YOKOGAWA Fieldbus Segment Indicator FVX110
2016-06-29 15:59:59
Description:
With the simple turn of a knob, the FVX110 field indicator displays data on up to 16 process values from FOUNDATION™ fieldbus devices. The easy to read LCD display with LED backlighting makes this a very user friendly instrument. In addition, PID function blocks as well as link master and software download functions are provided as standard FVX110 features.……
brand new and orginal. place of orgin:japan .MOQ:1 pic
New Products
FXT1-P37 Right Angle Milling Head
FXT1-P37 Right Angle Milling Head - HKXYTECH
FXT1-P24 Right Angle Milling Head
FXT1-P24 Right Angle Milling Head - HKXYTECH
FXT1-P18 Right Angle Milling Head
FXT1-P18 Right Angle Milling Head - HKXYTECH
FXT1-AC Fully Automatic Right Angle Milling Heads
FXT1-AC Fully Automatic Right Angle Milling Heads - HKXYTECH
Assortments
▶ Pressure Transmitter EJA
▶ Pressure Transmitters EJA-E
▶ Pressue Transmitter EJX
▶ Safety Instrumented System (SIS)
▶ Valve Positioners & Converters
▶ Field Mount Indicators
▶ Temperature Transmitters
▶ Magnetic Flowmeters
▶ Vortex Flowmeter
▶ Ultrasonic Flowmeters
▶ Coriolis Mass Flowmeters - ROTAMASS 3-Series
▶ Variable Area Flowmeters – Rotameters
▶ Device Smart Communicators
▶ PORTABLE AND HANDHELD INSTRUMENTS
▶ Distributed Control System (DCS)
▶ Process Analyzers
▶ Paperless Recorders
▶ Strip Chart Recorders
▶ Data Acquisition Equipment
▶ UT Series Temperature Controllers
▶ UP Series Program Controllers
▶ UM Series Digital Indicators with Alarms
▶ UT100 Series Temperature Controllers
▶ UD Series Manual Setters
▶ Limit Controllers
▶ YS Series Single-loop Controllers
Description
YOKOGAWA FVX110 Fieldbus Segment Indicator
With the simple turn of a knob, the FVX110 field indicator displays data on up to 16 process values from FOUNDATION™ fieldbus devices. The easy to read LCD display with LED backlighting makes this a very user friendly instrument. In addition, PID function blocks as well as link master and software download functions are provided as standard FVX110 features.
FEATURES:
- Interoperability Field instruments that comply with the FOUNDATION fieldbus specifications are fully interoperable; no longer is there a need for custom designed software to communicate with other devices. - Display of up to 16 process variables Up to 16 process variables from multiple field instruments can be displayed, significantly reducing instrumentation costs. Furthermore, support of the FOUNDATION fieldbus digital communications protocol enables the display of signal data from third-party fieldbus compliant field devices. - Full dot-matrix LCD with LED backlight The backlit full dot-matrix LCD clearly displays text and graphics such as bar graphs, a scroll bar, and icons that indicate the page turning direction and scroll knob turning direction. - Link master function The FVX110 supports a link master function that enables backup of network management and allows local control using field devices. - Function blocks To facilitate device diagnostics, two functions blocks each are provided for the multiple analog output (MAO), arithmetic (AR), and input selector (IS), and a single function block is provided for the following: signal characterizer (SC), integrator (IT), and PID. - Software download With this function, it is possible to download updates or upgrades to the FVX110 software. Typical uses of this function are the addition of function blocks and diagnostics for existing devices. - Self-diagnosis A reliable self-diagnostic function based on the NAMUR NE107 standard detects failures in the ambient temperature limit, communications, and hardware such as the LCD and amplifier assembly.
MODEL AND SUFFIX CODES:
Supply voltage | 9 to 32 V DC for general use, flame proof type, Type n, or nonincendive 9 to 24 V DC for intrinsically safe type Entity model 9 to 17.5 V DC for intrinsically safe type FISCO model |
Communication requirements | Supply voltage: 9 to 32 V DC Current draw: Steady state: 15 mA (max) Software download state: 24 mA (max) |
Ambient temperature limits | -20 to 70 deg C (-4 to 158 deg F) |
Ambient humidity limits | 0 to 100%RH |
LCD display | 84 column x 32 lines full dot matrix with LED backlight |
Display functions | Process value, unit, tag number, bar graph, page information, scrolling direction information, scroll bar |
Display scroll function | Single scroll and cyclic scroll(scan mode) |
Housing | Low copper cast aluminum alloy, ASTM CF-8M stainless steel |
Degrees of protection | IP67, NEMA4X |
Certificates | FM, CENELEC ATEX, CSA, and IECEx |
EMC conformity standard | EN61326-1 Class A, Table 2 (for use in industrial locations) |
Link master function | Supported |
Function blocks | MAO×2 (30 ms), IS×2 (30 ms), AR×2 (30 ms), PID×2 (45 ms), SC×1 (30 ms), IT×1 (30 ms) |
Functional specifications | Functional specifications for fieldbus communications conform to the standard specifications (H1) of FOUNDATION fieldbus. |
* FOUNDATION in “FOUNDATION fieldbus” and the logo mark of Fieldbus Foundation are registered trademarks of the Fieldbus Foundation. |