Honeywell SPXCDASMTX4 ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter, 2 x M20 Entries, 1 x M25 Entry, painted 316SS-hkxytech
  • Honeywell SPXCDASMTX4 ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter, 2 x M20 Entries, 1 x M25 Entry, painted 316SS

Honeywell SPXCDASMTX4 ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter, 2 x M20 Entries, 1 x M25 Entry, painted 316SS

2018-03-08 14:48:20

Description:

Sensepoint XCD-RTD transmitter (use with oxygen and toxic Sensepoint sensors) Sensepoint XCD-RTD (Remote Toxic Detector) allows for a gas sensor from a wider selection of 2-wire 4 to 20 mA input type Toxic and Oxygen sensors to be fitted directly to the transmitter housing, or wired remotely from another location.……

Notice:
KIT includes Transmitter, Magnetic Wand and Allen Key

New Products

E+H e&h Endresss Hauser FMU30-AAHEABGHF Ultrasonic measurement Time-of-Flight Prosonic FMU30 are in stock

Field of application: Two-wire instrument for continuous non-contact level and flow measurement. Process connection: Thread Temperature: -20 to +60°C (-4 to +140°F) Pressure: +0.7 to +3bar (+10 to +44psi) Maximum measuring distance: Sensor 1½" for liquids 5m (16ft) and for bulk solids 2m (6.6ft), Sensor 2" for liquids 8m (26ft)and for bulk solids 3.5m (11ft) Blocking distance: Sensor 1½" 0.25m (0.8ft), Sensor 2" 0.35m (1.15ft) International explosion protection certificates

Endresss Hauser original Ultrasonic measurement Time-of-Flight Prosonic FMU90 with best price made in Germany FMU90-R11CA212AA3A

010 Approval: R Non-hazardous area 020 Application: 1 Level + pump control, alternating 030 Housing, Material: 1 Field mounting PC, IP66 NEMA4x 040 Operation: C Illuminated display + keypad 050 Power Supply: A 90-253VAC 060 Level Input: 1 1x sensor FDU9x/8x 070 Switch Output: 1 1x relay, SPDT 080 Output: 1 1x 0/4-20mA HART 090 Additional Input: A W/o 100 Datalog Function: A Basic version 110 Language: 3 EN, ZH, JA, KO, TH, ID 120 Additional Option: A Basic version

Endress Hauser 7F2C15-AAACCAABBAAACSKA1 Proline Prowirl F 200 Vortex flowmeter 7F2C15

Same accuracy down to Re 10000 –most linear Vortex meter body

Endress Hauser FMU30-AAHEAAGGF Ultrasonic Level Measurement Transmitter FMU30-AAHEAAGGF

Envelope curves on the on-site display for simple diagnosis

Assortments

Description

Honeywell SPXCDASMTX4 ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter, 2 x M20 Entries, 1 x M25 Entry, painted 316SS


Sensepoint XCD-RTD transmitter (use with oxygen and toxic Sensepoint sensors)


Sensepoint XCD-RTD (Remote Toxic Detector) allows for a gas sensor from a wider selection of 2-wire 4 to 20 mA input type Toxic and Oxygen sensors to be fitted directly to the transmitter housing, or wired remotely from another location. KIT includes Transmitter, Magnetic Wand and Allen Key

Sensepoint   XCD-RTD transmitter (use with oxygen and toxic Sensepoint sensors)
Sensepoint   XCD-RTD (Remote Toxic Detector) allows for a gas sensor from a wider   selection of 2-wire 4 to 20 mA input type Toxic and Oxygen sensors to be   fitted directly to the transmitter housing, or wired remotely from another   location. KIT includes Transmitter, Magnetic Wand and Allen Key
INSTRUMENT
Without   Modbus
SPXCDALMTX4   ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter, 2 x M20   Entries, 1 x M25 Entry, painted LM25
SPXCDASMTX4   ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter, 2 x M20   Entries, 1 x M25 Entry, painted 316SS
SPXCDULNTX4   cCSAus approved SP XCD-RTD 4~20mA Input Transmitter, 3 x 3/4'' NPT Entries,   painted LM25
SPXCDUSNTX4   cCSAus approved SP XCD-RTD 4~20mA Input Transmitter, 3 x 3/4'' NPT Entries,   painted 316SS
With   Modbus
SPXCDALMTX4M   ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter with   MODBUS, 2 x M20 Entries, 1 x M25 Entry, painted LM25
SPXCDASMTX4M   ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter with   MODBUS, 2 x M20 Entries, 1 x M25 Entry, painted 316SS
SPXCDULNTX4M   cCSAus approved SP XCD-RTD 4~20mA Input Transmitter with MODBUS, 3 x 3/4''   NPT Entries, painted LM25
SPXCDUSNTX4M   cCSAus approved SP XCD-RTD 4~20mA Input Transmitter with MODBUS, 3 x 3/4''   NPT Entries, painted 316SS
Note:   Refer to "Sensepoint" pricelist for the new M25 for ATEX/IECEx and   3/4''NPT for cCSA threaded range of Sensepoint Toxic sensors that may be   fitted directly to the 4-20mA input XCD-RTD transmitter.

Sensepoint   XCD-RFD transmitter (use with Standard & Hi-Temp Sensepoint sensors)
Sensepoint   XCD-RFD (Remote Flammable Detector) allows for remotely mounted flammable gas   detectors such as Hi-Temperature version of Sensepint Flamable to be located   in adverse applications and monitored from a convenient location. KIT   includes Transmitter, Magnetic Wand and Allen Key
INSTRUMENT
Without   Modbus
SPXCDALMRFD   ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor   input Transmitter, 2 x M20 Entries,1 x M25 Entry,painted LM25
SPXCDASMRFD   ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor   input Transmitter, 2 x M20 Entries,1 x M25 Entry,painted 316SS
SPXCDULNRFD   cCSAus approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input   Transmitter, 3 x 3/4'' NPT Entries, painted LM25
SPXCDUSNRFD   cCSAus approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input   Transmitter, 3 x 3/4'' NPT Entries, painted 316SS
With   Modbus
SPXCDALMRFDM   ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor   input Transmitter with MODBUS, 2 x M20 Entries, 1 x M25 Entry, paited LM25
SPXCDASMRFDM   ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor   input Transmitter with MODBUS, 2 x M20 Entries, 1 x M25 Entry, paited 316SS
SPXCDULNRFDM   cCSAus approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input   Transmitter with MODBUS, 3 x 3/4'' NPT Entries, painted LM25
SPXCDUSNRFDM   cCSAus approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input   Transmitter with MODBUS, 3 x 3/4'' NPT Entries, painted 316SS
Remote   Flammable Sensor (XCD Sensor Cartridge + Socket Housing)
SPXCDXSRFXSS   Flammable CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) Sensor Cartridge with   Socket Housing
SPXCDXSRRXSS   Methane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) Sensor Cartridge with Socket   Housing
SPXCDXSRPXSS   Propane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) Sensor Cartridge with Socket   Housing
SPXCDXSRB1SS   Carbon Dioxide IR 0-2.00%VOL only with Socket Housing Sensor Cartridge with   Socket Housing
SPXCDXSRB2SS   Carbon Dioxide IR 0-5.00%VOL only with Socket Housing Sensor Cartridge with   Socket Housing
00780-A-0100   Term Hsg-Bartec DE1155 With Continuity Plate 1x25mm- 3x20mm Entries (ATEX   certified)