Top Industrial Automation and Electrical Instrument from HKXYTECH
  • Fluke 8845A/8846A 6.5 Digit Precision Multimeters Precision measurement Bench instruments

Fluke 8845A/8846A 6.5 Digit Precision Multimeters Precision measurement Bench instruments

2019-01-03 16:14:20

Description:

8845A: 0.0035 + 0.0005 (% measurement + % of range) 8846A: 0.0024 + 0.0005 (% measurement + % of range) ……

New Products

Siemens 6DL1193-6TP00-0DH1 SIMATIC ET 200SP HA

Siemens 6DL1193-6TP00-0DH1 SIMATIC ET 200SP HA, Terminal block, Type H1, 32 push-in terminals, internal reference temperature New load group, width: 22.5 mm.

Siemens 6DL1193-6TP00-0BH1 SIMATIC ET 200SP HA

Siemens 6DL1193-6TP00-0BH1 SIMATIC ET 200SP HA, Terminal block, Type H1, 32 push-in terminals, internal reference temperature Width: 22.5 mm.

Siemens 6DL1193-6GC00-0NN0 SIMATIC ET 200SP HA

Siemens 6DL1193-6GC00-0NN0 SIMATIC ET 200SP HA, carrier module 8-fold carrier for holding 8 I/O modules of the ET 200SP HA.

Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA

Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA, carrier module 2-fold carrier for holding 2 I/O modules of the ET 200SP HA.

Assortments

Description

Fluke 8845A/8846A 6.5 Digit Precision Multimeters Precision measurement Bench instruments

 

Technical   Specifications

Display

VFD dot matrix

Resolution

6.5 Digits

V DC

Range

100 mV to 1000 V

Max. resolution

100 nV

Accuracy

8845A: 0.0035 + 0.0005 (% measurement + %   of range)

8846A: 0.0024 + 0.0005 (% measurement + %   of range)

V AC

Range

8845A: 100 mV to 750 V

8846A: 100 mV to 1000 V

Max. resolution

100 nV

Accuracy

8845A: 0.06 + 0.03 (% measurement + % of   range)

8846A: 0.06 + 0.03 (% measurement + % of   range)

Frequency

3 Hz to 300 KHz

Resistance

2 x 4 Wire

Yes

Range

8845A: 100 Ω to 100 MΩ

8846A: 10 Ω to 1 GΩ

Max. resolution

8845A: 100 μΩ

8846A: 10 μΩ

Accuracy

8845A: 0.010 + 0.001 (% measurement + %   of range)

8846A: 0.010 + 0.001 (% measurement + %   of range)

A DC

Range

100 μA to 10 A

Max. resolution

100 pA

Accuracy

0.050 + 0.005 (% measurement + % of   range)

A AC

Range

8845A: 10 mA to 10 A

8846A: 100 mA to 10 A

Max. resolution

8845A: 10 nA

8846A: 100 pA

Accuracy

0.10 + 0.04 (% measurement + % of range)

Frequency

3 Hz to 10 kHz

Freq/period

Range

8845A: 3 Hz to 300 kHz

8846A: 3 Hz to 1 MHz

Max. resolution

1 μHz

Accuracy

0.01%

Continuity / diode test

Yes

Capacitance

Range

8846A: 1 nF to 0.1 F

Max. resolution

8846A: 1 pf

Accuracy

8846A: 1%

Temperature

Type

8846A: Platinum RTD

Range

8846A: -200°C to +600°

Max. resolution

8846A: 0.01°

Accuracy

8846A: 0.06°

Math functions

NULL, Min/Max/Average, Std Dev

dB/dBm

Yes

Advanced functions

Statistics/histogram

Yes

Trendplot

Yes

Limit test

Yes

Input output

USB memory

8846A: USB memory drive port

Real time clock

8846A: Yes

Interfaces

RS 232, IEE-488.2, Ethernet, USB (with   optional adaptor)

Programming languages/modes

8846A: SCPI (IEEE-488.2), Agilent 34401A,   Fluke 45

General   Specifications

Weight

3.6 kg (8.0 lbs)

Dimensions

88 x 217 x 297 mm (3.46 x 8.56 x 11.7 in)

Calibration documentation

17025 accredited report of calibration   included

Safety

Designed to comply with IEC   61010-1:2000-1, UL 61010-1A1, CAN/CSA-C22.2 No. 61010.1, CAT I 1000V/CAT II   600V

Warranty

Three years

 

Similar model codes for your reference :

Fluke 8845A 6.5 Digit Precision Multimeter

Fluke 8845A/SU 6.5 Digit Precision Multimeter

Fluke 8846A 6.5 Digit Precision Multimeter

Fluke 8846A/SU 6.5 Digit Precision Multimeter

 

If you have any question, please do not hesitate to contact with me online

Contact details :

Shirley Sun

Sales Engineer

HONGKONG XIEYUAN TECH CO., LIMITED

Add : 7-A16, Caishen Commercial Plaza, Hankou Railway Station, Wuhan, China

M : +86-15172506760 (WhatsApp & Wechat) | T : +86-27-85309780  | F : +86-27-85309780

Email : Shirley@whxyauto.com     Skype : 169649423@qq.com