Description:

YOKOGAWA Analog Input Module AAI141 Current/Voltage Input Modules (Non-Isolated) These modules provide 16 inputs of mainly 4 to 20 mA DC or 1 to 5 V DC standardized signals from 2-wire/4-wire transmitters. They can be used in dual-redundant configuration.……

Notice:
EXW China Term; Coutry of Origin: Indonesia;

New Products

Siemens 6RA8025-6DS22-0AA0 SINAMICS DCM DC converter

SINAMICS DCM DC converter for two-quadrant drives B6C connection Input: 400V 3AC, 50 A controllable: Field rectifier D485/60 MRE-GEE6S22 Output: 485 V DC, 60A

Rosemount 2051L2AA0FD21AAM5DFQ4 Level Transmitter Emerson Automation Measurement Instrumentation Level

Gain confidence with the reliable performance of the Rosemount 2051L Level Transmitter, a transmitter that provides level measurements with a variety of process connections, materials and output protocols.

Rosemount 2051TG3A2C1DB4M5I5 In-Line Pressure Transmitter Emerson Measurement Instrumentation Pressure

Work more efficiently with the Rosemount 2051 In-Line Pressure Transmitter, an industry standard device that delivers reliable process data.

Rosemount 2051CG2A22A1AB4M5K7Q4Q Coplanar Pressure Transmitter Emerson Measurement Instrumentation Pressure

The Rosemount 2051 Coplanar Pressure Transmitter is industry-standard for differential and gage measurements.

Assortments

Description

YOKOGAWA Analog Input Module AAI143

STANDARD SPECIFICATIONS of AAI143

  Current/Voltage Input Modules (Non-Isolated)
  These modules provide 16 inputs of mainly 4 to 20 mA DC or 1 to 5 V DC standardized signals from 2-wire/4-wire transmitters.
  They can be used in dual-redundant configuration.

    

     

     Current Input Modules (Isolated)

     AAI143 provides 16 inputs of 4 to 20 mA signal. It can be used in dual-redundant configuration.

 

ItemsSpecifications
ModelAAI143 (*1)
Number of input channels16, isolated
Input signal4 to 20 mA
Allowable input current24 mA
Input resistancePower ON 270 Ω (20 mA) to 350 Ω (4 mA) (*2)

Power OFF 500 kΩ or larger
Accuracy±16 μA
Data update period10 ms
Transmitter power supply19.0 V or higher (at 20 mA) 25.5 V or less (at 0 mA) (output current limit: 25 mA) (*5)
Setting of 2-wire or 4-wire transmitterFor each channel by setting pin
Drift due to ambient temperature change±16 μA/10 C
Maximum current consumption230 mA (5 V DC), 540 mA (24 V DC)
Weight0.3 kg
External communicationPressure clamp terminal, MIL connector cable, dedicated cable (KS1)
HART communication (*3)Available


 

*1: A Zener barrier is not allowed to be connected with this module. Use an isolation barrier when the module is used in
intrinsically safe application.
*2: The module input resistance viewed from the terminals depends on the current strength as calculated as below:
250 Ω +
current value
voltage drop in the input protection circuit
F04E.ai
*3: When this module is installed to a ER bus node unit with HART function, the EB401 firmware must be rev. 2 or later.
*4: When the dedicated cable is used, the withstanding voltage is 500 V AC (between the input signal and the system). When
the ML connector cable is used, the withstanding voltage depends on the electrical specifications of the cable.
*5: This voltage is generated between the connecting terminals for 2-wire transmitters for this module. When calculating the
minimum operating voltage for transmitters, consider to allow margins for voltage drop in external wiring.

 

 

 

 

Yokogawa DCS Module AAI143  

 

EXTERNAL DIMENSIONS of AAI143

 

Yokogawa DCS Module AAI143   

MODEL AND SUFFIX CODES AAI143



Description
ModelAAI143   Analog Input Module (4 to 20 mA, 16-channel, Isolated)

-SStandard Type

-HWith digital communication (HART protocol)
Suffix
Codes
   5With no explosion protection

   EWith explosion protection

      0Basic type

      3With ISA Standard G3 option and temperature (-20 to 70 °C) option
Option
Codes
/K4A00With KS Cable Interface Adapter [Model : ATK4A-00]

/A4S00With Pressure Clamp Terminal Block for Analog [Model : ATA4S-00]

/A4S10With Pressure Clamp Terminal Block for Analog (surge absorber) [Model : ATA4S-10]

/A4D00With Dual Pressure Clamp Terminal Block for Analog [Model : ATA4D-00]

/A4D10With Dual Pressure Clamp Terminal Block for Analog (surge absorber) [Model : ATA4D-10]

/CCC01With Connector Cover for MIL Cable [Model : ACCC01]

 

AAI141  Analog Input Module (4 to 20 mA, 16-channel, Non-Isolated)

 

AAI141-S50/K4A00, AAI141-S50/A4S00, AAI141-S50/A4S10, AAI141-S50/A4D00, AAI141-S50/A4D10, AAI141-S50/CCC01,

AAI141-S53/K4A00, AAI141-S53/A4S00, AAI141-S53/A4S10, AAI141-S53/A4D00, AAI141-S53/A4D10, AAI141-S53/CCC01,

AAI141-SE0/K4A00, AAI141-SE0/A4S00, AAI141-SE0/A4S10, AAI141-SE0/A4D00, AAI141-SE0/A4D10, AAI141-SE0/CCC01,

AAI141-SE3/K4A00, AAI141-SE3/A4S00, AAI141-SE3/A4S10, AAI141-SE3/A4D00, AAI141-S53/A4D10, AAI141-S53/CCC01, 

AAI141-H50/K4A00, AAI141-H50/A4S00, AAI141-H50/A4S10, AAI141-H50/A4D00, AAI141-h50/A4D10, AAI141-H50/CCC01,

AAI141-H53/K4A00, AAI141-H53/A4S00, AAI141-H53/A4S10, AAI141-H53/A4D00, AAI141-h53/A4D10, AAI141-H53/CCC01,

AAI141-HE0/K4A00, AAI141-HE0/A4S00, AAI141-HE0/A4S10, AAI141-HE0/A4D00, AAI141-HE0/A4D10, AAI141-HE0/CCC01,

AAI141-HE3/K4A00, AAI141-HE3/A4S00, AAI141-HE3/A4S10, AAI141-HE3/A4D00, AAI141-HE3/A4D10, AAI141-HE3/CCC01,

 

AAV141  Analog Input Module (1 to 5 V, 16-channel, Non-Isolated)

AAV141-S50/K4A00, AAV141-S50/A4S00, AAV141-S50/A4S10, AAV141-S50/A4D00, AAV141-S50/A4D10, AAV141-S50/CCC01, 

AAI141-S53/K4A00, AAV141-S53/A4S00, AAV141-S53/A4S10, AAV141-S53/A4D00, AAV141-S53/A4D10, AAV141-S53/CCC01, 

AAV141-SE0/K4A00, AAV141-SE0/A4S00, AAV141-SE0/A4S10, AAV141-SE0/A4D00, AAV141-SE0/A4D10, AAV141-SE0/CCC01, 

AAV141-SE3/K4A00, AAV141-SE3/A4S00, AAV141-SE3/A4S10, AAV141-SE3/A4D00, AAV141-S53/A4D10, AAV141-S53/CCC01,

AAV141-H50/K4A00, AAV141-H50/A4S00, AAV141-H50/A4S10, AAV141-H50/A4D00, AAV141-h50/A4D10, AAV141-H50/CCC01,

AAV141-H53/K4A00, AAV141-H53/A4S00, AAV141-H53/A4S10, AAV141-H53/A4D00, AAV141-h53/A4D10, AAV141-H53/CCC01,

AAV141-HE0/K4A00, AAV141-HE0/A4S00, AAV141-HE0/A4S10, AAV141-HE0/A4D00, AAV141-HE0/A4D10, AAV141-HE0/CCC01,

AAV141-HE3/K4A00, AAV141-HE3/A4S00, AAV141-HE3/A4S10, AAV141-HE3/A4D00, AAV141-HE3/A4D10, AAV141-HE3/CCC01,

 

AAV142   Analog Input Module (-10 to +10 V, 16-channel, Non-Isolated)

AAV142-S50/K4A00, AAV142-S50/A4S00, AAV142-S50/A4S10, AAV142-S50/A4D00, AAV142-S50/A4D10, AAV142-S50/CCC01,

AAV142-S53/K4A00, AAV142-S53/A4S00, AAV142-S53/A4S10, AAV142-S53/A4D00, AAV142-S53/A4D10, AAV142-S53/CCC01,

AAV142-SE0/K4A00, AAV142-SE0/A4S00, AAV142-SE0/A4S10, AAV142-SE0/A4D00, AAV142-SE0/A4D10, AAV142-SE0/CCC01,

AAV142-SE3/K4A00, AAV142-SE3/A4S00, AAV142-SE3/A4S10, AAV142-SE3/A4D00, AAV142-S53/A4D10, AAV142-S53/CCC01, 

AAV142-H50/K4A00, AAV142-H50/A4S00, AAV142-H50/A4S10, AAV142-H50/A4D00, AAV142-h50/A4D10, AAV142-H50/CCC01,

AAV142-H53/K4A00, AAV142-H53/A4S00, AAV142-H53/A4S10, AAV142-H53/A4D00, AAV142-h53/A4D10, AAV142-H53/CCC01, 

AAV142-HE0/K4A00, AAV142-HE0/A4S00, AAV142-HE0/A4S10, AAV142-HE0/A4D00, AAV142-HE0/A4D10, AAV142-HE0/CCC01,

AAV142-HE3/K4A00, AAV142-HE3/A4S00, AAV142-HE3/A4S10, AAV142-HE3/A4D00, AAV142-HE3/A4D10, AAV142-HE3/CCC01,

 

AAB141  Analog Input Module (1 to 5 V/4 to 20 mA, 16-channel, Non-Isolated)

AAB141-H50/K4A00, AAB141-H50/K4A00, AAB141-H50/K4A00, AAB141-H50/ K4A00, AAB141-h50/K4A00, AAB141-H50/K4A00,

AAB141-H53/K4A00, AAB141-H53/ K4A00, AAB141-H53/ K4A00, AAB141-H53/ K4A00, AAB141-h53/ K4A00, AAB141-H53/ K4A00,

AAB141-HE0/K4A00, AAB141-HE0/K4A00, AAB141-HE0/K4A00, AAB141-HE0/K4A00, AAB141-HE0/K4A00, AAB141-HE0/K4A00,

AAB141-HE3/K4A00, AAB141-HE3/K4A00, AAB141-HE3/K4A00, AAB141-HE3/K4A00, AAB141-HE3/K4A00, AAB141-HE3/K4A00