



Yokogawa IO Card Adaptable Pepperl+Fuchs Product Product Data

Analog input

AAI141, AAI143 TB-C3-AI16-KS-Y192298

3 terminals/ signal (active/ passive transmitters), 24VDC supply voltage, Field area: Pressure clamp terminals, DCS area Yokogawa system 


connector for KS1

AAI135, AAP135 TB-C3-AI8-KS-188691

2 pcs. system connector redundant (type: KS), multipole, 40-pin, pressure clamp terminals for field wiring, dimensions (whd): 108x126x67mm

Analog output

AAI141, AAI143, AAI835, AAI841, AAB841, AAV144 TB-C3-AO16-KS-Y188684

2 terminals/ signal, Selection AI/AO through switch on board, 24VDC supply voltage, Field area: Pressure clamp terminals, DCS area Yokogawa 


system connector for KS1

Analog in-output

AAB841 TB-C3-AIO16V-KS1-182615

3 terminals/ signal for AI, 16 channels, 24VDC supply voltage, redundant, Field area: screw terminals, HART communication, DCS area 


Yokogawa system connector for KS1

AAI835 TB-C3-AIO8-KS-Y188685

3 terminals /signal (active/passive transmitters) for AI. AI & AO terminals separated. 24VDC supply voltage. Field area: Pressure clamp 


terminals. DCS area Yokogawa system connector for KS1

Digital input

ADV151, ADV161 TB-C3-DI32-AKB-Y188683

3 terminals/ signal for DI, 32 channels, 24VDC supply voltage, redundant, Field area: pressure clamp terminals, DCS area Yokogawa system 


connector for AKB

Digital output

ADV551, ADV561 TB-C3-DO32-AKB-Y188682

1 relay/ signal (32) NO contact, 24VDC supply voltage, Field area: Screw terminals, DCS area Yokogawa system connector for AKB

Others

AAR145 TB-UNI-AKB-188667

2 pcs. system connector redundant (type: AKB), multipole, 50-pin, 52 pcs. screw terminal, dimensions (whd): 140x126x67mm


Pepperl+Fuchs Interface Modules for Yokogawa CS3000

H-System Isolated Barriers

H-System Isolated Barriers Pepperl+Fuchs offers systems for different applications and mountings. Please have a look at our H-System and K-


System Isolated Barriers recommended for Yokogawa CS3000 control system.

KFD2-STC4-EX1 SMART Transmitter Power Supply, 1-channel isolated barrier, 24 V DC supply (Power Rail), 2-wire SMART transmitters or 


current sources, Output 4 mA ... 20 mA, Terminals with test points, Up to SIL2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 20 ... 


35 V DC, SIL/IEC 61508, Output signal: 0/4 ... 20 mA (overload > 25 mA), HART transfer, Input, current source, Explosion protection: Ex input


detail

KFD2-STC4-EX1.2O SMART Transmitter Power Supply, 1-channel isolated barrier, 24 V DC supply (Power Rail), 2-wire SMART transmitters or 


current sources, Dual output 4 mA ... 20 mA, Terminals with test points, Up to SIL3 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 


20 ... 35 V DC, SIL/IEC 61508, Output signal: 0/4 ... 20 mA (overload > 25 mA), HART transfer, Dual output, Input, current source, Explosion 


protection: Ex input detail

KFD2-STC4-EX2 SMART Transmitter Power Supply, 2-channel isolated barrier, 24 V DC supply (Power Rail), 2-wire SMART transmitter, 


Output 4 mA ... 20 mA, Terminals with test points, Up to SIL2 acc. to IEC 61508, Input: 2-wire transmitter, Rated voltage: 20 ... 35 V DC, SIL/IEC 


61508, Output signal: 0/4 ... 20 mA (overload > 25 mA), HART transfer, Explosion protection: Ex input detail

Analog output

KFD2-CD-EX1.32 Current/Voltage Driver, 1-channel isolated barrier, 24 V DC supply (Power Rail), Current/voltage output up to 850 


Omega/3 Omega load, Factory configured input/output, Accuracy 0.1 %, Up to SIL2 acc. to IEC 61508, Rated voltage: 20 ... 35 V DC, SIL/IEC 


61508, Explosion protection: Ex-Output, Field circuit: 0(4)-20 mA, Safe area: 0(4)-20 mA, Transfer direction: to the field detail

KFD2-SCD2-Ex1.LK SMART Current Driver, 1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Omega load, 


HART I/P and valve positioner, Line fault detection (LFD), Accuracy 0.05 %, Terminals with test points, Up to SIL2 acc. to IEC 61508, Rated 


voltage: 10 ... 35 V DC, SIL/IEC 61508, HART transfer, Explosion protection: Ex-Output, Field circuit: 4-20 mA, HART, Safe area: 4-20 mA, HART, 


Transfer direction: to the field detail

KFD2-SCD2-EX1-Y1 SMART Current Driver, 1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Omega load, 


HART I/P and valve positioner, Lead breakage monitoring, Accuracy 0.05 %, Terminals with test points, Up to SIL2 acc. to IEC 61508, Rated 


voltage: 10 ... 35 V DC, SIL/IEC 61508, HART transfer, Explosion protection: Ex-Output, Field circuit: 4-20 mA, HART, Safe area: 4-20 mA, HART, 


Transfer direction: to the field detail

KFD2-SCD2-EX2.LK SMART Current Driver, 2-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Omega load, 


HART I/P and valve positioner, Line fault detection (LFD), Accuracy 0.05 %, Terminals with test points, Up to SIL2 acc. to IEC 61508, Rated 


voltage: 10 ... 35 V DC, SIL/IEC 61508, HART transfer, Explosion protection: Ex-Output, Field circuit: 4-20 mA, HART, Safe area: 4-20 mA, HART, 


Transfer direction: to the field detail

KFD2-SCD2-EX2-Y1 SMART Current Driver, 2-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Omega load, 


HART I/P and valve positioner, Lead breakage monitoring, Accuracy 0.05 %, Terminals with test points, Up to SIL2 acc. to IEC 61508, Rated 


voltage: 10 ... 35 V DC, SIL/IEC 61508, HART transfer, Explosion protection: Ex-Output, Field circuit: 4-20 mA, HART, Safe area: 4-20 mA, HART, 


Transfer direction: to the field detail

KFD2-VR2-Ex1.50M Voltage Repeater, 1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 mV ... +- 50 mV, Voltage output 


0 mV ... +- 50 mV, Selectable up/downscale burnout detection, Rated voltage: 15 ... 30 V DC, Explosion protection: Ex input, Field circuit: 0-50 


mV, Safe area: 0-50 mV, Transfer direction: to the control system detail

KFD2-VR4-Ex1.26 Voltage Repeater, 1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... -20 V, Vibration sensor 


inputs, Voltage/current field supply, Voltage output 0 V ... -20 V, Rated voltage: 20 ... 35 V DC, Explosion protection: Ex input, Field circuit: 0-20 


V, Safe area: 0-20 V detail

Digital input

KFD2-SH-Ex1 Safety Switch Amplifier, 1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 1 safety-


related relay output SIL3 acc. to IEC/EN 61508 and DIN VDE 0660, part 209, Product classification in accordance with ISO 13849-1 (EN 954-1, 


category 3), Line fault detection (LFD), Up to SIL3 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 20 ... 35 V DC, Output: relay, SIL/IEC 


61508, Explosion protection: Ex input detail

KFD2-SH-EX1.T.OP Switch Amplifier, 1-channel isolated barrier, 24 V DC supply (Power Rail), Input for dry contacts or SN Sensors, Active signal 


output, Relay contact output, Error message output, For usage in accordance with ISO 13849-1 (EN 954-1, category 3), Line fault detection 


(LFD), Up to SIL3 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 20 ... 30 V DC, Output: Transistor, SIL/IEC 61508, Explosion protection: 


Ex input detail

KFD2-SOT2-EX1.LB Switch Amplifier, 1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor 


output, non-polarized, Passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL2 acc. to IEC 


61508, Input: NAMUR sensor, Rated voltage: 20 ... 30 V DC, Output: Optocoupler, SIL/IEC 61508, Explosion protection: Ex input detail

KFD2-SOT2-EX2 Switch Amplifier, 2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor 


output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated 


voltage: 20 ... 30 V DC, Output: Optocoupler, SIL/IEC 61508, Explosion protection: Ex input detail

KFD2-SR2-Ex1.W Switch Amplifier, 1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact 


output, Line fault detection (LFD), Reversible mode of operation, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 20 ... 30 V 


DC, Output: relay, SIL/IEC 61508, Explosion protection: Ex input detail

KFD2-SR2-EX1.W.LB Switch Amplifier, 1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact 


output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL2 acc. to IEC 61508, Input: NAMUR 


sensor, Rated voltage: 20 ... 30 V DC, Output: relay, SIL/IEC 61508, Explosion protection: Ex input detail

KFD2-SR2-EX2.2S Switch Amplifier, 2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 x 2 relay contact 


outputs with AND logic, Line fault detection (LFD), Reversible mode of operation, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated 


voltage: 20 ... 30 V DC, Output: relay, SIL/IEC 61508, Explosion protection: Ex input detail

KFD2-SR2-Ex2.W Switch Amplifier, 2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact 


output, Line fault detection (LFD), Reversible mode of operation, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 20 ... 30 V 


DC, Output: relay, SIL/IEC 61508, Explosion protection: Ex input detail

Digital output

KFD0-SD2-Ex1.1045 Solenoid Driver, 1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 10 V DC, Up to SIL3 acc. 


to IEC 61508, Rated voltage: loop powered, SIL/IEC 61508, Explosion protection: Ex-Output, Output rated operating current: 45 mA


detail

KFD2-SL2-EX2 Solenoid Driver, 2-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-


polarized, Lead monitoring, Up to SIL2 acc. to IEC 61508, Input: with prelogic, Rated voltage: 20 ... 30 V DC, SIL/IEC 61508, Explosion 


protection: Ex-Output, Fault message output, Output rated operating current: 45 mA detail

KFD2-SL2-EX2.B Solenoid Driver, 2-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-


polarized, Up to SIL2 acc. to IEC 61508, Input: with prelogic, Rated voltage: 20 ... 30 V DC, SIL/IEC 61508, Explosion protection: Ex-Output, 


Output rated operating current: 45 mA detail

KFD0-RSH-1.4S.PS2 Relay Module, 1-channel signal conditioner, 24 V DC supply (loop powered), Fail-safe relay contact output for de-


energized and energized to safe function , Logic input 20 V DC ... 26.5 V DC, non-polarized, Immune to DCS test pulses (Yokogawa), Up to SIL3 


acc. to IEC 61508 detail

Temperature

KFD2-UT2-Ex1 Universal Temperature Converter, 1-channel isolated barrier, 24 V DC supply (Power Rail), TC, RTD, potentiometer or 


voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware TM, Line fault (LFD) and sensor burnout 


detection, Up to SIL2 acc. to IEC 61508, Input: Temperature, Rated voltage: 20 ... 30 V DC, Output: 4-20 mA, Explosion protection: Ex input


detail

KFD2-UT2-Ex2 Universal Temperature Converter, 2-channel isolated barrier, 24 V DC supply (Power Rail), TC, RTD, potentiometer or 


voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware TM, Line fault (LFD) and sensor burnout 


detection, Up to SIL2 acc. to IEC 61508, Input: Temperature, Rated voltage: 20 ... 30 V DC, Output: 4-20 mA, Explosion protection: Ex input


detail

KCD2-RR-EX1 Thermometer Resistance Repeater, 1-channel isolated barrier, 24 V DC supply (Power Rail), RTD/resistance input, 


Resistance output, Accuracy 0.1 %, Rated voltage: 20 ... 35 V DC, Explosion protection: Ex input, Field circuit: Resistance, Safe area: Resistance, 


Transfer direction: to the control system detail

Surge Protection

P-LB-1.A.13 1-channel, Plugs directly in to field side of KF modules, Analog or digital signal inputs, Surge protection up to 10 kA, 


Protects terminals 1 and 3 of KF modules, Uninterruptable operation (auto reset) detail

P-LB-1.B.12 1-channel, Plugs directly in to field side of KF modules, Analog or digital signal inputs, Surge protection up to 10 kA, 


Protects terminals 1 and 2 of KF modules, Uninterruptable operation (auto reset) detail

P-LB-1.C.123 1-channel, Plugs directly in to field side of KF modules, Analog or digital signal inputs, Surge protection up to 10 kA, 


Protects terminals 1, 2 and 3 of KF modules, Uninterruptable operation (auto reset) detail

P-LB-1.D.1234 1-channel, Plugs directly in to field side of KF modules, Analog or digital signal inputs, Surge protection up to 10 kA, 


Protects terminals 1, 2, 3 and 4 of KF modules, Uninterruptable operation (auto reset) detail

P-LB-1.E.23 1-channel, Plugs directly in to field side of KF modules, Analog or digital signal inputs, Surge protection up to 10 kA, 


Protects terminals 2 and 3 of KF modules, Uninterruptable operation (auto reset) detail

P-LB-1.F.1236 1-channel, Plugs directly in to field side of KF modules, Analog or digital signal inputs, Surge protection up to 10 kA, 


Protects terminals 1, 2, 3 and 6 of KF modules, Uninterruptable operation (auto reset) detail

P-LB-2.A.1346 2-channel, Plugs directly in to field side of KF modules, Analog or digital signal inputs, Surge protection up to 10 kA, 


Protects terminals 1, 3, 4 and 6 of KF module, Uninterruptable operation (auto reset) detail

P-LB-2.B.1245 2-channel, Plugs directly in to field side of KF modules, Analog or digital signal inputs, Surge protection up to 10 kA, 


Protects terminals 1, 2, 4 and 5 of KF module, Uninterruptable operation (auto reset) detail

P-LB-2.C.2356 2-channel, Plugs directly in to field side of KF modules, Analog or digital signal inputs, Surge protection up to 10 kA, 


Protects terminals 2, 3, 5 and 6 of KF modules, Uninterruptable operation (auto reset) detail

P-LB-2.D.123456 2-channel, Plugs directly in to field side of KF modules, Analog or digital signal inputs, Surge protection up to 10 kA, 


Protects terminals 1, 2, 3, 4, 5 and 6 of KF modules, Uninterruptable operation (auto reset) detail

K-LB-1.30 1-channel, DIN rail mount module, For 30 V IS or Non-IS applications, Protects field or control circuit inputs, Surge protection up to 


10 kA, Provides 500 V DC of isolation, Uninterruptable operation (auto reset) detail

K-LB-1.30G 1-channel, DIN rail mount module, For 30 V IS or Non-IS applications, Protects field or control circuit inputs, Surge 


protection up to 10 kA, Uninterruptable operation (auto reset) detail

K-LB-2.30 2-channel, DIN rail mount module, For 30 V IS or Non-IS applications, Protects field or control circuit inputs, Surge protection up to 


10 kA, Provides 500 V DC of isolation, Uninterruptable operation (auto reset) detail

K-LB-2.30G 2-channel, DIN rail mount module, For 30 V IS or Non-IS applications, Protects field or control circuit inputs, Surge 


protection up to 10 kA, Uninterruptable operation (auto reset) detail