  • Rosemount 3051SFA 1/2/3/4/D-L/G/S-020/025/030/035-C/D-C/S/0-H/D/U-P/F-S Annubar Flow Meter Emerson

Rosemount 3051SFA 1/2/3/4/D-L/G/S-020/025/030/035-C/D-C/S/0-H/D/U-P/F-S Annubar Flow Meter Emerson

2018-07-04 11:41:20

Description:

Designed with built-in flow calculations for direct reporting of fully-compensated mass flow Patented T-shape sensor creates a fixed separation point for DP signal improvement over a wider flow rate ……

New Products

Orbinox VG SERIES 61 Slurry knife gate valve

Orbinox SERIES 61 (VG) model knife gate valve is a wafer type valve equipped with two metal reinforced rubber sleeves,designed for applications with abrasive slurries.

Crosby J-Series Direct Spring Pressure Relief Valves

J-Series valves provide high quality and dependable overpressure protection for air, gas, steam, vapor, liquid and two-phase applications in one simple design. Now available with two new to the world technologies, Balanced Diaphragm and Bellows Leak Detection.

Vanessa Series 30,000 Cryogenic Triple Offset Valve

The Vanessa Series 30,000 Cryogenic Triple Offset Valve is a virtually maintenance-free valve with tightness, operability and torque demand unaffected by cryogenic conditions and severe temperature fluctuations.

Sempell Model SOT High pressure steam safety valve

The Sempell Model SOT is a high-pressure steam safety valve designed for boiler protection and steam system safety.

Assortments

Description

Rosemount 3051SFA 1/2/3/4/D-L/G/S-020/025/030/035/040/050/060/070/080/100/120-C/D-C/S/0-H/D/U-P/F-S-1/2/3-T1/A1/A3/A6/D1/D3/D6-0/C/D-0-T/0-3/5/7-1/2/3-A/D/E/J/K-A/F/X Annubar Flow Meter Emerson Automation Solutions Measurement Instrumentation Pressure

 

The Rosemount 3051SFA Annubar Flow Meter is a no-equal solution with a patented, averaging pitot tube that delivers superior measurement accuracy over a wide flow range. This flow meter can measure multiple variables and is engineered with an integrated thermowell for temperature measurement. Its patented T-shaped sensor is capable of obtaining measurements via a single pipe penetration while maintaining a small profile in the pipe to reduce permanent pressure loss and increase energy savings.

 

Specifications

Warranty Up to 15-year limited warranty

Rangedown Up to 200:1 (14:1 flow turndown)

Measurement Range Up to 1000 inH2O (2,48 bar) differential, Up to 3626 psia (250,00 bar) absolute, Up to 3626 psig (250,00 bar) gage

Line Size 2 to 96 in. (50 to 2440 mm)

Output Differential pressure, static pressure, process temperature, scaled variable, mass flow, volumetric flow, energy flow

Communication Protocol 4-20 mA HART®, WirelessHART®, FOUNDATION™ Fieldbus

Process Wetted Material 316 SST, Alloy C-276

Diagnostics Basic Diagnostics, Power Advisory Diagnostics, Advanced Diagnostics

Certifications/Approvals SIL 2/3 certified to IEC 61508 by an independent 3rd party, NACE, hazardous location, see full specs for complete list of certifications

 

Features

Designed with built-in flow calculations for direct reporting of fully-compensated mass flow

Patented T-shape sensor creates a fixed separation point for DP signal improvement over a wider flow rate

Advanced diagnostics provide diagnostic coverage to detect abnormal process conditions and electrical loop issues

Callendar-Van Dusen sensor matching improves temperature accuracy enabling best-in-class flow calculations

Ultra for Flow performance class enables optimized flow measurement with a ±0.04% of reading accuracy

T-shape Annubar design features very low permanent pressure loss

Integral thermowell of sensor adds process temperature measurement without additional pipe penetrations

All-welded, SuperModule™ design offers industry-leading accuracy in harsh environments and applications

Flowmeters come fully configured, leak-tested and ready to install right out of the box for fast installation

Sensor stagnation zone positioned to reduce noise, measurement inaccuracies and keeps particulates from clogging

SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations

 

Similar model codes for your reference :

3051SFADG200ZCHFS2A1C003AAA1

3051SFADG140ZCHFS2A1C0031AA1

3051SFADL030ZSUPS1T1000032AA1A1MS

3051SFA1S025CCHPSIT100T31JA1A5RLQ4

3051SFADL060DCHPS2T100032AA1A3

 

If you have any question, please do not hesitate to contact with me online

Contact details :

Shirley Sun

Sales Engineer

HONGKONG XIEYUAN TECH CO., LIMITED

Add : 7-A16, Caishen Commercial Plaza, Hangkou Railway Station, Wuhan, China

M : +86-15172506760 (WhatsApp & Wechat) | T : +86-27-85309780  | F : +86-27-85309780

Email : Shirley@whxyauto.com     Skype : 169649423@qq.com

Web : www.hkxytech.com