YOKOGAWA Control Bus Interface Card VF702-hkxytech
  • YOKOGAWA Control Bus Interface Card VF702
  • YOKOGAWA Control Bus Interface Card VF702

YOKOGAWA Control Bus Interface Card VF702

2015-06-23 15:36:48

Description:

YOKOGAWA Control Bus Interface Card VF702 By installing the control bus interface card into the PCI Express slot of the PC/AT compatible computer, the computer is connected to V net.……

Notice:
EXW term; Origin: Singapore;

New Products

Honeywell Analytics SPSTAXH1SS Sensepoint Flammable and Toxic Gas Detector Explosion-Proof Transmitters

Cost-effective, fixed point gas detector for the protection of personnel and plant from flammable, toxic and Oxygen gas hazards

Honeywell Analytics Sensepoint XCD RTD Remote toxic and oxygen gas detector for industrial applications

3 wire, 4-20mA and RS485 MODBUS output fixed point detector with in-built alarm and fault relays for the protection of personnel and plant from toxic and oxygen hazards.

Honeywell Analytics Sensepoint XCD RFD Remote Flammable Gas Monitor Explosion-Proof Transmitters

3-wire, 4-20mA, transmitter with optional Modbus for use with remotely mounted flammable gas sensors 705 and 705HT

Assortments

Description

YOKOGAWA Control Bus Interface Card VF702

Model VF702 Control Bus Interface Card (for V net)


GENERAL

By installing the control bus interface card into the PCI Express slot of the PC/AT compatible computer, the computer is connected to V net.


FUNCTION

Interface between the PCI Express and V net


SPECIFICATIONS

Connection Specifications

Connection method: Connect a coaxial cable with

Model YCB146, T-type connector

Transmission: 10BASE-2 compliance

Connector: BNC connector

Max. distance: 185 m (When using 10BASE-2 cable only)

PCI Express Specifications

Applicable revision: PCI Express CEM Specification 1.0a x1, 2.5 GT/s signaling

This card can be installed in any of the PCI Express slots x1 to x16.

This card cannot be installed in a PCI slot.

Voltage

Power supply voltage: 3.3 V ± 9 %

Current Consumption

Max. 2.4 A

Weight: Approx. 0.15 kg (T-type connector excluded)

External Dimensions

22 (W) × 126.5 (H) × 193.54 (D) mm

Regulartory Compliance

For conforming standards of the CENTUM VP system,

see “System Overview” (GS 33K01A20-50E).

EMC Standards:

[CE Marking]

[C-Tick Marking]

[KC Marking]


PARTS NAME AND FUNCTIONS

RCV lamp

Lights when it detects signals on a control bus.

SND lamp

Lights when it sends signals to a control bus.

BNC connector

Connects a T-type connector on a control bus.


COMPATIBILITY WITH VF701

The V net interface of VF702 is compatible with that of VF701, so that a mixture of VF701-installed stations and

VF702-installed stations is allowed on the same control bus.

Setting the domain number and station number of a VF702 card can be performed in a same way as for a VF701

card.


MODEL AND SUFFIX CODE

Model Description

VF702 Control Bus Interface Card