Non-Dispersive Infrared Gas Analyzers (NDIR) IR200-hkxytech
  • Non-Dispersive Infrared Gas Analyzers (NDIR) IR200

Non-Dispersive Infrared Gas Analyzers (NDIR) IR200

2016-05-26 15:39:57

Description:

The IR200 infrared gas analyzer is capable of measuring the concentrations of CO2, CO, CH4, SO2, NO and O2 components in sample gas. CO2, CO, CH4, SO2 and NO are measured by the non-dispersive infrared method (NDIR), while O2 is measured by the paramagnetic or zirconia method. A maximum of 4 components including O2 (up to 3 components except for O2 measurement) are simultaneously measurable. A high-sensitivity mass flow sensor is adopted in the detection unit for the infrared method. Due to use of a single beam system for measurement, maintenance is easy and excellent stability is ensured for a long period of time. In addition, the IR200 has a large-size liquid crystal display, providing easy operation, high accuracy and multiple functions. This analyzer is thus optimum for combustion control of various industrial furnaces, botanical study and global atmospheric research.……

Notice:

New Products

Honeywell Analytics SPSTAXH1SS Sensepoint Flammable and Toxic Gas Detector Explosion-Proof Transmitters

Cost-effective, fixed point gas detector for the protection of personnel and plant from flammable, toxic and Oxygen gas hazards

Honeywell Analytics Sensepoint XCD RTD Remote toxic and oxygen gas detector for industrial applications

3 wire, 4-20mA and RS485 MODBUS output fixed point detector with in-built alarm and fault relays for the protection of personnel and plant from toxic and oxygen hazards.

Honeywell Analytics Sensepoint XCD RFD Remote Flammable Gas Monitor Explosion-Proof Transmitters

3-wire, 4-20mA, transmitter with optional Modbus for use with remotely mounted flammable gas sensors 705 and 705HT

Assortments

Description

IR200

The IR200 infrared gas analyzer is capable of measuring the concentrations of CO2, CO, CH4, SO2, NO and O2 components in sample gas. CO2, CO, CH4, SO2 and NO are measured by the non-dispersive infrared method (NDIR), while O2 is measured by the paramagnetic or zirconia method. A maximum of 4 components including O2 (up to 3 components except for O2 measurement) are simultaneously measurable.

A high-sensitivity mass flow sensor is adopted in the detection unit for the infrared method. Due to use of a single beam system for measurement, maintenance is easy and excellent stability is ensured for a long period of time. In addition, the IR200 has a large-size liquid crystal display, providing easy operation, high accuracy and multiple functions.

This analyzer is thus optimum for combustion control of various industrial furnaces, botanical study and global atmospheric research.

A high-sensitivity mass flow sensor is adopted in the detection block for the infrared method. Due to use of a single beam system for measurement, maintenance is easy and excellent stability is ensured for a long period of time. In addition, a microprocessor is built in and a large-size liquid crystal display is provided for easier operation, higher accuracy and more functions.

This analyzer is thus optimum for combustion control of various industrial furnaces, botanical study and global atmospheric research.

  • Simultaneous measurement of 4 components including O2

  • Excellent long-term stability

  • Subdued interference from other gas components

  • Easy to maintain

  • Easy to operate

  • Abundant functions